Bearing Capacity of Rectangular Foundations near the Slopes with Nonassociated Flow Rules

A method of three-dimensional slope stability analysis is presented here based on the energy consideration to obtain the ultimate bearing capacity of rectangular foundations located near the slopes with coaxial nonassociated flow rule. Taking the eccentrically loaded foundation into account, a rotational failure mechanism consisted of several lateral surfaces is considered. The stress distribution along the rupture surface, needed to obtain the rate of dissipation of internal energy for the nonassociated flow rule, is established on the basis of extended Bishop's method and boussinesq theorem. The bearing capacity of rectangular foundations in different conditions is obtained using the proposed method and the effects of dilatancy angle are investigated. The results indicate that for the nonassociated flow rule materials, the bearing capacity of slopes reduces with decrease in the dilatancy angle. These influences increase in the case of mild slopes in frictional.

[1]  O. Hungr An extension of Bishop's simplified method of slope stability analysis to three dimensions , 1987 .

[2]  Radoslaw L. Michalowski,et al.  THREE-DIMENSIONAL ANALYSIS OF LOCALLY LOADED SLOPES , 1989 .

[3]  A. Bishop The use of the Slip Circle in the Stability Analysis of Slopes , 1955 .

[4]  P. de Buhan,et al.  THREE DIMENSIONAL BEARING CAPACITY ANALYSIS OF A FOUNDATION NEAR A SLOPE , 1998 .

[5]  Hisham T. Eid,et al.  PERFORMANCE OF THREE-DIMENSIONAL SLOPE STABILITY METHODS IN PRACTICE , 1998 .

[6]  Keizo Ugai,et al.  THREE-DIMENSIONAL STABILITY ANALYSIS OF VERTICAL COHESIVE SLOPES , 1985 .

[7]  F. Askari,et al.  Three-Dimensional Analysis of Nonhomogeneous Slopes , 2003 .

[8]  H. Hovland,et al.  THREE-DIMENSIONAL SLOPE STABILITY ANALYSIS METHOD , 1977 .

[9]  R. H. Chen,et al.  THREE-DIMENSIONAL LIMIT EQUILIBRIUM ANALYSIS OF SLOPES , 1983 .

[10]  Yang Xiao-li,et al.  Influences of nonassociated flow rules on seismic bearing capacity factors of strip footing on soil slope by energy dissipation method , 2007 .

[11]  W. B. Wei,et al.  Three-dimensional slope failure analysis by the strength reduction and limit equilibrium methods , 2009 .

[12]  Rong-Her Jimmy Chen,et al.  Three-Dimensional Slope Stability Analysis , 1981 .

[13]  A.P.S. Selvadurai,et al.  Influence of Nonassociativity on the Bearing Capacity of a Strip Footing , 2001 .

[14]  Raymond J. Krizek,et al.  Stability of Vertical Corner Cut with Concentrated Surcharge Load , 1976 .

[15]  F. Askari,et al.  Three-Dimensional Stability Analysis of Convex Slopes in Plan View , 2008 .

[16]  E. H. Davis,et al.  Theories of plasticity and the failure of soil masses , 1968 .

[17]  Emmanuel M Detournay,et al.  Limit load in translational failure mechanisms for associative and non-associative materials , 1993 .