Chest compression rate feedback based on transthoracic impedance.

BACKGROUND Quality of cardiopulmonary resuscitation (CPR) is an important determinant of survival from cardiac arrest. The use of feedback devices is encouraged by current resuscitation guidelines as it helps rescuers to improve quality of CPR performance. AIM To determine the feasibility of a generic algorithm for feedback related to chest compression (CC) rate using the transthoracic impedance (TTI) signal recorded through the defibrillation pads. METHODS We analysed 180 episodes collected equally from three different emergency services, each one using a unique defibrillator model. The new algorithm computed the CC-rate every 2s by analysing the TTI signal in the frequency domain. The obtained CC-rate values were compared with the gold standard, computed using the compression force or the ECG and TTI signals when the force was not recorded. The accuracy of the CC-rate, the proportion of alarms of inadequate CC-rate, chest compression fraction (CCF) and the mean CC-rate per episode were calculated. RESULTS Intervals with CCs were detected with a mean sensitivity and a mean positive predictive value per episode of 96.3% and 97.0%, respectively. Estimated CC-rate had an error below 10% in 95.8% of the time. Mean percentage of accurate alarms per episode was 98.2%. No statistical differences were found between the gold standard and the estimated values for any of the computed metrics. CONCLUSION We developed an accurate algorithm to calculate and provide feedback on CC-rate using the TTI signal. This could be integrated into automated external defibrillators and help improve the quality of CPR in basic-life-support settings.

[1]  Henry E. Wang,et al.  Comparison of methods for the determination of cardiopulmonary resuscitation chest compression fraction. , 2012, Resuscitation.

[2]  Sofía Ruiz de Gauna,et al.  Reliability and accuracy of the thoracic impedance signal for measuring cardiopulmonary resuscitation quality metrics. , 2015, Resuscitation.

[3]  R. Koster,et al.  Accurate feedback of chest compression depth on a manikin on a soft surface with correction for total body displacement. , 2014, Resuscitation.

[4]  E. Aramendi,et al.  Automatic detection of chest compressions for the assessment of CPR-quality parameters. , 2014, Resuscitation.

[5]  H. Halperin,et al.  Determination of the noise source in the electrocardiogram during cardiopulmonary resuscitation , 2002, Critical care medicine.

[6]  M. Daya,et al.  Can thoracic impedance monitor the depth of chest compressions during out-of-hospital cardiopulmonary resuscitation? , 2014, Resuscitation.

[7]  Trygve Eftestøl,et al.  Impedance-Based Ventilation Detection During Cardiopulmonary Resuscitation , 2007, IEEE Transactions on Biomedical Engineering.

[8]  Rolf Rossaint,et al.  New visual feedback device improves performance of chest compressions by professionals in simulated cardiac arrest. , 2010, Resuscitation.

[9]  Jo Kramer-Johansen,et al.  Quality of cardiopulmonary resuscitation during out-of-hospital cardiac arrest , 2005 .

[10]  Richard A. Field,et al.  The impact of chest compression rates on quality of chest compressions - a manikin study. , 2012, Resuscitation.

[11]  M. Lloyd Chest Compression Rates and Survival Following Out-of-Hospital Cardiac Arrest , 2015 .

[12]  Maaret Castrén,et al.  European Resuscitation Council Guidelines for Resuscitation 2010 Section 2. Adult basic life support and use of automated external defibrillators , 2010, Resuscitation.

[13]  Helge Myklebust,et al.  CPR quality improvement during in-hospital cardiac arrest using a real-time audiovisual feedback system. , 2007, Resuscitation.

[14]  Gavin D Perkins,et al.  European Resuscitation Council Guidelines for Resuscitation 2010 Section 4. Adult advanced life support. , 2010, Resuscitation.

[15]  D. Davis,et al.  Relationship Between Chest Compression Rates and Outcomes From Cardiac Arrest , 2012, Circulation.

[16]  C. Callaway,et al.  Effect of real-time feedback during cardiopulmonary resuscitation outside hospital: prospective, cluster-randomised trial , 2011, BMJ : British Medical Journal.

[17]  Adam Almozlino,et al.  Cardiopulmonary resuscitation feedback improves the quality of chest compression provided by hospital health care professionals. , 2011, The American journal of emergency medicine.

[18]  L. Wik,et al.  Transthoracic impedance used to evaluate performance of cardiopulmonary resuscitation during out of hospital cardiac arrest. , 2008, Resuscitation.

[19]  B. Abella,et al.  Uniform reporting of measured quality of cardiopulmonary resuscitation (CPR). , 2007, Resuscitation.

[20]  K. Monsieurs,et al.  Excessive chest compression rate is associated with insufficient compression depth in prehospital cardiac arrest. , 2012, Resuscitation.

[21]  B. Abella,et al.  Quality of cardiopulmonary resuscitation during in-hospital cardiac arrest. , 2005, JAMA.

[22]  Cpr , 2005, Key Topics In Anaesthesia.

[23]  Jo Kramer-Johansen,et al.  Quality of out-of-hospital cardiopulmonary resuscitation with real time automated feedback: a prospective interventional study. , 2006, Resuscitation.

[24]  B. Abella,et al.  Chest Compression Rates During Cardiopulmonary Resuscitation Are Suboptimal: A Prospective Study During In-Hospital Cardiac Arrest , 2005, Circulation.

[25]  Trygve Eftestøl,et al.  Thoracic impedance changes measured via defibrillator pads can monitor ventilation in critically ill patients and during cardiopulmonary resuscitation* , 2006, Critical care medicine.

[26]  A. Handley,et al.  [European Resuscitation Council Guidelines 2000 for adult basic life support]. , 2001, Medicina clinica.

[27]  Benjamin S. Abella,et al.  Cardiopulmonary Resuscitation Quality: Improving Cardiac Resuscitation Outcomes Both Inside and Outside the Hospital A Consensus Statement From the American Heart Association , 2013, Circulation.