Water vapor differential absorption lidar development and evaluation.

A ground-based differential absorption lidar (DIAL) system is described which has been developed for vertical range-resolved measurements of water vapor. The laser transmitter consists of a ruby-pumped dye laser, which is operated on a water vapor absorption line at 724.372 nm. Part of the ruby laser output is transmitted simultaneously with the dye laser output to determine atmospheric scattering and attenuation characteristics. The dye and ruby laser backscattered light is collected by a 0.5-m diam telescope, optically separated in the receiver package, and independently detected using photomultiplier tubes. Measurements of vertical water vapor concentration profiles using the DIAL system at night are discussed, and comparisons are made between the water vapor DIAL measurements and data obtained from locally launched rawinsondes. Agreement between these measurements was found to be within the uncertainty of the rawinsonde data to an altitude of 3 km. Theoretical simulations of this measurement were found to give reasonably accurate predictions of the random error of the DIAL measurements. Confidence in these calculations will permit the design of aircraft and Shuttle DIAL systems and experiments using simulation results as the basis for defining lidar system performance requirements.

[1]  W. Grant,et al.  Calibrated remote measurements of SO2 and O3 using atmospheric backscatter , 1975 .

[2]  Remote measurement of NO2 emission from a chemical factory by the differential absorption technique , 1974 .

[3]  U. Brinkmann,et al.  Applications of tunable dye lasers to air pollution detection: Measurements of atmospheric NO2 concentrations by differential absorption , 1974 .

[4]  V. Derr,et al.  A comparison of remote sensing of the clear atmosphere by optical, radio, and acoustic radar techniques. , 1970, Applied optics.

[5]  N. U. Mayall Kitt Peak National Observatory , 1964 .

[6]  C. Wang Application of lasers in atmospheric probing , 1974 .

[7]  A theoretical/experimental program to develop active optical pollution sensors , 1977 .

[8]  S H Melfi,et al.  Remote measurements of the atmosphere using Raman scattering. , 1972, Applied optics.

[9]  R L Byer,et al.  Pollutant detection by absorption using mie scattering and topographic targets as retroreflectors. , 1973, Applied optics.

[10]  R. C. Robbins,et al.  Calibrated remote measurement of NO2 using the differential‐absorption backscatter technique , 1974 .

[11]  S. H. Melfi,et al.  OBSERVATION OF RAMAN SCATTERING BY WATER VAPOR IN THE ATMOSPHERE , 1969 .

[12]  J. E. van der Laan,et al.  Atmospheric water vapor measurements with an infrared (10‐μm) differential‐absorption lidar system , 1976 .

[13]  J. Cooney,et al.  Comparisons of Water Vapor Profiles Obtained by Radiosonde and Laser Backscatter , 1971 .

[14]  Thomas D. Wilkerson,et al.  Intensities and N2 collision-broadening coefficients measured for selected H2O absorption lines between 715 and 732 nm , 1979 .

[15]  E. Remsberg,et al.  Analysis of differential absorption lidar from the space shuttle. , 1978, Applied optics.

[16]  J. Cooney,et al.  Remote Measurements of Atmospheric Water Vapor Profiles Using the Raman Component of Laser Backscatter , 1970 .