Wind Turbine Inverter Robust Loop-Shaping Control Subject to Grid Interaction Effects

An H∞ robust control of wind turbine (WT) inverters employing an inductor-capacitor-inductor (LCL) filter is proposed in this paper. The controller dynamics are designed for selective harmonic filtering in an offshore transmission network subject to parameter perturbations. Parameter uncertainty in the network originates from the grid and the number of WTs connected. Power converter-based turbines inject harmonic currents, which are attenuated by passive filters. A robust high-order active filter controller is proposed to complement the passive filtering. The H∞ design of the control loop enables desired tracking with integral effect while bounding the induced change. The design was tested in an aggregated model of the London Array offshore wind power plant and compared with traditional Proportional-Integral (PI) controller designs. Robust stability and performance and a reduction of control effort by 25% are obtained over the full envelope of operation.

[1]  Ming Cheng,et al.  Modeling, Analysis, and Design of Multifunction Grid-Interfaced Inverters With Output LCL Filter , 2014, IEEE Transactions on Power Electronics.

[2]  G. Weiss,et al.  H/sup /spl infin// repetitive control of DC-AC converters in microgrids , 2004, IEEE Transactions on Power Electronics.

[3]  E. Muljadi,et al.  Equivalencing the collector system of a large wind power plant , 2006, 2006 IEEE Power Engineering Society General Meeting.

[4]  Dierk Schröder,et al.  Elektrische Antriebe - Regelung von Antriebssystemen , 2001 .

[6]  Esam Alansari Control in Power Electronics , 2016 .

[7]  Jun Liang,et al.  H ∞ repetitive control of DC-AC converters in micro-grids ∗ , 2022 .

[8]  Zhengyou He,et al.  Potential Harmonic Resonance Impacts of PV Inverter Filters on Distribution Systems , 2015, IEEE Transactions on Sustainable Energy.

[9]  B. Chitti Babu,et al.  Experimental study on adaptive hysteresis current controller for inverter-interfaced 1-Φ grid connected system , 2011, 2011 Annual IEEE India Conference.

[10]  Seung-Ki Sul,et al.  LCL filter design for grid-connected voltage-source converters in high power systems , 2012, 2012 IEEE Energy Conversion Congress and Exposition (ECCE).

[11]  V. Blasko,et al.  A novel control to actively damp resonance in input LC filter of a three phase voltage source converter , 1996, Proceedings of Applied Power Electronics Conference. APEC '96.

[12]  Pereira Heverton Augusto,et al.  A comparative analysis of wind turbine technologies in focus on the grid integration , 2010, 2010 9th IEEE/IAS International Conference on Industry Applications - INDUSCON 2010.

[13]  H. Pinheiro,et al.  Design and Implementation of a Robust Current Controller for VSI Connected to the Grid Through an LCL Filter , 2009, IEEE Transactions on Power Electronics.

[14]  Il-Song Kim,et al.  Sliding mode controller for the single-phase grid-connected photovoltaic system , 2006 .

[15]  Karl Johan Åström,et al.  PID Controllers: Theory, Design, and Tuning , 1995 .

[16]  F.W. Fuchs,et al.  Active damping of LCL-filter resonance based on virtual resistor for PWM rectifiers — stability analysis with different filter parameters , 2008, 2008 IEEE Power Electronics Specialists Conference.

[17]  M. Safiuddin,et al.  Magnitude and symmetric optimum criterion for the design of linear control systems-what is it and does it compare with the others? , 1988, Conference Record of the 1988 IEEE Industry Applications Society Annual Meeting.

[18]  Frede Blaabjerg,et al.  Proportional-resonant controllers and filters for grid-connected voltage-source converters , 2006 .

[19]  Alvaro Luna,et al.  Harmonic Compensation Analysis in Offshore Wind Power Plants Using Hybrid Filters , 2014, IEEE Transactions on Industry Applications.

[20]  S.V. Araujo,et al.  LCL filter design for grid-connected NPC inverters in offshore wind turbines , 2007, 2007 7th Internatonal Conference on Power Electronics.

[21]  Richard Gagnon,et al.  Generic Equivalent Collector System Parameters for Large Wind Power Plants , 2011, IEEE Transactions on Energy Conversion.

[22]  M. Liserre,et al.  A new control structure for grid-connected LCL PV inverters with zero steady-state error and selective harmonic compensation , 2004, Nineteenth Annual IEEE Applied Power Electronics Conference and Exposition, 2004. APEC '04..

[23]  M. Liserre,et al.  Multiple harmonics control for three-phase grid converter systems with the use of PI-RES current controller in a rotating frame , 2006, IEEE Transactions on Power Electronics.

[24]  Rogelio Lozano,et al.  Adaptive Control: Algorithms, Analysis and Applications , 2011 .

[25]  Mehdi Niroomand,et al.  Frequency adaptive repetitive control of grid connected inverter for wind turbine applications , 2013, 2013 21st Iranian Conference on Electrical Engineering (ICEE).

[26]  J. A. Solsona,et al.  Performance Improvement of Full-Converter Wind Turbines Under Distorted Conditions , 2013, IEEE Transactions on Sustainable Energy.

[27]  M. Liserre,et al.  Design and control of an LCL-filter based three-phase active rectifier , 2001, Conference Record of the 2001 IEEE Industry Applications Conference. 36th IAS Annual Meeting (Cat. No.01CH37248).

[28]  J. Svensson,et al.  Control of a voltage-source converter connected to the grid through an LCL-filter-application to active filtering , 1998, PESC 98 Record. 29th Annual IEEE Power Electronics Specialists Conference (Cat. No.98CH36196).

[29]  Donald Grahame Holmes,et al.  Grid current regulation of a three-phase voltage source inverter with an LCL input filter , 2003 .

[30]  Y. A-R I. Mohamed,et al.  Robust Line-Voltage Sensorless Control and Synchronization of LCL -Filtered Distributed Generation Inverters for High Power Quality Grid Connection , 2012, IEEE Transactions on Power Electronics.

[31]  Dierk Schröder,et al.  Elektrische Antriebe 2 , 1995 .

[32]  Frede Blaabjerg,et al.  Control in Power Electronics: selected problems , 2002 .

[33]  Steven E. Widergren,et al.  An Orderly Transition to a Transformed Electricity System , 2010, IEEE Transactions on Smart Grid.

[34]  Frede Blaabjerg,et al.  Comparative analysis of the selective resonant LCL and LCL plus trap filters , 2014, 2014 International Conference on Optimization of Electrical and Electronic Equipment (OPTIM).

[35]  Jon Are Suul,et al.  Understanding of tuning techniques of converter controllers for VSC-HVDC , 2008 .

[36]  Ian Postlethwaite,et al.  Multivariable Feedback Control: Analysis and Design , 1996 .

[37]  Thomas A. Lipo,et al.  Pulse Width Modulation for Power Converters: Principles and Practice , 2003 .

[38]  S. D. Haan,et al.  Electrical and Control Aspects of Offshore Wind Farms II (Erao II). Volume 1: Dynamic models of wind farms , 2004 .

[39]  Josep M. Guerrero,et al.  Analysis, Design, and Experimental Verification of a Synchronous Reference Frame Voltage Control for Single-Phase Inverters , 2014, IEEE Transactions on Industrial Electronics.

[40]  Manfred Morari,et al.  A model predictive control approach to reducing low order harmonics in grid inverters with LCL filters , 2013, IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society.

[41]  Lukasz Hubert Kocewiak,et al.  Harmonic Analysis of Offshore Wind Farms with Full Converter Wind Turbines , 2009 .