The presence of moisture in building materials causes damage second only to structural one. NDT are successfully applied to map moisture distribution, to localize the source of water and to determine microclimatic conditions. IR Thermography has the advantage of non-destructive testing while it allows to investigate large surfaces. The measures can be repeated in time to monitor the phenomenon of raising water. Nevertheless the investigation of moisture in walls is one of the less reliable application of Thermography IR applied to cultural heritage preservation. The temperature of the damp areas can be colder than dry ones, because of surface evaporation, or can be warmer, because of the higher thermal inertia of water content versus building materials. The apparent discrepancies between the two results are due to the different microclimatic conditions of the scanning. Aim of the paper is to describe optimal procedures to obtain reliable maps of moisture in building materials, at different environmental and microclimatic conditions. Another goal is the description of the related energetic phenomena, which cause temperature discontinuities, and that are detected by thermography. Active and passive procedures are presented and compared. Case studies show some examples of procedures application.
[1] Ermanno G. Grinzato,et al. Moisture evaluation by dynamic thermography data modeling , 1994, Defense, Security, and Sensing.
[2] Jack R. White. Infrared and its applications , 1984 .
[3] Antonio Colantonio. Thermal Performance Patterns on Solid Masonry Exterior Walls of Historic Buildings , 1997 .