Quantitative approach to control spinning stability of the impeller in the pivot bearing-supported centrifugal pump.

The Gyro C1E3 pump has been developed as a completely sealless centrifugal pump driven by a magnetic coupling system for long-term usage. The Gyro C1E3 pump is a pivot bearing-supported pump in which the impeller is supported with the top and bottom pivot bearings. In the Gyro C1E3 pump, the impeller spinning is affected by the force balance between the floating force (Ff[N]) of the hydrodynamic effect and the magnetic thrust force (Tf[N]). The authors quantitatively investigated the floating force of the impeller in vitro to determine the magnetic coupling distance (MCD[mm]) that would result in stable impeller spinning. In vitro tests were performed using a loop filled with 37% glycerin solution to obtain the relationship between the MCD and floating speed (Rf, rotational speed when the impeller starts floating [rpm]) and the relationship between the MCD and Tf. From the obtained relationships, we calculated Ff and determined the relationship between the Ff and the rotational speed (R). Furthermore, we determined the relationship between d (minimum required MCD [mm]) and R from the results of determining the relationship of the MCD and Tf and of the Ff and R. The following relationships were obtained: Rf = 6.24 x 10(4) x MCD-1.35; Tf = 5.27 x 10(3) x MCD-2.29; Ff = 4.71 x 10(-6) x RPM1.69; and d = 9.02 x RPM-0.85 where RPM is the rotational speed. It was demonstrated that the floating force of the impeller is a function only of the rotational speed in the pivot bearing-supported Gyro C1E3 pump. The floating force is estimated to be 10 N to 40 N at rotational speeds of 1,500 rpm to 3,000 rpm at which the Gyro pump may be used in most clinical situations. It would be possible to control the impeller position of the Gyro pump automatically at the stable spinning condition by controlling the adequate magnetic coupling distance based upon its relationship with the rotational speed which was obtained in this study.

[1]  Curtis Jj Centrifugal mechanical assist for postcardiotomy ventricular failure. , 1994 .

[2]  H. Nishida,et al.  Less platelet damage in the curved vane centrifugal pump: a comparative study with the roller pump in open heart surgery. , 1994, Artificial organs.

[3]  Y Nosé,et al.  Cardiopulmonary bypass with Nikkiso and BioMedicus centrifugal pumps. , 1994, Artificial organs.

[4]  H. Nishida,et al.  Development of the Terumo Capiox centrifugal pump and its clinical application to open heart surgery: a comparative study with the roller pump. , 2008, Artificial organs.

[5]  H. Nishida,et al.  Percutaneous cardiopulmonary support as the second generation of venoarterial bypass: current status and future direction. , 2008, Artificial organs.

[6]  Y Nosé,et al.  A fluid dynamic analysis using flow visualization of the Baylor/NASA implantable axial flow blood pump for design improvement. , 1995, Artificial organs.

[7]  Y. Ohara,et al.  Hemolytic characteristics of a pivot bearing supported Gyro centrifugal pump (C1E3) simulating various clinical applications. , 1996, Artificial organs.

[8]  Y Nosé,et al.  Hydraulic assessment of the floating impeller phenomena in a centrifugal pump. , 1997, Artificial organs.

[9]  G. Noon,et al.  Comparison of Delphin and BioMedicus pumps. , 1990, ASAIO transactions.

[10]  Y Nosé,et al.  Development and evaluation of antithrombogenic centrifugal pump: the Baylor C-Gyro Pump Eccentric Inlet Port Model. , 1994, Artificial organs.

[11]  G Damm,et al.  Baylor Gyro Pump: a completely seal-less centrifugal pump aiming for long-term circulatory support. , 2008, Artificial organs.

[12]  W. Williams,et al.  Determinants of success in pediatric cardiac patients undergoing extracorporeal membrane oxygenation. , 1995, The Annals of thoracic surgery.

[13]  Y Nosé,et al.  Development of an axial flow ventricular assist device: in vitro and in vivo evaluation. , 1995, Artificial organs.

[14]  G Damm,et al.  An ultimate, compact, seal-less centrifugal ventricular assist device: Baylor C-Gyro pump. , 1994, Artificial organs.

[15]  S Takatani,et al.  Evaluation of the Wear of the Pivot Bearing in the Gyro C1E3 Pump. , 1996, Artificial organs.

[16]  George Damm,et al.  Development of a Pivot Bearing Supported Sealless Centrifugal Pump for Ventricular Assist. , 1996, Artificial organs.

[17]  M. Oz,et al.  Miniature axial flow pump for ventricular assistance in children and small adults. , 1996, The Journal of thoracic and cardiovascular surgery.

[18]  Y Nosé,et al.  In vitro analysis of the floating mode phenomenon in the Free Impeller Gyro Pump. , 1995, Artificial organs.

[19]  J. Antaki,et al.  Long-term animal survival with an implantable axial flow pump as a left ventricular assist device. , 2008, Artificial organs.

[20]  K. Bergh,et al.  Heparin–coated circuit during cardiopulmonary bypass , 1994 .

[21]  Y Nosé,et al.  A fluid dynamic analysis of a rotary blood pump for design improvement. , 2008, Artificial organs.

[22]  G. Noon,et al.  Ex vivo evaluation of the NASA/DeBakey axial flow ventricular assist device. Results of a 2 week screening test. , 1996, ASAIO journal.