A wireless 8-channel ECG biopotential acquisition system for dry electrodes

A wireless 8-channel biopotential acquisition system for capturing electrocardiogram (ECG) using dry electrodes is presented. The ECG system consists of copper electrodes, a micropowered 8-channel custom ASIC, and an off-the-shelf microprocessor and bluetooth radio. Each analog channel of the custom ECG front-end is composed of a chopper-modulated instrumentation amplifier (CMIA) with chopping spike filter (CSF), a programmable gain amplifier (PGA), and a output buffer. Implemented in standard a 0.35 μm CMOS technology, the ECG front-end consumes 101 μA from a 2.7 V supply, occupying 5 mm2 of chip area. Measurement results show an input impedance of 1 G Ω, an input-referred noise of 0.97 μVrms (0.5 ~ 100 Hz), and a CMRR of 114 dB. Finally, a complete wireless 8-channel ECG monitoring system incorporating this analog front-end is demonstrated, showing successful recordings of a capture ECG waveform using a smart phone.

[1]  Hui Zhang,et al.  An 8-channel readout front-end for long-term sleep quality monitoring , 2011, 2011 IEEE Biomedical Circuits and Systems Conference (BioCAS).

[2]  Refet Firat Yazicioglu,et al.  A 60 $\mu$W 60 nV/$\surd$Hz Readout Front-End for Portable Biopotential Acquisition Systems , 2007, IEEE Journal of Solid-State Circuits.

[3]  Yong Lian,et al.  A 1-V 450-nW fully integrated biomedical sensor interface system , 2008, 2008 IEEE Symposium on VLSI Circuits.

[4]  Refet Firat Yazicioglu,et al.  A 60/spl mu/W 60 nV/Hz Readout Front-End for Portable Biopotential Acquisition Systems , 2006, 2006 IEEE International Solid State Circuits Conference - Digest of Technical Papers.

[5]  Refet Firat Yazicioglu,et al.  A $160~\mu {\rm W}$ 8-Channel Active Electrode System for EEG Monitoring , 2011, IEEE Transactions on Biomedical Circuits and Systems.

[6]  D. Dubin Rapid Interpretation of EKG's , 1977 .

[7]  R.R. Harrison,et al.  A Low-Power Integrated Circuit for a Wireless 100-Electrode Neural Recording System , 2006, IEEE Journal of Solid-State Circuits.

[8]  K.-P. Hoffmann,et al.  Flexible dry surface-electrodes for ECG long-term monitoring , 2007, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[9]  E. Nemati,et al.  A wireless wearable ECG sensor for long-term applications , 2012, IEEE Communications Magazine.

[10]  Gabor C. Temes,et al.  Circuit techniques for reducing the effects of op-amp imperfections: autozeroing, correlated double sampling, and chopper stabilization , 1996, Proc. IEEE.