Comparative Study of AC and Positive and Negative DC Visual Corona for Sphere-Plane Gaps in Atmospheric Air

Due to the expansion of high-voltage direct current (HVDC) power systems, manufacturers of high-voltage (HV) hardware for alternating current (ac) applications are focusing their efforts towards the HVDC market. Because of the historical preponderance of ac power systems, such manufacturers have a strong background in ac corona but they need to acquire more knowledge about direct current (dc) corona. Due to the complex nature of corona, experimental data is required to describe its behavior. This work performs an experimental comparative analysis between the inception of ac corona and positive and negative dc corona. First, the sphere-plane air gap is analyzed from experimental data, and the corona inception voltages for different geometries are measured in a high-voltage laboratory. Next, the surface electric field strength is determined from finite element method simulations, since it provides valuable information about corona inception conditions. The experimental data obtained are fitted to an equation based on Peek’slaw,whichallows determining the equivalence between the visual corona surface electric field strength for ac and dc supply. Finally, additional experimental results performed on substation connectors are presented to further validate the previous results by means of commercial high-voltage hardware. The results presented in this paper could be especially valuable for high-voltage hardware manufacturers, since they allow determining the dc voltage and electric field values at which their ac products can withstand free of corona when operating in dc grids.

[1]  Toomas Plank,et al.  Positive Corona at Combined DC and AC Voltage , 2010 .

[2]  Xiang Cui,et al.  Influence of AC voltage on the positive DC corona current pulses in a wire-cylinder gap , 2016 .

[3]  Gilsoo Jang,et al.  HVDC-System-Interaction Assessment through Line-Flow Change-Distribution Factor and Transient-Stability Analysis at Planning Stage , 2016 .

[4]  Zhibin Qiu,et al.  Prediction Study on Positive DC Corona Onset Voltage of Rod-plane Air Gaps and Its Application to the Design of Valve Hall Fittings , 2016 .

[5]  P. Mikropoulos,et al.  Threshold inception conditions for positive DC corona in the coaxial cylindrical electrode arrangement under variable atmospheric conditions , 2015, IEEE Transactions on Dielectrics and Electrical Insulation.

[6]  Yu Zhang,et al.  Trichel pulse in various gases and the key factor for its formation , 2017, Scientific Reports.

[7]  Chuyan Zhang,et al.  Positive dc corona inception on dielectric-coated stranded conductors in air , 2016 .

[8]  Ronald Waters,et al.  Direct measurement of electric field at line conductors during a.c. corona , 1972 .

[9]  Matilde Sánchez Fernández,et al.  Antenna Deployment for the Localization of Partial Discharges in Open-Air Substations , 2016, Sensors.

[10]  J. M. K. MacAlpine,et al.  Comparison of methods for determining corona inception voltages of transmission line conductors , 2013 .

[11]  Xiang Cui,et al.  Analysis of Corona Onset Electric Field Considering the Effect of Space Charges , 2011, IEEE Transactions on Magnetics.

[12]  F. W. Peek The Law of Corona and the Dielectric Strength of Air-II , 1912, Transactions of the American Institute of Electrical Engineers.

[13]  Deming Yu,et al.  Corona-generated space charge effects on electric field distribution for an indoor corona cage and a monopolar test line , 2011, IEEE Transactions on Dielectrics and Electrical Insulation.

[14]  Ming Dong,et al.  Joint Visualization Diagnosis of Outdoor Insulation Status With Optical and Acoustical Detections , 2019, IEEE Transactions on Power Delivery.

[15]  P. N. Mikropoulos,et al.  Negative DC corona inception in coaxial cylinders under variable atmospheric conditions: A comparison with positive corona , 2016, IEEE Transactions on Dielectrics and Electrical Insulation.

[16]  Zhong-Xin Li,et al.  Numerical calculation of the corona onset voltage for bundle conductors for HVDC transmission line , 2011 .

[17]  N.M. Ijumba,et al.  Comparative studies of DC corona losses in a corona cage and a point-plane gap , 2007, AFRICON 2007.

[18]  M.M. El-Bahy Onset voltage of negative corona in point-cup gaps , 2002, Annual Report Conference on Electrical Insulation and Dielectric Phenomena.

[19]  D.V.Razevig High voltage engineering , 2006, 2006 Eleventh International Middle East Power Systems Conference.

[20]  Qiang Yao,et al.  Development processes of positive and negative DC corona under needle-plate electrode in air , 2016, 2016 IEEE International Conference on High Voltage Engineering and Application (ICHVE).

[21]  SUNDAY FUND,et al.  The Distribution Committee , 1914, The Hospital.

[22]  Thanapong Suwanasri,et al.  Experimental Investigation of the Corona Discharge in Electrical Transmission due to AC/DC Electric Fields , 2016 .

[23]  Yu Zhang,et al.  Characteristics of ionic wind in needle-to-ring corona discharge , 2015 .

[24]  U. Fromm,et al.  Partial discharge and Breakdown Testing at High DC Voltage , 1995 .

[25]  Mazen Abdel-Salam,et al.  Electric fields and corona currents in needle-to-meshed plate gaps , 2007 .

[26]  S. Pekárek Effect of polarity on ozone production of DC corona discharge with and without photocatalyst , 2009 .

[27]  Jane H. Davidson,et al.  Ozone Production in the Negative DC Corona: The Dependence of Discharge Polarity , 2003 .

[28]  Sabah I. Wais,et al.  Sphere-to-Plane Electrodes Configuration of Positive and Negative Plasma Corona Discharge , 2013 .

[29]  Leandros A. Maglaras,et al.  THE POLARITY EFFECT AND THE CORONA CURRENT IN SMALL AIR GAPS , 2012 .

[30]  P. Casals-Torrens,et al.  Determination of the corona inception voltage in an extra high voltage substation connector , 2013, IEEE Transactions on Dielectrics and Electrical Insulation.

[31]  Jen-Shih Chang,et al.  Corona discharge processes , 1991 .

[32]  Jordi-Roger Riba,et al.  Simplification and cost reduction of visual corona tests , 2018 .

[33]  A. Pedersen,et al.  Analysis of Spark Breakdown Characteristics for Sphere Gaps , 1967 .

[34]  Ute Ebert,et al.  Positive and negative streamers in ambient air: measuring diameter, velocity and dissipated energy , 2008, 0805.1376.

[35]  Pavel Trnka,et al.  Pulse sequence analysis of corona discharge at DC voltage , 2016, 2016 Diagnostic of Electrical Machines and Insulating Systems in Electrical Engineering (DEMISEE).

[36]  R. S. Sigmond,et al.  Corona and Insulation , 1981, IEEE Transactions on Electrical Insulation.

[37]  Ivan J. S. Lopes,et al.  Experimental investigation of corona onset in contaminated polymer surfaces , 2015, IEEE Transactions on Dielectrics and Electrical Insulation.

[38]  J. Davidson,et al.  Model of the Negative DC Corona Plasma: Comparison to the Positive DC Corona Plasma , 2003 .