Phase contrast image segmentation using a Laue analyser crystal

Dual-energy x-ray imaging is a powerful tool enabling two-component samples to be separated into their constituent objects from two-dimensional images. Phase contrast x-ray imaging can render the boundaries between media of differing refractive indices visible, despite them having similar attenuation properties; this is important for imaging biological soft tissues. We have used a Laue analyser crystal and a monochromatic x-ray source to combine the benefits of both techniques. The Laue analyser creates two distinct phase contrast images that can be simultaneously acquired on a high-resolution detector. These images can be combined to separate the effects of x-ray phase, absorption and scattering and, using the known complex refractive indices of the sample, to quantitatively segment its component materials. We have successfully validated this phase contrast image segmentation (PCIS) using a two-component phantom, containing an iodinated contrast agent, and have also separated the lungs and ribcage in images of a mouse thorax. Simultaneous image acquisition has enabled us to perform functional segmentation of the mouse thorax throughout the respiratory cycle during mechanical ventilation.

[1]  C. Webber Photon absorptiometry, bone densitometry and the challenge of osteoporosis , 2006, Physics in medicine and biology.

[2]  K. Nugent Coherent methods in the X-ray sciences , 2009, 0908.3064.

[3]  N. Galatsanos,et al.  Multiple-image radiography. , 2003, Physics in medicine and biology.

[4]  Jean Serra Advances in Mathematical Morphology: Segmentation , 2008 .

[5]  O. Duliu,et al.  Dual-energy X-ray computer axial tomography and digital radiography investigation of cores and other objects of geological interest , 2009 .

[6]  S. Wilkins,et al.  Phase-contrast imaging of weakly absorbing materials using hard X-rays , 1995, Nature.

[7]  G Tromba,et al.  Analyser-based phase contrast image reconstruction using geometrical optics. , 2007, Physics in medicine and biology.

[8]  Zhong Zhong,et al.  Design and implementation of a compact low-dose diffraction enhanced medical imaging system. , 2009, Academic radiology.

[9]  S Jureczek,et al.  Phase contrast X-ray imaging of mice and rabbit lungs: a comparative study. , 2005, The British journal of radiology.

[10]  Anders Brahme,et al.  Development of phase-contrast X-ray imaging techniques and potential medical applications. , 2008, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[11]  Paola Coan,et al.  A method to extract quantitative information in analyzer-based x-ray phase contrast imaging , 2003 .

[12]  O. Bunk,et al.  Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sources , 2006 .

[13]  M. Kitchen,et al.  A high precision recipe for correcting images distorted by a tapered fiber optic , 2010 .

[14]  Stefan Fiedler,et al.  Synchrotron-based intra-venous K-edge digital subtraction angiography in a pig model: a feasibility study. , 2010, European journal of radiology.

[15]  Luigi Rigon,et al.  A new DEI algorithm capable of investigating sub-pixel structures , 2003 .

[16]  T E Gureyev,et al.  Quantitative analysis of two-component samples using in-line hard X-ray images. , 2002, Journal of synchrotron radiation.

[17]  R. Bracewell The Fourier Transform and Its Applications , 1966 .

[18]  C. Q. Tran Multiwavelength elemental contrast phase imaging by the use of dispersion effects , 2008 .

[19]  Ronald N. Bracewell,et al.  The Fourier Transform and Its Applications , 1966 .

[20]  David M. Paganin,et al.  Coherent X-Ray Optics , 2006 .

[21]  Xun Wang,et al.  A comparative study of deformable contour methods on medical image segmentation , 2008, Image Vis. Comput..

[22]  Boudewijn P. F. Lelieveldt,et al.  Atlas-based whole-body segmentation of mice from low-contrast Micro-CT data , 2010, Medical Image Anal..

[23]  A G Peele,et al.  Phase imaging using a polychromatic x-ray laboratory source. , 2008, Optics express.

[24]  Peter Vock,et al.  Dual energy subtraction: principles and clinical applications. , 2009, European journal of radiology.

[25]  V. N. Ingal,et al.  X-ray plane-wave topography observation of the phase contrast from a non-crystalline object , 1995 .

[26]  E Castelli,et al.  The mammography project at the SYRMEP beamline. , 2008, European journal of radiology.

[27]  H. Rubin,et al.  The approximation of symmetric X-ray peaks by Pearson type VII distributions , 1977 .

[28]  Timur E. Gureyev,et al.  Refracting Röntgen’s rays: Propagation-based x-ray phase contrast for biomedical imaging , 2009 .

[29]  Kentaro Uesugi,et al.  X-ray phase, absorption and scatter retrieval using two or more phase contrast images. , 2010, Optics express.

[30]  Fabian Bamberg,et al.  Characterization of Osteoarthritic and Normal Human Patella Cartilage by Computed Tomography X-ray Phase-Contrast Imaging: A Feasibility Study , 2010, Investigative radiology.

[31]  Kentaro Uesugi,et al.  Simultaneous acquisition of dual analyser-based phase contrast X-ray images for small animal imaging. , 2008, European journal of radiology.

[32]  Alberto Bravin,et al.  Phase-contrast X-ray imaging of breast , 2010, Acta radiologica.

[33]  Introduction to the Science of Medical Imaging: Contrast agents for x-ray and MR imaging , 2009 .

[34]  E. Pisano,et al.  Diffraction enhanced x-ray imaging. , 1997, Physics in medicine and biology.

[35]  T. Gureyev,et al.  Phase retrieval using coherent imaging systems with linear transfer functions , 2004 .

[36]  P. Cloetens,et al.  Phase objects in synchrotron radiation hard x-ray imaging , 1996 .

[37]  Bernd Jähne,et al.  Practical handbook on image processing for scientific and technical applications , 2004 .

[38]  B. Reime,et al.  Comparison of intravenous coronary angiography using synchrotron radiation with selective coronary angiography. , 2003, Journal of synchrotron radiation.

[39]  B. Simon,et al.  Regional ventilation and lung mechanics using X-Ray CT. , 2005, Academic radiology.

[40]  T. Gureyev,et al.  The binary dissector: phase contrast tomography of two- and three-material objects from few projections. , 2008, Optics express.

[41]  D. Vine,et al.  Analyzer-based phase contrast imaging and phase retrieval using a rotating anode x-ray source , 2007 .

[42]  Anatoly Snigirev,et al.  Phase-contrast X-ray imaging with synchrotron radiation for materials science applications , 2003 .

[43]  Alberto Bravin,et al.  Comparison of synchrotron radiation angiography with conventional angiography for the diagnosis of in-stent restenosis after percutaneous transluminal coronary angioplasty. , 2005, European heart journal.

[44]  S. Nicolaou,et al.  Dual energy computed tomography in tophaceous gout , 2008, Annals of the rheumatic diseases.

[45]  A Bravin,et al.  High-resolution brain tumor visualization using three-dimensional x-ray phase contrast tomography , 2007, Physics in medicine and biology.

[46]  S. Hooper,et al.  A new design for high stability pressure-controlled ventilation for small animal lung imaging , 2010 .

[47]  S. I. Fedotov,et al.  Measurements of the parameters of shell targets for laser thermonuclear fusion using an x-ray schlieren method , 1979 .

[48]  K K W Siu,et al.  Dynamic measures of regional lung air volume using phase contrast x-ray imaging , 2008, Physics in medicine and biology.

[49]  Heikki Suhonen,et al.  Paradoxical conducting airway responses and heterogeneous regional ventilation after histamine inhalation in rabbit studied by synchrotron radiation CT. , 2009, Journal of applied physiology.

[50]  Z. Hantos,et al.  Methacholine and ovalbumin challenges assessed by forced oscillations and synchrotron lung imaging. , 2009, American journal of respiratory and critical care medicine.

[51]  P. Suortti,et al.  QUANTITATIVE FUNCTIONAL IMAGING AND KINETIC STUDIES WITH HIGH‐Z CONTRAST AGENTS USING SYNCHROTRON RADIATION COMPUTED TOMOGRAPHY , 2009, Clinical and experimental pharmacology & physiology.

[52]  B. Yeh,et al.  Dual-energy and low-kVp CT in the abdomen. , 2009, AJR. American journal of roentgenology.

[53]  F. Arfelli,et al.  Mammography imaging studies using a Laue crystal analyzer , 1996 .

[54]  Andreas Fouras,et al.  The past, present, and future of x-ray technology for in vivo imaging of function and form , 2009 .