High-resolution ultrahigh-pressure long column reversed-phase liquid chromatography for top-down proteomics.

Separation of proteoforms for global intact protein analysis (i.e. top-down proteomics) has lagged well behind what is achievable for peptides in traditional bottom-up proteomic approach and is becoming a true bottle neck for top-down proteomics. Herein, we report use of long (≥1M) columns containing short alkyl (C1-C4) bonded phases to achieve high-resolution RPLC for separation of proteoforms. At a specific operation pressure limit (i.e., 96.5MPa or 14Kpsi used in this work), column length was found to be the most important factor for achieving maximal resolution separation of proteins when 1.5-5μm particles were used as packings and long columns provided peak capacities greater than 400 for proteoforms derived from a global cell lysate with molecular weights below 50kDa. Larger proteoforms (50-110kDa) were chromatographed on long RPLC columns and detected by MS; however, they cannot be identified yet by tandem mass spectrometry. Our experimental data further demonstrated that long alkyl (e.g., C8 and C18) bonded particles provided high-resolution RPLC for <10kDa proteoforms, not efficient for separation of global proteoforms. Reversed-phase particles with porous, nonporous, and superficially porous surfaces were systematically investigated for high-resolution RPLC. Pore size (200-400Å) and the surface structure (porous and superficially porous) of particles was found to have minor influences on high-resolution RPLC of proteoforms. RPLC presented herein enabled confident identification of ∼900 proteoforms (1% FDR) for a low-microgram quantity of proteomic samples using a single RPLC-MS/MS analysis. The level of RPLC performance attained in this work is close to that typically realized in bottom-up proteomics, and broadly useful when applying e.g., the single-stage MS accurate mass tag approach, but less effective when combined with current tandem MS. Our initial data indicate that MS detection and fragmentation inefficiencies provided by current high-resolution mass spectrometers are key challenges for characterization of larger proteoforms.

[1]  Milton L. Lee,et al.  General Equation for Peak Capacity in Column Chromatography , 1998 .

[2]  B. M. Greenberg,et al.  Top-down mass spectrometry on tissue extracts and biofluids with isoelectric focusing and superficially porous silica liquid chromatography. , 2013, Analytical chemistry.

[3]  Jared B Shaw,et al.  Complete protein characterization using top-down mass spectrometry and ultraviolet photodissociation. , 2013, Journal of the American Chemical Society.

[4]  Ronald J Moore,et al.  Strategy for degradomic-peptidomic analysis of human blood plasma. , 2010, Journal of proteome research.

[5]  E. Nice,et al.  Factors influencing chromatography of proteins on short alkylsilane-bonded large pore-size silicas. , 1982, Analytical biochemistry.

[6]  M. Wirth,et al.  RPLC of intact proteins using sub-0.5 μm particles and commercial instrumentation. , 2013, Analytical chemistry.

[7]  J. Gebler,et al.  Implications of column peak capacity on the separation of complex peptide mixtures in single- and two-dimensional high-performance liquid chromatography. , 2004, Journal of chromatography. A.

[8]  Lee Ann McCue,et al.  Identification of Mobile Elements and Pseudogenes in the Shewanella oneidensis MR-1 Genome , 2008, Applied and Environmental Microbiology.

[9]  Ronald J Moore,et al.  Proteome-wide identification of proteins and their modifications with decreased ambiguities and improved false discovery rates using unique sequence tags. , 2008, Analytical chemistry.

[10]  Richard D. Smith,et al.  High-efficiency nanoscale liquid chromatography coupled on-line with mass spectrometry using nanoelectrospray ionization for proteomics. , 2002, Analytical chemistry.

[11]  Richard D. LeDuc,et al.  Mapping Intact Protein Isoforms in Discovery Mode Using Top Down Proteomics , 2011, Nature.

[12]  T. Kinoshita,et al.  Fast protein separation by reversed-phase high-performance liquid chromatography on octadecylsilyl-bonded nonporous silica gel. II. Improvement in recovery of hydrophobic proteins. , 1991, Analytical biochemistry.

[13]  C. Huber,et al.  High‐efficiency nano‐ and micro‐HPLC – High‐resolution Orbitrap‐MS platform for top‐down proteomics , 2010, Proteomics.

[14]  Ronald J. Moore,et al.  Automated 20 kpsi RPLC-MS and MS/MS with chromatographic peak capacities of 1000-1500 and capabilities in proteomics and metabolomics. , 2005, Analytical chemistry.

[15]  E. M. Renkin,et al.  FILTRATION, DIFFUSION, AND MOLECULAR SIEVING THROUGH POROUS CELLULOSE MEMBRANES , 1954, The Journal of general physiology.

[16]  Richard D. Smith,et al.  De novo sequencing of unique sequence tags for discovery of post-translational modifications of proteins. , 2008, Analytical chemistry.

[17]  Nuno Bandeira,et al.  False discovery rates in spectral identification , 2012, BMC Bioinformatics.

[18]  Ronald J. Moore,et al.  Effectiveness of CID, HCD, and ETD with FT MS/MS for degradomic-peptidomic analysis: comparison of peptide identification methods. , 2011, Journal of proteome research.

[19]  F. Regnier,et al.  Reversed-phase supports for th resolution of large denatured protein fragments. , 1981, Journal of chromatography.

[20]  Steven M. Patrie,et al.  Sensitive and reproducible intact mass analysis of complex protein mixtures with superficially porous capillary reversed-phase liquid chromatography mass spectrometry. , 2011, Analytical chemistry.

[21]  Glenwyn D. Kemp,et al.  High-resolution separations of protein isoforms with liquid chromatography time-of-flight mass spectrometry using polymer monolithic capillary columns. , 2011, Journal of chromatography. A.

[22]  A. Capriotti,et al.  Intact protein separation by chromatographic and/or electrophoretic techniques for top-down proteomics. , 2011, Journal of chromatography. A.

[23]  R. Aebersold,et al.  Analysis of protein complexes using mass spectrometry , 2007, Nature Reviews Molecular Cell Biology.

[24]  E. Nice,et al.  Comparison of short and ultrashort-chain alkylsilane-bonded silicas for the high-performance liquid chromatography of proteins by hydrophobic interaction methods , 1981 .

[25]  K. Tweeten,et al.  Reversed-phase chromatography of proteins on resin-based wide-pore packings , 1986 .

[26]  Ronald J. Moore,et al.  Blood Peptidome-Degradome Profile of Breast Cancer , 2010, PloS one.

[27]  J. Yates,et al.  Protein analysis by shotgun/bottom-up proteomics. , 2013, Chemical reviews.

[28]  M. Wirth,et al.  Efficient Separations of Intact Proteins Using Slip-Flow with Nano-Liquid Chromatography–Mass Spectrometry , 2014, Analytical chemistry.