Real-time computer-aided diagnosis of diminutive rectosigmoid polyps using an auto-fluorescence imaging system and novel color intensity analysis software

Abstract Objectives: An endoscopic technique that provides ≥90% negative predictive value (NPV) for differentiating neoplastic polyps is needed for the management of diminutive (≤5 mm) rectosigmoid polyps. This study aimed to assess whether a newly developed software can achieve ≥90% NPV for differentiating rectosigmoid diminutive polyps based on the green-to-red (G/R) ratio, obtained by dividing the green color tone intensity by the red color tone intensity on autofluorescence imaging (AFI). Methods: From December 2017 to May 2018, consecutive patients with known polyps who were scheduled for endoscopic treatment at our institution were prospectively recruited. All colorectal diminutive polyps were differentiated by computer-aided diagnosis using autofluorescence imaging (CAD-AFI) using a novel software-based automatic color intensity analysis; subsequent diagnosis was made by endoscopists based on trimodal imaging endoscopy (TME), which combines AFI, white-light imaging (WLI) and magnifying narrow-band imaging (M-NBI) findings. Thereafter, all polyps were removed endoscopically, and the histopathological diagnosis was evaluated. Results: Ninety-five patients with 258 diminutive rectosigmoid polyps and 171 diminutive non-rectosigmoid polyps were enrolled. Regarding diminutive rectosigmoid polyps, the NPV for differentiating neoplastic polyps was 93.4% (184/197) [95% confidence interval (CI), 89.0%–96.4%] with CAD-AFI and 94.9% (185/195) (95% CI, 90.8%–97.5%) with TME. The accuracy, sensitivity, specificity, and positive predictive value for differentiating diminutive rectosigmoid neoplastic polyps by CAD-AFI were 91.5%, 80.0%, 95.3% and 85.2%, respectively. Conclusions: Real-time CAD-AFI was effective for differentiating diminutive rectosigmoid polyps. This objective technology, which does not require extensive training or endoscopic expertise, can contribute to the effective management of diminutive rectosigmoid polyps.

[1]  K. Chayama,et al.  Computer-aided diagnosis of colorectal polyp histology by using a real-time image recognition system and narrow-band imaging magnifying colonoscopy. , 2016, Gastrointestinal endoscopy.

[2]  J. S. Kim,et al.  Differentiating small polyp histologies using real-time screening colonoscopy with Fuji Intelligent Color Enhancement. , 2011, Clinical gastroenterology and hepatology : the official clinical practice journal of the American Gastroenterological Association.

[3]  R. Schmid,et al.  Narrow-band imaging vs. high definition white light for optical diagnosis of small colorectal polyps: a randomized multicenter trial , 2016, Endoscopy.

[4]  A. Amato,et al.  Narrow-band imaging in the prediction of surveillance intervals after polypectomy in community practice , 2015, Endoscopy.

[5]  M. Desai,et al.  Real-time optical biopsy of colon polyps with narrow band imaging in community practice does not yet meet key thresholds for clinical decisions. , 2013, Gastroenterology.

[6]  H. Park,et al.  Prospective, randomized, back-to-back trial evaluating the usefulness of i-SCAN in screening colonoscopy. , 2012, Gastrointestinal endoscopy.

[7]  Nicholas Ayache,et al.  Software for automated classification of probe-based confocal laser endomicroscopy videos of colorectal polyps. , 2012, World journal of gastroenterology.

[8]  Swati G. Patel,et al.  Real-Time Characterization of Diminutive Colorectal Polyp Histology Using Narrow-Band Imaging: Implications for the Resect and Discard Strategy. , 2016, Gastroenterology.

[9]  K. Mori,et al.  Characterization of Colorectal Lesions Using a Computer-Aided Diagnostic System for Narrow-Band Imaging Endocytoscopy. , 2016, Gastroenterology.

[10]  Henry Horng-Shing Lu,et al.  Accurate Classification of Diminutive Colorectal Polyps Using Computer-Aided Analysis. , 2017, Gastroenterology.

[11]  J. Llach,et al.  Computer-aided prediction of polyp histology on white light colonoscopy using surface pattern analysis , 2018, Endoscopy.

[12]  Shoichi Saito,et al.  Computer-aided diagnosis of neoplastic colorectal lesions using ‘real-time’ numerical color analysis during autofluorescence endoscopy , 2013, European journal of gastroenterology & hepatology.

[13]  Kazuhide Yamamoto,et al.  Prospective evaluation of endoscopic criteria characteristic of sessile serrated adenomas/polyps , 2015, Journal of Gastroenterology.

[14]  Vani Konda,et al.  ASGE Technology Committee systematic review and meta-analysis assessing the ASGE PIVI thresholds for adopting real-time endoscopic assessment of the histology of diminutive colorectal polyps. , 2015, Gastrointestinal endoscopy.

[15]  Evaluation of the effectiveness of color intensity analysis using a second‐generation autofluorescence imaging system for diminutive colorectal polyp differentiation , 2014, Digestive endoscopy : official journal of the Japan Gastroenterological Endoscopy Society.

[16]  Shoichi Saito,et al.  Efficacy of a novel auto-fluorescence imaging system with computer-assisted color analysis for assessment of colorectal lesions. , 2013, World journal of gastroenterology.

[17]  Charles J. Kahi,et al.  The American Society for Gastrointestinal Endoscopy PIVI (Preservation and Incorporation of Valuable Endoscopic Innovations) on real-time endoscopic assessment of the histology of diminutive colorectal polyps. , 2011, Gastrointestinal endoscopy.

[18]  S. Kudo,et al.  Narrow‐band imaging (NBI) magnifying endoscopic classification of colorectal tumors proposed by the Japan NBI Expert Team , 2016, Digestive endoscopy : official journal of the Japan Gastroenterological Endoscopy Society.

[19]  H. Pohl,et al.  Quality of optical diagnosis of diminutive polyps and associated factors , 2016, Endoscopy.

[20]  M. Pepe The Statistical Evaluation of Medical Tests for Classification and Prediction , 2003 .

[21]  A. Zauber,et al.  Prevention of colorectal cancer by colonoscopic polypectomy. The National Polyp Study Workgroup. , 1993 .

[22]  Douglas K Rex,et al.  High yields of small and flat adenomas with high-definition colonoscopes using either white light or narrow band imaging. , 2007, Gastroenterology.

[23]  Masahiro Oda,et al.  Impact of an automated system for endocytoscopic diagnosis of small colorectal lesions: an international web-based study , 2016, Endoscopy.

[24]  A. Zauber,et al.  Colonoscopic polypectomy and long-term prevention of colorectal-cancer deaths. , 2012, The New England journal of medicine.

[25]  Nicolas Chapados,et al.  Real-time differentiation of adenomatous and hyperplastic diminutive colorectal polyps during analysis of unaltered videos of standard colonoscopy using a deep learning model , 2017, Gut.

[26]  Charles J. Kahi,et al.  High-Definition Chromocolonoscopy vs. High-Definition White Light Colonoscopy for Average-Risk Colorectal Cancer Screening , 2010, The American Journal of Gastroenterology.

[27]  W. Ajiki,et al.  Cancer incidence and incidence rates in Japan in 2006: based on data from 15 population-based cancer registries in the monitoring of cancer incidence in Japan (MCIJ) project. , 2012, Japanese journal of clinical oncology.