A dedicated superbend x-ray microdiffraction beamline for materials, geo-, and environmental sciences at the advanced light source.

A new facility for microdiffraction strain measurements and microfluorescence mapping has been built on beamline 12.3.2 at the advanced light source of the Lawrence Berkeley National Laboratory. This beamline benefits from the hard x-radiation generated by a 6 T superconducting bending magnet (superbend). This provides a hard x-ray spectrum from 5 to 22 keV and a flux within a 1 microm spot of approximately 5x10(9) photons/s (0.1% bandwidth at 8 keV). The radiation is relayed from the superbend source to a focus in the experimental hutch by a toroidal mirror. The focus spot is tailored by two pairs of adjustable slits, which serve as secondary source point. Inside the lead hutch, a pair of Kirkpatrick-Baez (KB) mirrors placed in a vacuum tank refocuses the secondary slit source onto the sample position. A new KB-bending mechanism with active temperature stabilization allows for more reproducible and stable mirror bending and thus mirror focusing. Focus spots around 1 microm are routinely achieved and allow a variety of experiments, which have in common the need of spatial resolution. The effective spatial resolution (approximately 0.2 microm) is limited by a convolution of beam size, scan-stage resolution, and stage stability. A four-bounce monochromator consisting of two channel-cut Si(111) crystals placed between the secondary source and KB-mirrors allows for easy changes between white-beam and monochromatic experiments while maintaining a fixed beam position. High resolution stage scans are performed while recording a fluorescence emission signal or an x-ray diffraction signal coming from either a monochromatic or a white focused beam. The former allows for elemental mapping, whereas the latter is used to produce two-dimensional maps of crystal-phases, -orientation, -texture, and -strain/stress. Typically achieved strain resolution is in the order of 5x10(-5) strain units. Accurate sample positioning in the x-ray focus spot is achieved with a commercial laser-triangulation unit. A Si-drift detector serves as a high-energy-resolution (approximately 150 eV full width at half maximum) fluorescence detector. Fluorescence scans can be collected in continuous scan mode with up to 300 pixels/s scan speed. A charge coupled device area detector is utilized as diffraction detector. Diffraction can be performed in reflecting or transmitting geometry. Diffraction data are processed using XMAS, an in-house written software package for Laue and monochromatic microdiffraction analysis.

[1]  M. Kunz,et al.  The passivation of calcite by acid mine water. Column experiments with ferric sulfate and ferric chloride solutions at pH 2 , 2008 .

[2]  Andreas Scholl,et al.  Gradual ordering in red abalone nacre. , 2008, Journal of the American Chemical Society.

[3]  Gregory Y. Morrison,et al.  Performance of the upgraded LTP-II at the ALS Optical Metrology Laboratory , 2008, Optical Engineering + Applications.

[4]  Valeriy V. Yashchuk,et al.  New procedures for the adjustment of elliptically bent mirrors with the long trace profiler , 2007, SPIE Optical Engineering + Applications.

[5]  T. Ishikawa,et al.  Efficient focusing of hard x rays to 25nm by a total reflection mirror , 2007 .

[6]  J. R. Patel,et al.  Crystal plasticity in Cu damascene interconnect lines undergoing electromigration as revealed by synchrotron x-ray microdiffraction , 2006 .

[7]  N. Tamura,et al.  D075 4-D XRD for strain in many grains using triangulation , 2006, Powder Diffraction.

[8]  H. C. Kang,et al.  Nanometer linear focusing of hard x rays by a multilayer Laue lens. , 2006, Physical review letters.

[9]  N. Tamura,et al.  Micro scanning X-ray diffraction study of Gallo-Roman Terra Sigillata ceramics , 2006 .

[10]  A. Macrander,et al.  Short Focal Length Kirkpatrick-Baez Mirrors for a Hard X-Ray Nanoprobe , 2005 .

[11]  P. Cloetens,et al.  Efficient sub 100 nm focusing of hard x rays , 2005 .

[12]  N. Tamura,et al.  Electromigration-induced microstructure evolution in tin studied by synchrotron x-ray microdiffraction , 2004 .

[13]  K. Tu Recent advances on electromigration in very-large-scale-integration of interconnects , 2003 .

[14]  M. Kawamura,et al.  Nanowires and nanorings at the atomic level. , 2003, Physical review letters.

[15]  J. R. Patel,et al.  Scanning X-ray microdiffraction with submicrometer white beam for strain/stress and orientation mapping in thin films. , 2003, Journal of synchrotron radiation.

[16]  A. A. MacDowell,et al.  Electromigration-induced plastic deformation in passivated metal lines , 2002 .

[17]  Wenge Yang,et al.  Three-dimensional X-ray structural microscopy with submicrometre resolution , 2002, Nature.

[18]  H. Padmore,et al.  Theory and practice of elliptically bent x-ray mirrors , 2000 .

[19]  King-Ning Tu,et al.  Effect of current crowding on vacancy diffusion and void formation in electromigration , 2000 .

[20]  Z. Ren,et al.  Quantitative Analysis of Synchrotron Laue Diffraction Patterns in Macromolecular Crystallography , 1995 .

[21]  John R. Helliwell,et al.  The recording and analysis of synchrotron X-radiation Laue diffraction photographs , 1989 .

[22]  J. Nye Physical Properties of Crystals: Their Representation by Tensors and Matrices , 1957 .

[23]  Nicolas Geoffroy,et al.  Molecular-scale speciation of Zn and Ni in soil ferromanganese nodules from loess soils of the Mississippi Basin. , 2003, Environmental science & technology.