A functional methodology on the manufacturing of customized polymeric cranial prostheses from CAT using SPIF

Purpose This paper aims to propose a functional methodology to produce cranial prostheses in polymeric sheet. Within the scope of rapid prototyping technologies, the single-point incremental forming (SPIF) process is used to demonstrate its capabilities to perform customized medical parts. Design/methodology/approach The methodology starts processing a patient’s computerized axial tomography (CAT) and follows with a computer-aided design and manufacture (CAD/CAM) procedure, which finally permits the successful manufacturing of a customized prosthesis for a specific cranial area. Findings The formability of a series of polymeric sheets is determined and the most restrictive material among them is selected for the fabrication of a specific partial cranial prosthesis following the required geometry. The final strain state at the outer surface of the prosthesis is analysed, showing the high potential of SPIF in manufacturing individualized cranial prostheses from polymeric sheet. Originality/value This paper proposes a complete methodology to design and manufacture polymer customized cranial prostheses from patients’ CATs using the novel SPIF technology. This is an application of a new class of materials to the manufacturing of medical prostheses by SPIF, which to this purpose has been mainly making use of metallic materials so far. Despite the use of polymers to this application is still to be validated from a medical point of view, transparent prostheses can already be of great interest in medical or engineering schools for teaching and research purposes.

[1]  A. H. van den Boogaard,et al.  An overview of stabilizing deformation mechanisms in incremental sheet forming , 2009 .

[2]  L. Mercuri,et al.  Twenty-year follow-up study on a patient-fitted temporomandibular joint prosthesis: the Techmedica/TMJ Concepts device. , 2015, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[3]  L. González-Pérez,et al.  Two-year prospective study of outcomes following total temporomandibular joint replacement. , 2016, International journal of oral and maxillofacial surgery.

[4]  Paulo A.F. Martins,et al.  Single point incremental forming of PVC , 2009 .

[5]  A. Atkins Fracture in forming , 1996 .

[6]  U. Tekin,et al.  Biomechanical evaluation of a new design titanium miniplate for the treatment of mandibular angle fractures. , 2014, International journal of oral and maxillofacial surgery.

[7]  Joaquim Ciurana,et al.  Rapid tooling using 3D printing system for manufacturing of customized tracheal stent , 2014 .

[8]  Joost Duflou,et al.  Asymmetric single point incremental forming of sheet metal , 2005 .

[9]  Jüri Majak,et al.  Modelling and optimal design of sheet metal RP&M processes , 2005 .

[10]  R. Bentley,et al.  Custom-made titanium cranioplasty: early and late complications of 151 cranioplasties and review of the literature. , 2015, International journal of oral and maxillofacial surgery.

[11]  Paulo A.F. Martins,et al.  Hole-flanging by incremental sheet forming , 2012 .

[12]  G. Centeno,et al.  Critical analysis of necking and fracture limit strains and forming forces in single-point incremental forming , 2014 .

[13]  Paulo A.F. Martins,et al.  On the potential of single point incremental forming of sheet polymer parts , 2012 .

[14]  Niels Bay,et al.  Failure mechanisms in single-point incremental forming of metals , 2011 .

[15]  Maria Luisa Garcia-Romeu,et al.  Manufacturing of Polymeric Biocompatible Cranial Geometry by Single Point Incremental Forming , 2015 .

[16]  Sankar Karmakar,et al.  Additive manufacturing in prosthesis development – a case study , 2014 .

[17]  Maria Luisa Garcia-Romeu,et al.  Incremental forming of polymers: Process parameters selection from the perspective of electric energy consumption and cost , 2016 .

[18]  Petru Berce,et al.  Customized implants with specific properties, made by selective laser melting , 2015 .

[19]  Li Gang,et al.  Fabrication of customised maxillo‐facial prosthesis using computer‐aided design and rapid prototyping techniques , 2006 .

[20]  Joaquim Ciurana,et al.  Forming force and temperature effects on single point incremental forming of polyvinylchloride , 2015 .

[21]  A Terrier,et al.  Measurements of three-dimensional glenoid erosion when planning the prosthetic replacement of osteoarthritic shoulders. , 2014, The bone & joint journal.

[22]  S. Gopakumar RP in medicine: a case study in cranial reconstructive surgery , 2004 .

[23]  Bert Lauwers,et al.  Study on the achievable accuracy in single point incremental forming , 2007 .

[24]  Peter Hartley,et al.  An assessment of various process strategies for improving precision in single point incremental forming , 2011 .

[25]  Ana Reis,et al.  Single point incremental forming of a facial implant , 2014, Prosthetics and orthotics international.

[26]  Bert Lauwers,et al.  Medical application of single point incremental forming: cranial plate manufacturing , 2005 .

[27]  Clare Dixon,et al.  An intelligent process model: predicting springback in single point incremental forming , 2015 .