A high-efficiency power and data transmission system for biomedical implanted electronic devices

In biomedical engineering, inductive transcutaneous links can be used for power and data transfer between external systems and implanted electronic devices. The development of a micro-telemeter having a significant implantation depth needs a high-efficiency magnetic transcutaneous link. This paper presents a new system, which uses a multi-frequency load network for transmitter coil based on the class E power amplifier. At the carrier frequency used, the resistive load is influenced by the coupling of the coils and by the variation of the implant equivalent resistance. Modulating this latter between two rails permits one to modulate the amplitude of the external transmitter current and then to transmit internal data without the use of the classical implanted emitter design. Furthermore, the fact that the modulation index depends on the coupling factor, allows one to find the external coil's correct position using a position feedback loop. A complete study of the concept of digital data transmission by impedance modulation associated with a class E power amplifier is presented. Internal data transmission using this system yields a decrease of the internal electronic circuitry bulk and constitutes a high-efficiency energizing device. A theoretical investigation shows that the efficiency of the power transfer varies between 44 and 75% within a wide range of implantation depths (20 - 40 mm).

[1]  B. Hansen,et al.  An implantable, externally powered radiotelemetric system for long-term ECG and heart-rate monitoring. , 1982, Biotelemetry and patient monitoring.

[2]  Bruce C. Towe,et al.  Passive Biotelemetry by Frequency Keying , 1986, IEEE Transactions on Biomedical Engineering.

[3]  Donaldson Nd Passive signalling via inductive coupling. , 1986 .

[4]  R. White,et al.  A Wide-Band Efficient Inductive Transdennal Power and Data Link with Coupling Insensitive Gain , 1987, IEEE Transactions on Biomedical Engineering.

[5]  Marian K. Kazimierczuk,et al.  Exact analysis of class E tuned power amplifier at any Q and switch duty cycle , 1987 .

[6]  Erwin S. Hochmair,et al.  System Optimization for Improved Accuracy in Transcutaneous Signal and Power Transmission , 1984, IEEE Transactions on Biomedical Engineering.

[7]  P.R. Troyk,et al.  Closed-loop class E transcutaneous power and data link for MicroImplants , 1992, IEEE Transactions on Biomedical Engineering.

[8]  P.J. Dimbylow Finite-difference time-domain calculations of absorbed power in the ankle for 10-100 MHz plane wave exposure , 1991, IEEE Transactions on Biomedical Engineering.

[9]  Mani Soma,et al.  Radio-Frequency Coils in Implantable Devices: Misalignment Analysis and Design Procedure , 1987, IEEE Transactions on Biomedical Engineering.

[10]  W.J. Heetderks,et al.  RF powering of millimeter- and submillimeter-sized neural prosthetic implants , 1988, IEEE Transactions on Biomedical Engineering.

[11]  Frederick H. Raab,et al.  Effects of circuit variations on the class E tuned power amplifier , 1978 .

[12]  F. C. Flack,et al.  Mutual inductance of air-cored coils: Effect on design of radio-frequency coupled implants , 1971, Medical and biological engineering.

[13]  M. Sawan,et al.  Computerized transcutaneous control of a multichannel implantable urinary prosthesis , 1992, IEEE Transactions on Biomedical Engineering.

[14]  M. Kazimierczuk Collector amplitude modulation of the class E tuned power amplifier , 1984 .

[15]  No Sokal,et al.  CLASS-E - NEW CLASS OF HIGH-EFFICIENCY TUNED SINGLE-ENDED SWITCHING POWER AMPLIFIERS , 1975 .

[16]  C.M. Zierhofer,et al.  High-efficiency coupling-insensitive transcutaneous power and data transmission via an inductive link , 1990, IEEE Transactions on Biomedical Engineering.

[17]  Maria A. Stuchly,et al.  Energy Deposition in a Model of Man: Frequency Effects , 1986, IEEE Transactions on Biomedical Engineering.

[18]  Zoubir Hamici,et al.  A preliminary study of an implanted device powered by an inductive link for the telemetry of the epicardic electrocardiogram and the radionuclide activity of the left ventricle , 1995 .