Dosimetric characteristics of the Leipzig surface applicators used in the high dose rate brachy radiotherapy.

The nucletron Leipzig applicator is designed for (HDR) 192Ir brachy radiotherapy of surface lesions. The dosimetric characteristics of this applicator were investigated using simulation method based on Monte Carlo N-particle (MCNP) code and phantom measurements. The simulation method was validated by comparing calculated dose rate distributions of nucletron microSelectron HDR 192Ir source against published data. Radiochromic films and metal-oxide-semiconductor field-effect transistor (MOSFET) detectors were used for phantom measurements. The double exposure technique, correcting the nonuniform film sensitivity, was applied in the film dosimetry. The linear fit of multiple readings with different irradiation times performed for each MOSFET detector measurement was used to obtain the dose rate of each measurement and to correct the source transit-time error. The film and MOSFET measurements have uncertainties of 3%-7% and 3%-5%, respectively. The dose rate distributions of the Leipzig applicator with 30 mm opening calculated by the validated MC method were verified by measurements of film and MOSFET detectors. Calculated two-dimensional planar dose rate distributions show similar patterns as the film measurement. MC calculated dose rate at a reference point defined at depth 5 mm on the applicator's central axis is 7% lower than the film and 3% higher than the MOSFET measurements. The dose rate of a Leipzig applicator with 30 mm opening at reference point is 0.241+/-3% cGy h(-1) U(-1). The MC calculated depth dose rates and profiles were tabulated for clinic use.

[1]  R. Jeraj,et al.  A flattening filter for brachytherapy skin irradiation. , 2002, Physics in medicine and biology.

[2]  M. Yassa,et al.  Surface applicators for high dose rate brachytherapy in AIDS-related Kaposi's sarcoma. , 1997, International journal of radiation oncology, biology, physics.

[3]  Arne Miller,et al.  Novel Radiochromic Films for Clinical Dosimetry , 1996 .

[4]  J. Williamson,et al.  Monte Carlo-aided dosimetry of a new high dose-rate brachytherapy source. , 1998, Medical physics.

[5]  R. Ramani,et al.  Clinical dosimetry using MOSFETs. , 1997, International journal of radiation oncology, biology, physics.

[6]  J. Galvin,et al.  Radiochromic film dosimetry: recommendations of AAPM Radiation Therapy Committee Task Group 55. American Association of Physicists in Medicine. , 1998, Medical physics.

[7]  L. Anderson,et al.  Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43 , 1995 .

[8]  J. F. Briesmeister MCNP-A General Monte Carlo N-Particle Transport Code , 1993 .

[9]  J F Williamson,et al.  Quantitative evaluation of radiochromic film response for two-dimensional dosimetry. , 1997, Medical physics.

[10]  Tomas Kron,et al.  Optimal flattening filter shape of a surface brachytherapy applicator. , 2002, Physics in medicine and biology.

[11]  J Cygler,et al.  Evaluation of a dual bias dual metal oxide-silicon semiconductor field effect transistor detector as radiation dosimeter. , 1994, Medical physics.

[12]  Dose perturbation induced by radiographic contrast inside brachytherapy balloon applicators. , 2004, Medical physics.

[13]  Benjamin Guix,et al.  Treatment of skin carcinomas of the face by high-dose-rate brachytherapy and custom-made surface molds , 2000 .

[14]  G. Glasgow,et al.  Specific gamma-ray constant and exposure rate constant of 192Ir. , 1979, Medical physics.