Intraoperative Damage Monitoring of Endoclamp Balloon Expansion Using Real-Time Finite Element Modeling

Endovascular clamping can be achieved by means of intraluminal occlusion with an Endoclamp balloon. Circumventing the need for opening the thoracic cage provides significant benefits in terms of reducing trauma for the patient. This procedure, however, induces risks of damage to the aortic lumen by way of over-expansion of the balloon, exposing the aortic tissue to unsafe levels of loading. Accurate estimates of the induced stress and consequent damage are required intraoperatively to warn the surgeon and mitigate the risk of injury.This paper proposes a method for intraoperative monitoring of the inflicted damage to the arterial tissue, by means of finite element modeling. The Total Lagrangian Explicit Dynamic (TLED) finite element (FE) formulation, capable of handling geometric and material nonlinearities, is used. A 2D plane strain formulation is used to additionally simplify and speed up the execution time by reducing the number of degrees of freedom involved, meanwhile retaining sufficient accuracy for the proposed application. A material model incorporating damage as an internal variable allowed tracking of the degree of injury to the artery. The large amount of computation needed to solve for the stress field is relieved by using dedicated massively parallel hardware. An Nvidia CUDA GPGPU (General Purpose Graphics Processing Unit) is employed to parallelize critical portions of the TLED algorithm. The accuracy of the solution is verified against an industry-proven FE package Abaqus. Results show significant speed-ups compared to Abaqus, thereby retaining a sufficient degree of accuracy.

[1]  O. C. Zienkiewicz,et al.  The Finite Element Method for Solid and Structural Mechanics , 2013 .

[2]  Karol Miller,et al.  Suite of finite element algorithms for accurate computation of soft tissue deformation for surgical simulation , 2009, Medical Image Anal..

[3]  G. Holzapfel,et al.  Arterial clamping: finite element simulation and in vivo validation. , 2012, Journal of the mechanical behavior of biomedical materials.

[4]  Bert Willaert,et al.  In vivo soft tissue damage assessment for applications in surgery. , 2010, Medical engineering & physics.

[5]  R. Ogden,et al.  A New Constitutive Framework for Arterial Wall Mechanics and a Comparative Study of Material Models , 2000 .

[6]  Ellen Kuhl,et al.  A three-constituent damage model for arterial clamping in computer-assisted surgery , 2012, Biomechanics and Modeling in Mechanobiology.

[7]  K. Miller,et al.  Total Lagrangian explicit dynamics finite element algorithm for computing soft tissue deformation , 2006 .

[8]  R. Ogden,et al.  Hyperelastic modelling of arterial layers with distributed collagen fibre orientations , 2006, Journal of The Royal Society Interface.

[9]  T. Belytschko,et al.  Computational Methods for Transient Analysis , 1985 .

[10]  F. Casselman,et al.  Mitral Valve Surgery Can Now Routinely Be Performed Endoscopically , 2003, Circulation.

[11]  J. C. Simo,et al.  Strain- and stress-based continuum damage models—I. Formulation , 1987 .

[12]  Karol Miller,et al.  Patient-specific non-linear finite element modelling for predicting soft organ deformation in real-time: application to non-rigid neuroimage registration. , 2010, Progress in biophysics and molecular biology.

[13]  Françoise Thivolet,et al.  Comparison between 3 aortic clamps for video-assisted cardiac surgery: a histological study in a pig model. , 2006, The heart surgery forum.