Flow injection renewable surface immunoassay: a new approach to immunoanalysis with fluorescence detection.

This paper introduces a new methodology of carrying out heterogeneous immunoassays automatically, using a flow injection technique on a renewable surface. Flow injection renewable surface immunoassay (FIRSI) relies on the use of a minute amount of beads to form a reactive surface, which is interrogated by fluorescence spectrometry. Following the assay, on-line regeneration normally used in flow based immunoassays is avoided by fluidically removing the spent reactive surface and replacing it with a new layer of beads. This allows the monitoring of antibody-antigen binding at its early stages, dramatically increases the sampling frequency of a serial assay, and eliminates the problems associated with a decrease in surface reactivity caused by repetitive use. A model system utilizing anti-mouse IgG1-coated beads and mouse IgG1 protein is used to characterize the method with respect to reproducibility, flow rate, contact time, and amount of beads.

[1]  J Ruzicka,et al.  Sequential injection immunoassay utilizing immunomagnetic beads. , 1992, Analytical chemistry.

[2]  R. Warren,et al.  An assessment of the Kemble Star 700 sample processor for the automation of complement fixation and ELISA tests in a microbiology laboratory. , 1991, Journal of Medical Microbiology.

[3]  J. Gosling A decade of development in immunoassay methodology. , 1990, Clinical chemistry.

[4]  G W Kramer Integrating laboratory robots with analytical instruments--must it really be so difficult? , 1990, Clinical chemistry.

[5]  D. S. Hage,et al.  Theory of a sequential addition competitive binding immunoassay based on high-performance immunoaffinity chromatography. , 1993, Analytical chemistry.

[6]  F. Regnier,et al.  Kinetic chromatographic sequential addition immunoassays using protein A affinity chromatography. , 1992, Analytical chemistry.

[7]  Angel Montoya,et al.  A Comprehensive Overview on the Application of Flow Injection Techniques in Immunoanalysis , 1992 .

[8]  H. Nygren,et al.  Kinetics of antigen-antibody reactions at solid-liquid interfaces. , 1988, Journal of immunological methods.

[9]  J Ruzicka,et al.  Jet ring cell: a tool for flow injection spectroscopy and microscopy on a renewable solid support. , 1993, Analytical chemistry.

[10]  V E DeMoranville,et al.  Examples of enhanced laboratory workflow through the application of robotics. , 1990, Clinical chemistry.

[11]  H Håkanson,et al.  Process monitoring by flow-injection immunoassay. Evaluation of a sequential competitive binding assay. , 1992, Journal of chromatography.

[12]  S. Theander,et al.  A diffusion limited reaction theory for a microtiter plate assay. , 1988, Journal of immunological methods.

[13]  C. Shellum,et al.  Flow-injection immunoassays , 1993 .