Thermal Treatment of Eight CVOC Source Zones to Near Nondetect Concentrations

In situ thermal desorption (ISTD) was used for the treatment of eight separate source zones containing chlorinated solvents in a tight loess (silt/clay) above the water table. The source areas were as much as 365 m (1200 feet) apart. A target volume of 38,200 m 3 (49,950 cubic yards) of subsurface material to a depth of 9.1 m (30 feet) was treated in a period of 177 days. Energy was delivered through 367 thermal conduction heater borings, and vapors were extracted from 68 vertical vacuum wells. A vapor extraction and capture system, including a surface cover and vertical vacuum wells next to heater borings, provided for effective pneumatic control and capture of the chlorinated volatile organic compound (CVOC) vapors. A central treatment system, based on condensation and granular activated carbon filtration, was used to treat the vapors. Approximately 5675 kg (12,500 pounds) of contaminants was recovered in the extracted vapors. Forty-seven soil samples were used to document remedial performance. Based on these, the concentrations of the target contaminants were reduced to below the target remedial goals in all eight areas, typically with concentrations below 0.01 mg/kg in locations that had had CVOC concentrations higher than 1000 mg/kg. Turn-key costs for the thermal remediation were $3.9 million, and the unit treatment cost, including all utilities, was $103 per cubic meter treated ($79 per cubic yard).

[1]  HEAT AND MASS TRANSFER IN CLEAN-UP OF UNDERGROUND TOXIC WASTES , 1996 .

[2]  R. Baker,et al.  Use of Thermal Conduction Heating for the Remediation of DNAPL in Fractured Bedrock , 2008 .

[3]  John A. Cherry,et al.  Dense Chlorinated Solvents and other DNAPLs in Groundwater , 1996 .

[4]  G. Heron,et al.  Henry's Law Constant for Trichloroethylene between 10 and 95 °C , 1998 .

[5]  G. Heron,et al.  Soil heating for enhanced remediation of chlorinated solvents : A laboratory study on resistive heating and vapor extraction in a silty, low-permeable soil contaminated with trichloroethylene , 1998 .

[6]  N. L. Wolfe,et al.  Homogeneous hydrolysis rate constants for selected chlorinated methanes, ethanes, ethenes, and propanes , 1989 .

[7]  K. Udell,et al.  Heat transfer in porous media heated from above with evaporation, condensation, and capillary effects , 1983 .

[8]  Kent S. Udell,et al.  Steam distillation of a single component hydrocarbon liquid in porous media , 1993 .

[9]  B. Sleep,et al.  Thermal variation of organic fluid properties and impact on thermal remediation feasibility , 1997 .

[10]  G. Heron,et al.  Full‐Scale Removal of DNAPL Constituents Using Steam‐Enhanced Extraction and Electrical Resistance Heating , 2005 .

[11]  Kent S. Udell,et al.  Nonaqueous phase liquid transport and cleanup: 1. Analysis of mechanisms , 1988 .

[12]  Cass T. Miller,et al.  Evaluation of Thermal Effects on the Dissolution of a Nonaqueous Phase Liquid in Porous Media , 1997 .

[13]  James W. Mercer,et al.  A review of immiscible fluids in the subsurface: properties, models, characterization and remediation , 1990 .