Techniques for Measurement of Velocity in Liquid-Metal MHD Flows
暂无分享,去创建一个
Three instruments for measuring local velocities in liquid-metal MHD experiments for fusion blanket applications are being evaluated. The devices are used in room-temperature NaK experiments to measure three-dimensional flow field patterns anticipated in complex blanket geometries. Hot film anemometry, a standard technique in ordinary fluids, is being used, as well as two developmental devices. One is called the Liquid Metal Electromagnetic Velocity Instrument (LEVI), and performs essentially as a local dc electromagnetic flow meter. The third device, a Thermal Transient Anemometer (TTA) is a rugged, yet relatively simple device, which measures local velocity through the mechanism of convective heat transfer, in some ways similar to hot-film anemometry. Results are presented showing the kinds of data collected this far with each instrument. Measurements include both local velocity measurements and some preliminary frequency analyses of the fluctuating signals from both a hot-film sensor and the LEVI device.
[1] Claude B. Reed,et al. The effect of a transverse magnetic field on shear turbulence , 1978, Journal of Fluid Mechanics.
[2] K. Miyazaki,et al. Flow and heat transfer characteristics in lithium loop under transverse magnetic field , 1983 .
[3] B. F. Picologlou,et al. Experimental facility for studying MHD effects in liquid metal cooled blankets , 1985 .