Signal Path Loss Simulation of Human Arm for Galvanic Coupling Intra-Body Communication Using Circuit and Finite Element Method Models

Galvanic coupling intra-body communication involves the formation of a network between small terminals applied to the surface of the human body and bio-signal sensors embedded within the body. To enable the design of a communication device, it is important to fully understand the signal transmission loss characteristics of the human body, while developing a method that optimizes the transmission efficiency. This study analyzed the signal path loss during galvanic-coupling intra-body communication of a human arm through the application of a four-terminal circuit and a finite-element method (FEM) model, with special attention given to the return path. The effect of the interface circuit of an LC series -- parallel circuit that injected the signal into the human body was also examined. Without the LC series-parallel circuit, the attenuation of the transmitted signal was minimized within a range of 2-5 MHz in the circuit model and 3-7 MHz in the FEM model. The addition of the LC series-parallel circuit improved the attenuation by 1.9-5.8 dB at the resonant frequency (2 MHz).

[1]  Michael Faulkner,et al.  A Survey on Intrabody Communications for Body Area Network Applications , 2013, IEEE Transactions on Biomedical Engineering.

[2]  A. Sasaki,et al.  Sensitive and stable electro-optic sensor for intrabody communication , 2004, The 17th Annual Meeting of the IEEELasers and Electro-Optics Society, 2004. LEOS 2004..

[3]  Peng Un Mak,et al.  A multilayer cylindrical volume conductor model for galvanic coupling intra-body communication , 2009, 2009 7th International Conference on Information, Communications and Signal Processing (ICICS).

[4]  Wolfgang Fichtner,et al.  An Attempt to Model the Human Body as a Communication Channel , 2007, IEEE Transactions on Biomedical Engineering.

[5]  H. Hosaka,et al.  Simplified circuit modeling and fabrication of intrabody communication devices , 2005, The 13th International Conference on Solid-State Sensors, Actuators and Microsystems, 2005. Digest of Technical Papers. TRANSDUCERS '05..

[6]  Masaharu Takahashi,et al.  Simplified circuit modeling and fabrication of intrabody communication devices , 2006 .

[7]  Eiji Okamoto,et al.  Interface of data transmission for a transcutaneous communication system using the human body as transmission medium , 2011, Journal of Artificial Organs.

[8]  Mario Cifrek,et al.  A finite element method study of the current density distribution in a capacitive intrabody communication system , 2010 .

[9]  Javier Reina-Tosina,et al.  Distributed Circuit Modeling of Galvanic and Capacitive Coupling for Intrabody Communication , 2012, IEEE Transactions on Biomedical Engineering.

[10]  Kai Zhang,et al.  The Simulation Method of the Galvanic Coupling Intrabody Communication With Different Signal Transmission Paths , 2011, IEEE Transactions on Instrumentation and Measurement.

[11]  Thomas G. Zimmerman,et al.  : Near-field , 2022 .

[12]  Michael Faulkner,et al.  Investigation of Galvanic-Coupled Intrabody Communication Using the Human Body Circuit Model , 2014, IEEE Journal of Biomedical and Health Informatics.

[13]  Wolfgang Fichtner,et al.  Signal Transmission by Galvanic Coupling Through the Human Body , 2010, IEEE Transactions on Instrumentation and Measurement.