Automatic detection of abrupt patient motion in SPECT data acquisition

Due to the long imaging times in SPECT, patient motion is inevitable and constitutes a serious problem for any reconstruction algorithm. The measured inconsistent projection data leads to reconstruction artefacts which can significantly affect the diagnostic accuracy of SPECT, if not corrected. Among the most promising attempts for addressing this cause of artefacts, is the so-called data-driven motion correction methodology. To use this approach it is necessary to automatically detect patient motion and to subdivide the acquired data in projection sets accordingly. In this note, we propose three different schemes for automatically detecting patient motion. All methods were tested on 3D academic examples with different rigid motions, motion times, and camera systems. On the whole, every method was tested with approximately 400 to 600 test cases. One of the proposed new methods does show promising results.

[1]  R. Eisner,et al.  Quantitative analysis of the tomographic thallium-201 myocardial bullseye display: critical role of correcting for patient motion. , 1988, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[2]  D. Skerrett,et al.  A hybrid 3-D reconstruction/registration algorithm for correction of head motion in emission tomography , 2000 .

[3]  Jan Modersitzki,et al.  Numerical Methods for Image Registration , 2004 .

[4]  Bernd Fischer,et al.  A New Approach for Motion Correction in SPECT Imaging , 2007, Bildverarbeitung für die Medizin.

[5]  E. Botvinick,et al.  A quantitative assessment of patient motion and its effect on myocardial perfusion SPECT images. , 1993, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[6]  Brian F. Hutton,et al.  Practical aspects of a data-driven motion correction approach for brain SPECT , 2003, IEEE Transactions on Medical Imaging.

[7]  P.H. Pretorius,et al.  Feasibility of stereo-infrared tracking to monitor patient motion during cardiac SPECT imaging , 2004, IEEE Transactions on Nuclear Science.

[8]  Michel Defrise,et al.  Detection and correction of patient motion in SPECT imaging , 1993 .

[9]  D S Berman,et al.  "Upward creep" of the heart: a frequent source of false-positive reversible defects during thallium-201 stress-redistribution SPECT. , 1989, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[10]  J. Cooper,et al.  Effect of patient motion on tomographic myocardial perfusion imaging. , 1992, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[11]  Alain Herment,et al.  Motion detection in triple scan SPECT imaging , 1998 .

[12]  Stefan Eberl,et al.  A practical 3D tomographic method for correcting patient head motion in clinical SPECT , 1998 .

[13]  J. Wheat,et al.  Incidence and characterization of patient motion in myocardial perfusion SPECT: Part 1. , 2004, Journal of nuclear medicine technology.

[14]  R. Narayanaswamy,et al.  Patient motion correction of SPECT images: dual scan approach , 1994, Proceedings of 1994 IEEE Nuclear Science Symposium - NSS'94.

[15]  D C Barber,et al.  Use of forward projection to correct patient motion during SPECT imaging. , 1998, Physics in medicine and biology.