Improving image-guided target localization through deformable registration

Purpose. To quantify the improvements in online target localization using kV cone beam CT (CBCT) with deformable registration. Methods and material. Twelve patients treated under a 6 fraction liver cancer radiation therapy protocol were imaged in breath hold using kV CBCT at each treatment fraction. The images were imported into the treatment planning software and rigidly registered by fitting the liver, identified on the daily kV CBCT image, into the liver contours, previously drawn on the planning CT. The liver was then manually contoured on each CBCT image. Deformable registration was automatically performed, aligning the CT liver to the liver on each CBCT image using MORFEUS, a biomechanical model based deformable registration algorithm. The tumor, defined on planning CT, was mapped onto the CBCT, through MORFEUS. The center of mass (COM) displacement of the tumor was computed. Results. The mean (SD) displacement magnitude (absolute value) of the COM following deformable registration was 0.08 (0.07), 0.10 (0.11), and 0.10 (0.17) cm in the left-right (LR), anterior-posterior (AP), and superior-inferior (SI) directions, respectively. The maximum displacement of the COM was 0.34, 0.65, and 0.97 cm in the LR, AP, and SI directions, respectively. Fifteen percent of the treatment fractions had a COM displacement of greater than 0.3 cm and 33% of patients had at least 1 fraction with a displacement of greater than 0.3 cm. The deformable registration, excluding the manual contouring of the liver, was performed in less than 1 minute, on average. Discussion. Rigid registration of the liver volume between planning CT and verification kV CBCT localizes the tumor to within 0.3 cm for the majority (66%) of patients; however, larger offsets in tumor position can be observed due to liver deformation.

[1]  C C Ling,et al.  Cone-beam CT with megavoltage beams and an amorphous silicon electronic portal imaging device: potential for verification of radiotherapy of lung cancer. , 2002, Medical physics.

[2]  Sarang Joshi,et al.  Large deformation three-dimensional image registration in image-guided radiation therapy , 2005, Physics in medicine and biology.

[3]  S. Joshi,et al.  Automatic Segmentation of Intra-treatment CT Images for Adaptive Radiation Therapy of the Prostate , 2005, MICCAI.

[4]  Hyunjin Park,et al.  Construction of an abdominal probabilistic atlas and its application in segmentation , 2003, IEEE Transactions on Medical Imaging.

[5]  Randall K Ten Haken,et al.  Daily prostate targeting using implanted radiopaque markers. , 2001, International journal of radiation oncology, biology, physics.

[6]  J. Kapatoes,et al.  Megavoltage CT image reconstruction during tomotherapy treatments. , 2000, Physics in medicine and biology.

[7]  Kristy K Brock,et al.  Accuracy of daily image guidance for hypofractionated liver radiotherapy with active breathing control. , 2005, International journal of radiation oncology, biology, physics.

[8]  K. Brock,et al.  Feasibility of a novel deformable image registration technique to facilitate classification, targeting, and monitoring of tumor and normal tissue. , 2006, International journal of radiation oncology, biology, physics.

[9]  J H Siewerdsen,et al.  Cone-beam computed tomography with a flat-panel imager: initial performance characterization. , 2000, Medical physics.

[10]  He Wang,et al.  Use of deformed intensity distributions for on-line modification of image-guided IMRT to account for interfractional anatomic changes. , 2005, International journal of radiation oncology, biology, physics.

[11]  Paul A. Yushkevich,et al.  Multiscale deformable model segmentation and statistical shape analysis using medial descriptions , 2002, IEEE Transactions on Medical Imaging.

[12]  B G Fallone,et al.  A grey-level image alignment algorithm for registration of portal images and digitally reconstructed radiographs. , 1996, Medical physics.

[13]  R K Ten Haken,et al.  The reproducibility of organ position using active breathing control (ABC) during liver radiotherapy. , 2001, International journal of radiation oncology, biology, physics.

[14]  J Moseley,et al.  A semiautomatic method for registration of portal images. , 1994, Medical physics.

[15]  A L Boyer,et al.  An image correlation procedure for digitally reconstructed radiographs and electronic portal images. , 1995, International journal of radiation oncology, biology, physics.

[16]  J O Deasy,et al.  Tomotherapy: a new concept for the delivery of dynamic conformal radiotherapy. , 1993, Medical physics.

[17]  James M. Balter,et al.  A comparison of computer‐controlled versus manual on‐line patient setup adjustment , 2002, Journal of applied clinical medical physics.

[18]  David Jaffray,et al.  Assessment of residual error in liver position using kV cone-beam computed tomography for liver cancer high-precision radiation therapy. , 2006, International journal of radiation oncology, biology, physics.

[19]  J Troccaz,et al.  Patient set-up using portal images: 2D/2D image registration using mutual information. , 2000, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[20]  Maria Hawkins,et al.  Reproducibility of liver position using active breathing coordinator for liver cancer radiotherapy. , 2006, International journal of radiation oncology, biology, physics.

[21]  D A Jaffray,et al.  Accuracy of finite element model-based multi-organ deformable image registration. , 2005, Medical physics.

[22]  R. Kikinis,et al.  Automated segmentation of MR images of brain tumors. , 2001, Radiology.

[23]  Weiguo Lu,et al.  Deformable registration of the planning image (kVCT) and the daily images (MVCT) for adaptive radiation therapy , 2006, Physics in medicine and biology.

[24]  R L Ehman,et al.  Tissue characterization using magnetic resonance elastography: preliminary results. , 2000, Physics in medicine and biology.

[25]  Jon-Paul Voroney,et al.  Prospective comparison of computed tomography and magnetic resonance imaging for liver cancer delineation using deformable image registration. , 2006, International journal of radiation oncology, biology, physics.