Novel actuation design of a gait trainer with shadow leg approach

Robotic gait training has developed since the end of the 20th century, yet there is much room for improvement in the design of the robots. With the conventional exoskeleton structures, donning of patients in a gait trainer usually is a cumbersome process due to the need of joint alignments and normal walking is often hindered due to obstructed arm swing. Our goal was to design a gait training robots that overcomes these limitations. We propose a novel design in which these drawbacks are reduced to a great amount. By using a parallel structure behind the patient (shadow leg) that is connected to the patient joints with rods, little alignment is needed, the area lateral to the hip is left free, and thus arm swing is not obstructed. The construction is lightweight, because the actuators are mounted on a fixed base and the transmission of power is executed with light weight rods. An end stop in the shadow leg prevents hyper extension of the patient's knee. The relationship between motor displacement and human joint rotations is nonlinear. In this paper we derive the nonlinear relationships between motors and patient joints and verify these. calculations with a measurement. The device has been built, now tests with subjects are required to assess if subjects can indeed walk normally in the robot.

[1]  Matthias D. Ziegler,et al.  Why Variability Facilitates Spinal Learning , 2010, The Journal of Neuroscience.

[2]  H. van der Kooij,et al.  Design of a series elastic- and Bowden cable-based actuation system for use as torque-actuator in exoskeleton-type training , 2005, 9th International Conference on Rehabilitation Robotics, 2005. ICORR 2005..

[3]  Piet Lammertse,et al.  HapticMaster - a generic force controlled robot for human interaction , 2003, Ind. Robot.

[4]  F. Müller,et al.  Effects of Locomotion Training With Assistance of a Robot-Driven Gait Orthosis in Hemiparetic Patients After Stroke: A Randomized Controlled Pilot Study , 2007, Stroke.

[5]  James A. Maples,et al.  Experiments in force control of robotic manipulators , 1986, Proceedings. 1986 IEEE International Conference on Robotics and Automation.

[6]  Peggy Arnell,et al.  The Biomechanics and Motor Control of Human Gait , 1988 .

[7]  V. Dietz,et al.  Treadmill training of paraplegic patients using a robotic orthosis. , 2000, Journal of rehabilitation research and development.

[8]  Jan F. Veneman,et al.  The Effects on Kinematics and Muscle Activity of Walking in a Robotic Gait Trainer During Zero-Force Control , 2008, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[9]  M. Noel,et al.  An ElectroHydraulic Actuated Ankle Foot Orthosis to Generate Force Fields and to Test Proprioceptive Reflexes During Human Walking , 2008, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[10]  Robert Riener,et al.  Generalized elasticities improve patient-cooperative control of rehabilitation robots , 2009, 2009 IEEE International Conference on Rehabilitation Robotics.

[11]  J. Hidler,et al.  Multicenter Randomized Clinical Trial Evaluating the Effectiveness of the Lokomat in Subacute Stroke , 2009, Neurorehabilitation and neural repair.

[12]  H. van der Kooij,et al.  Design and Evaluation of the LOPES Exoskeleton Robot for Interactive Gait Rehabilitation , 2007, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[13]  S. Hesse,et al.  Gait pattern of severely disabled hemiparetic subjects on a new controlled gait trainer as compared to assisted treadmill walking with partial body weight support , 1999, Clinical rehabilitation.

[14]  Neville Hogan,et al.  An analysis of contact instability in terms of passive physical equivalents , 1989, Proceedings, 1989 International Conference on Robotics and Automation.