Developing Artefact Removal Algorithms to Process Data from a Microwave Imaging Device for Haemorrhagic Stroke Detection

In this paper, we present an investigation of different artefact removal methods for ultra-wideband Microwave Imaging (MWI) to evaluate and quantify current methods in a real environment through measurements using an MWI device. The MWI device measures the scattered signals in a multi-bistatic fashion and employs an imaging procedure based on Huygens principle. A simple two-layered phantom mimicking human head tissue is realised, applying a cylindrically shaped inclusion to emulate brain haemorrhage. Detection has been successfully achieved using the superimposition of five transmitter triplet positions, after applying different artefact removal methods, with the inclusion positioned at 0°, 90°, 180°, and 270°. The different artifact removal methods have been proposed for comparison to improve the stroke detection process. To provide a valid comparison between these methods, image quantification metrics are presented. An “ideal/reference” image is used to compare the artefact removal methods. Moreover, the quantification of artefact removal procedures through measurements using MWI device is performed.

[1]  Lorenzo Crocco,et al.  Design and Numerical Characterization of a Low-Complexity Microwave Device for Brain Stroke Monitoring , 2018, IEEE Transactions on Antennas and Propagation.

[2]  Ian J Craddock,et al.  Microwave Radar-Based Differential Breast Cancer Imaging: Imaging in Homogeneous Breast Phantoms and Low Contrast Scenarios , 2010, IEEE Transactions on Antennas and Propagation.

[3]  Shireen D. Geimer,et al.  Electrical Characterization of Glycerin: Water Mixtures: Implications for Use as a Coupling Medium in Microwave Tomography , 2017, IEEE Transactions on Microwave Theory and Techniques.

[4]  Eero P. Simoncelli,et al.  Image quality assessment: from error visibility to structural similarity , 2004, IEEE Transactions on Image Processing.

[5]  Lorenzo Crocco,et al.  A FEASIBILITY STUDY ON MICROWAVE IMAGING FOR BRAIN STROKE MONITORING , 2012 .

[6]  N. Ghavami,et al.  Microwave Imaging for Stroke Detection: Validation on Head-mimicking Phantom , 2019, 2019 PhotonIcs & Electromagnetics Research Symposium - Spring (PIERS-Spring).

[7]  S. Semenov Microwave tomography: review of the progress towards clinical applications , 2009, Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences.

[8]  Andreas Fhager,et al.  Microwave technology for detecting traumatic intracranial bleedings: tests on phantom of subdural hematoma and numerical simulations , 2016, Medical & Biological Engineering & Computing.

[9]  David J. Edwards,et al.  Ultrawideband microwave imaging of cylindrical objects with inclusions , 2011 .

[10]  Lorenzo Sani,et al.  UWB Device for Microwave Imaging: Validation through Phantoms , 2019, 2019 13th European Conference on Antennas and Propagation (EuCAP).

[11]  Ian J Craddock,et al.  Improved Delay-and-Sum Beamforming Algorithm for Breast Cancer Detection , 2008 .

[12]  Muhammad Adnan Elahi,et al.  Artifact Removal Algorithms for Microwave Imaging of the Breast , 2013 .

[13]  Andreas Fhager,et al.  Microwave-Based Stroke Diagnosis Making Global Prehospital Thrombolytic Treatment Possible , 2014, IEEE Transactions on Biomedical Engineering.

[14]  Panagiotis Kosmas,et al.  Towards a microwave imaging prototype based on the DBIM-TwIST algorithm and a custom-made transceiver system , 2017, 2017 International Conference on Electromagnetics in Advanced Applications (ICEAA).

[15]  C Gabriel,et al.  Dielectric properties of porcine cerebrospinal tissues at microwave frequencies: in vivo, in vitro and systematic variation with age , 2007, Physics in medicine and biology.

[16]  Marek E. Bialkowski,et al.  Microwave head imaging for stroke detection , 2011 .

[17]  Gianluigi Tiberi,et al.  Detection of haemorrhagic stroke in simulation and realistic 3-D human head phantom using microwave imaging , 2020, Biomed. Signal Process. Control..

[18]  A. Abbosh,et al.  Novel Preprocessing Techniques for Accurate Microwave Imaging of Human Brain , 2013, IEEE Antennas and Wireless Propagation Letters.

[19]  M. Lindstrom,et al.  A large-scale study of the ultrawideband microwave dielectric properties of normal breast tissue obtained from reduction surgeries , 2007, Physics in medicine and biology.

[20]  G. Tiberi,et al.  Novel microwave apparatus for breast lesions detection: Preliminary clinical results , 2019, Biomed. Signal Process. Control..

[21]  A. M. Abbosh,et al.  Clutter rejection techniques for microwave head imaging , 2015, 2015 International Symposium on Antennas and Propagation (ISAP).

[22]  Panagiotis Kosmas,et al.  Microwave Medical Imaging Based on Sparsity and an Iterative Method With Adaptive Thresholding , 2015, IEEE Transactions on Medical Imaging.

[23]  Peter Enders,et al.  Huygens' Principle as Universal Model of Propagation , 2009 .

[24]  X. Li,et al.  Confocal microwave imaging for breast cancer detection: localization of tumors in three dimensions , 2002, IEEE Transactions on Biomedical Engineering.

[25]  Lorenzo Sani,et al.  UWB device for breast microwave imaging: phantom and clinical validations , 2019, Measurement.

[26]  Amin M. Abbosh,et al.  Microwave System for Head Imaging , 2014, IEEE Transactions on Instrumentation and Measurement.

[27]  Serguei Semenov,et al.  Electromagnetic Tomography for Detection, Differentiation, and Monitoring of Brain Stroke: A Virtual Data and Human Head Phantom Study. , 2017, IEEE Antennas and Propagation Magazine.