Scatter correction in SPECT using non-uniform attenuation data.

Quantitative assessment of activity levels with SPECT is difficult because of attenuation and scattering of gamma rays within the object. To study the effect of attenuation and scatter on SPECT quantitation, phantom studies were performed with non-uniform attenuation. Simulated transmission CT data provided information about the distribution of attenuation coefficients within the source. Attenuation correction was performed by an iterative reprojection technique. Scatter correction was done by convolution of the attenuation-corrected image and an appropriate filter. The filter characteristics depended on the attenuation and activity measurement at each pixel. The scatter correction could compensate completely for the 28% scatter component from a line source, and the 61% component from a thick, extended source. Accuracy of regional activity ratios and the linearity of the relationship between true radioactivity and the SPECT measurement were both significantly improved by these corrections. The present method is expected to be valuable for the quantitative assessment of regional activity.

[1]  K Torizuka,et al.  Determination of the pleural edge by gamma-ray transmission computed tomography. , 1981, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[2]  Y. Censor,et al.  A New Approach to the Emission Computerized Tomography Problem: Simultaneous Calculation of Attenuation and Activity Coefficients , 1979, IEEE Transactions on Nuclear Science.

[3]  Stephen D. Egbert,et al.  An Integral-Transport Method for Compton-Scatter Correction in Emission Computed Tomography , 1980, IEEE Transactions on Nuclear Science.

[4]  P. Msaki,et al.  Subtraction of Compton-scattered photons in single-photon emission computerized tomography. , 1984, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[5]  W Simon,et al.  Attenuation Correction in Gamma Emission Computed Tomography , 1981, Journal of computer assisted tomography.

[6]  R. Brooks A Quantitative Theory of the Hounsfield Unit and Its Application to Dual Energy Scanning , 1977, Journal of computer assisted tomography.

[7]  D. Bailey,et al.  Improved SPECT using simultaneous emission and transmission tomography. , 1987, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[8]  R. Jaszczak,et al.  Improved SPECT quantification using compensation for scattered photons. , 1984, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[9]  K F Koral,et al.  Performance evaluation of SPRINT, a single photon ring tomography for brain imaging. , 1984, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[10]  C E Floyd,et al.  Deconvolution of Compton scatter in SPECT. , 1985, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[11]  Lee-Tzuu Chang,et al.  A Method for Attenuation Correction in Radionuclide Computed Tomography , 1978, IEEE Transactions on Nuclear Science.

[12]  E. Hoffman,et al.  Quantitation in Positron Emission Computed Tomography: 1. Effect of Object Size , 1979, Journal of computer assisted tomography.

[13]  Ronald J. Jaszczak,et al.  Analysis of SPECT including Scatter and Attenuation Using Sophisticated Monte Carlo Modeling Methods , 1982, IEEE Transactions on Nuclear Science.