Real-Time Microscope-Integrated OCT to Improve Visualization in DSAEK for Advanced Bullous Keratopathy

Purpose: To report the intraoperative use of microscope-integrated optical coherence tomography (MIOCT) to enable visualization for Descemet's stripping automated endothelial keratoplasty (DSAEK) in 2 patients with advanced bullous keratopathy. Methods: Patient 1 was an 83-year-old female and patient 2 was a 28-year-old male both with limited vision and significant pain from bullous keratopathy who underwent palliative DSAEK. Because of the severity and chronicity of the corneal decompensation in both patients, the view past the anterior cornea was negligible using standard microscope illumination techniques. We used spectral-domain (Patient 1) and swept-source (Patient 2) MIOCT, both of which rely on infrared illumination, to visualize key parts of the DSAEK procedure. Results: Graft insertion, unfolding, tamponade, and attachment could be dynamically visualized intraoperatively despite the nearly opaque nature of the host corneas. Postoperatively, the grafts remained attached with significant corneal clearing, and there was improvement in visual acuity, and pain relief for both patients. Conclusions: MIOCT is a valuable tool for the corneal surgeon, allowing for DSAEK to be successfully performed even when the surgical microscope view is limited from severe corneal edema, as is often the case in patients with advanced bullous keratopathy. By using MIOCT, these patients can benefit from the advantages of DSAEK despite a clinically opaque cornea, which would otherwise be treated with a penetrating keratoplasty.

[1]  Joseph A. Izatt,et al.  PRECLINICAL EVALUATION AND INTRAOPERATIVE HUMAN RETINAL IMAGING WITH A HIGH-RESOLUTION MICROSCOPE-INTEGRATED SPECTRAL DOMAIN OPTICAL COHERENCE TOMOGRAPHY DEVICE , 2013, Retina.

[2]  Peter K Kaiser,et al.  Intraoperative optical coherence tomography using the RESCAN 700: preliminary results from the DISCOVER study , 2014, British Journal of Ophthalmology.

[3]  M. Gorovoy,et al.  Long-term Results of Descemet Stripping Automated Endothelial Keratoplasty , 2011, Cornea.

[4]  J. Mehta,et al.  Modified air-assisted descemetorhexis for Descemet-stripping automated endothelial keratoplasty. , 2008, Journal of cataract and refractive surgery.

[5]  Sashia Bak-Nielsen,et al.  Graft Rejection and Graft Failure After Penetrating Keratoplasty or Posterior Lamellar Keratoplasty for Fuchs Endothelial Dystrophy , 2013, Cornea.

[6]  I. Bahar,et al.  Retrospective Contralateral Study Comparing Descemet Stripping Automated Endothelial Keratoplasty With Penetrating Keratoplasty , 2009, Cornea.

[7]  H. Menegay,et al.  Descemet's stripping automated endothelial keratoplasty: three-year graft and endothelial cell survival compared with penetrating keratoplasty. , 2013, Ophthalmology.

[8]  K. Nishida,et al.  Chandelier Illumination for Use During Descemet Stripping Automated Endothelial Keratoplasty in Patients With Advanced Bullous Keratopathy , 2011, Cornea.

[9]  Y. El-Shabrawi,et al.  Lamellar corneal dissection for visualization of the anterior chamber before triple procedure , 2007, Eye.

[10]  M. Terry,et al.  Three-year visual acuity outcomes after Descemet's stripping automated endothelial keratoplasty. , 2012, Ophthalmology.