A motion artifact generation and assessment system for the rapid testing of surface biopotential electrodes.
暂无分享,去创建一个
[1] J. Webster,et al. Minimizing Electrode Motion Artifact by Skin Abrasion , 1977, IEEE Transactions on Biomedical Engineering.
[2] K. Kearney,et al. Quantification of Motion Artifact in ECG Electrode Design , 2007, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.
[3] John G. Webster,et al. Electrocardiographic motion artifact versus electrode impedance , 2005, IEEE Transactions on Biomedical Engineering.
[4] S. Leonhardt,et al. Characterization of textile electrodes and conductors using standardized measurement setups , 2010, Physiological measurement.
[5] J. Webster,et al. Dry electrodes for electrocardiography , 2013, Physiological measurement.
[6] J. Webster,et al. The origin of skin-stretch-caused motion artifacts under electrodes. , 1996, Physiological measurement.
[7] Kang-Hwi Lee,et al. Heart Monitoring Garments Using Textile Electrodes for Healthcare Applications , 2009, Journal of Medical Systems.
[8] S Odman. Potential and impedance variations following skin deformation. , 1981, Medical & biological engineering & computing.
[9] A. Gruetzmann,et al. Novel dry electrodes for ECG monitoring , 2007, Physiological measurement.
[10] Willis J. Tompkins,et al. A Real-Time QRS Detection Algorithm , 1985, IEEE Transactions on Biomedical Engineering.
[11] J P Clarys,et al. Electromyography in sports and occupational settings: an update of its limits and possibilities , 2000, Ergonomics.
[12] Sunyoung Kim,et al. Correlation Between Electrode-Tissue Impedance and Motion Artifact in Biopotential Recordings , 2012, IEEE Sensors Journal.
[13] E Marani,et al. Low Frequency Changes in Skin Surface Potentials by Skin Compression: Experimental Results and Theories , 2003, Archives of physiology and biochemistry.
[14] Wilhelm Stork,et al. Reliable motion artifact detection for ECG monitoring systems with dry electrodes , 2008, 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.
[15] Hui Zhang,et al. A dynamic measurement system for evaluating dry bio-potential surface electrodes , 2013 .
[16] Mario Lamontagne,et al. Application of Electromyography in Sport Medicine , 2001 .
[17] J. Lauter,et al. Wearable approach for continuous ECG - and activity patient-monitoring , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.
[18] Jari Hyttinen,et al. Effect of pressure and padding on motion artifact of textile electrodes , 2013, Biomedical engineering online.
[19] Steffen Leonhardt,et al. Skin Electrode Impedance of Textile Electrodes for Bioimpedance Spectroscopy , 2007 .
[20] Wilhelm Stork,et al. An approach to reliable motion artifact detection for mobile long-term ECG monitoring systems using dry electrodes , 2007 .
[21] David A. Tong,et al. Adaptive reduction of motion artifact in the electrocardiogram , 2002, Proceedings of the Second Joint 24th Annual Conference and the Annual Fall Meeting of the Biomedical Engineering Society] [Engineering in Medicine and Biology.
[22] L. Kirkup,et al. A direct comparison of wet, dry and insulating bioelectric recording electrodes. , 2000, Physiological measurement.
[23] A. Johansson,et al. Electro-mechanical stability of surface EMG sensors , 2007, Medical & Biological Engineering & Computing.
[24] Refet Firat Yazicioglu,et al. Motion artifact reduction in ambulatory ECG monitoring: an integrated system approach , 2011, Wireless Health.
[25] Maria Romano,et al. Relevance of motion artifact in electromyography recordings during vibration treatment. , 2009, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.
[26] P.S. Hamilton,et al. Comparison of methods for adaptive removal of motion artifact , 2000, Computers in Cardiology 2000. Vol.27 (Cat. 00CH37163).
[27] Tao Xiaoming,et al. Measurement of wearable electrode and skin mechanical interaction using displacement and pressure sensors , 2011, 2011 4th International Conference on Biomedical Engineering and Informatics (BMEI).
[28] S. Ödman,et al. Movement-induced potentials in surface electrodes , 1982, Medical and Biological Engineering and Computing.