Fluid force predictions and experimental measurements for a magnetically levitated pediatric ventricular assist device.

The latest generation of artificial blood pumps incorporates the use of magnetic bearings to levitate the rotating component of the pump, the impeller. A magnetic suspension prevents the rotating impeller from contacting the internal surfaces of the pump and reduces regions of stagnant and high shear flow that surround fluid or mechanical bearings. Applying this third-generation technology, the Virginia Artificial Heart Institute has developed a ventricular assist device (VAD) to support infants and children. In consideration of the suspension design, the axial and radial fluid forces exerted on the rotor of the pediatric VAD were estimated using computational fluid dynamics (CFD) such that fluid perturbations would be counterbalanced. In addition, a prototype was built for experimental measurements of the axial fluid forces and estimations of the radial fluid forces during operation using a blood analog mixture. The axial fluid forces for a centered impeller position were found to range from 0.5 +/- 0.01 to 1 +/- 0.02 N in magnitude for 0.5 +/- 0.095 to 3.5 +/- 0.164 Lpm over rotational speeds of 6110 +/- 0.39 to 8030 +/- 0.57% rpm. The CFD predictions for the axial forces deviated from the experimental data by approximately 8.5% with a maximum difference of 18% at higher flow rates. Similarly for the off-centered impeller conditions, the maximum radial fluid force along the y-axis was found to be -0.57 +/- 0.17 N. The maximum cross-coupling force in the x direction was found to be larger with a maximum value of 0.74 +/- 0.22 N. This resulted in a 25-35% overestimate of the radial fluid force as compared to the CFD predictions; this overestimation will lead to a far more robust magnetic suspension design. The axial and radial forces estimated from the computational results are well within a range over which a compact magnetic suspension can compensate for flow perturbations. This study also serves as an effective and novel design methodology for blood pump developers employing magnetic suspensions. Following a final design evaluation, a magnetically suspended pediatric VAD will be constructed for extensive hydraulic and animal testing as well as additional validation of this design methodology.

[1]  D B Olsen,et al.  In vitro characterization of a magnetically suspended continuous flow ventricular assist device. , 1995, ASAIO journal.

[2]  Paul E. Allaire,et al.  Development of a prototype magnetically suspended rotor ventricular assist device , 1996 .

[3]  Paul Allaire,et al.  Using Hybrid Magnetic Bearings to Completely Suspend the Impeller of a Ventricular Assist Device. , 1996, Artificial organs.

[4]  Paul E. Allaire,et al.  Design of a Magnetic Bearing-Supported Prototype Centrifugal Artificial Heart Pump , 1996 .

[5]  D B Olsen,et al.  Prototype Continuous Flow Ventricular Assist Device Supported on Magnetic Bearings. , 1996, Artificial organs.

[6]  P. Allaire,et al.  MAGNETIC SUSPENSION CONTROLS FOR CONTINUOUS FLOW VENTRICULAR ASSIST DEVICE CFVAD III , 1997 .

[7]  G Bearnson,et al.  Performance of a continuous flow ventricular assist device: magnetic bearing design, construction, and testing. , 1998, Artificial organs.

[8]  Paul E. Allaire,et al.  Feedback control applications in artificial hearts , 1998 .

[9]  D B Olsen,et al.  Characterization of a magnetic bearing system and fluid properties for a continuous flow ventricular assist device. , 1999, Artificial organs.

[10]  P E Allaire,et al.  A magnetic bearing system for a continuous ventricular assist device. , 1999, ASAIO journal.

[11]  D B Olsen,et al.  Test controller design, implementation, and performance for a magnetic suspension continuous flow ventricular assist device. , 1999, Artificial organs.

[12]  Nelson J. Groom,et al.  Development Progress of the University of Pittsburgh Streamliner: a Mixed Flow Blood Pump with Magnetic Bearings , 2000 .

[13]  D B Olsen,et al.  Numerical analysis of blood flow in the clearance regions of a continuous flow artificial heart pump. , 2000, Artificial organs.

[14]  Houston G Wood,et al.  Computational Fluid Dynamics Modeling of Impeller Designs for the HeartQuest Left Ventricular Assist Device , 2002, ASAIO journal.

[15]  D B Olsen,et al.  Design of a Continuous Flow Centrifugal Pediatric Ventricular Assist Device , 2003, The International journal of artificial organs.

[16]  Paul E. Allaire,et al.  Computational analysis of an axial flow pediatric ventricular assist device. , 2004, Artificial organs.

[17]  Christoph Schmidt,et al.  First clinical experience with the Incor left ventricular assist device. , 2005, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[18]  Alexandrina Untaroiu,et al.  Computational Design and Experimental Testing of a Novel Axial Flow LVAD , 2005, ASAIO journal.

[19]  Wei Jiang,et al.  Computational Design and Experimental Performance Testing of an Axial-Flow Pediatric Ventricular Assist Device , 2005, ASAIO journal.