Inroads Toward Robot-Assisted Internal Fixation of Bone Fractures Using a Bendable Medical Screw and the Curved Drilling Technique

Internal fixation is a common orthopedic procedure in which a rigid screw is used to fix fragments of a fractured bone together and expedite the healing process. However, the rigidity of the screw, geometry of the fractured anatomy (e.g. femur and pelvis), and patient's age can cause an array of complications during screw placement, such as improper fracture healing due to misalignment of the bone fragments, lengthy procedure time and subsequently high radiation exposure. To address these issues, we propose a minimally invasive robot-assisted procedure comprising of a continuum robot, called ortho-snake, together with a novel bendable medical screw (BMS) for fixating the fractures. We describe the implementation of a curved drilling technique and focus on the design, manufacturing, and evaluation of a novel BMS, which can passively morph into the drilled curved tunnels with various curvatures. We evaluate the performance and efficacy of the proposed BMS using both finite element simulations as well as experiments conducted on synthetic bone samples.

[1]  Weiliang Xu,et al.  Robotic Long Bone Fracture Reduction , 2008 .

[2]  Russell H. Taylor,et al.  Integration of a Snake-like Dexterous Manipulator for Head and Neck Surgery with the da Vinci Research Kit. , 2017 .

[3]  W. L. Foley,et al.  Internal screw fixation: comparison of placement pattern and rigidity. , 1989, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[4]  G A Brown,et al.  Computed Tomography Image Guided Surgery in Complex Acetabular Fractures , 2000, Clinical orthopaedics and related research.

[5]  Ji Ma,et al.  Autonomous suturing via surgical robot: An algorithm for optimal selection of needle diameter, shape, and path , 2017, 2017 IEEE International Conference on Robotics and Automation (ICRA).

[6]  Zerui Wang,et al.  Toward Semi-autonomous Cryoablation of Kidney Tumors via Model-Independent Deformable Tissue Manipulation Technique , 2018, Annals of Biomedical Engineering.

[7]  Russell H. Taylor,et al.  A Curved-Drilling Approach in Core Decompression of the Femoral Head Osteonecrosis Using a Continuum Manipulator , 2017, IEEE Robotics and Automation Letters.

[8]  Russell H. Taylor,et al.  Control of the coupled motion of a 6 DoF robotic arm and a continuum manipulator for the treatment of pelvis osteolysis , 2014, 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[9]  R. Zdero,et al.  The effect of screw pullout rate on screw purchase in synthetic cancellous bone. , 2009, Journal of biomechanical engineering.

[10]  J. Bishop,et al.  Cancellous Screws Are Biomechanically Superior to Cortical Screws in Metaphyseal Bone. , 2016, Orthopedics.

[11]  Leo Joskowicz,et al.  Bone-mounted miniature robot for surgical procedures: Concept and clinical applications , 2003, IEEE Trans. Robotics Autom..

[12]  B. Gueorguiev,et al.  Unique stability of femoral neck fractures treated with the novel biplane double-supported screw fixation method: a biomechanical cadaver study. , 2015, Injury.

[13]  Peter Kazanzides,et al.  Design and Integration of a Telerobotic System for Minimally Invasive Surgery of the Throat , 2009, Int. J. Robotics Res..

[14]  Ryan J. Murphy,et al.  Toward robot-assisted hard osteolytic lesion treatment using a continuum manipulator , 2016, EMBC.

[15]  Peter Kazanzides,et al.  Architecture of a surgical robot , 1992, [Proceedings] 1992 IEEE International Conference on Systems, Man, and Cybernetics.

[16]  K. Garala,et al.  Radiography, anatomy and imaging in pelvic fractures , 2018, Orthopaedics and Trauma.

[17]  Russell H. Taylor,et al.  Piecewise-rigid 2D-3D registration for pose estimation of snake-like manipulator using an intraoperative x-ray projection , 2014, Medical Imaging.