Limitations of quasi-static estimation of human joint loading during locomotion

The forces and moments at the ankle, knee and hip joints of the human lower limbs are divided into static and inertial components. They are calculated for various activities ranging from slow walking to running. The relative roles of these two components in the ‘total’ joint loads are studied, and the limitations of using a quasi-static analysis approach for joint load approximation are discussed. The results indicate that the static loads only reflect the gravitational and external reactions between the body and the environment, whereas the inertial loads provide dynamic information on each body segment involved. The effect of the inertial forces and moments becomes more important as the speed of locomotion increases; where the more proximal joints in the human lower extremity are concerned; and where the shear components of the force and moment are of interest. On the other hand, it seems that most of the joint moments in the lower extremity during walking and even running could reasonably be approximated by static components.

[1]  R. Wells The projection of the ground reaction force as a predictor of internal joint moments. , 1981, Bulletin of prosthetics research.

[2]  Y. Pai,et al.  Dynamic transitions in stance support accompanying leg flexion movements in man , 1990, Experimental Brain Research.

[3]  B. Bresler The Forces and Moments in the Leg During Level Walking , 1950, Journal of Fluids Engineering.

[4]  J. Dickinson,et al.  The measurement of shock waves following heel strike while running. , 1985, Journal of biomechanics.

[5]  Wells Rp The projection of the ground reaction force as a predictor of internal joint moments. , 1981 .

[6]  A Cappozzo,et al.  A polycentric knee-ankle mechanism for above-knee prostheses. , 1980, Journal of biomechanics.

[7]  H. Lanshammar On precision limits for derivatives numerically calculated from noisy data. , 1982, Journal of biomechanics.

[8]  J R Morris,et al.  Accelerometry--a technique for the measurement of human body movements. , 1973, Journal of biomechanics.

[9]  W B Rowe,et al.  A bioengineering analysis of human muscle and joint forces in the lower limbs during running. , 1986, Journal of sports sciences.

[10]  Z Ladin,et al.  The kinematometer--an integrated kinematic sensor for kinesiological measurements. , 1993, Journal of biomechanical engineering.

[11]  Z Ladin,et al.  Combining position and acceleration measurements for joint force estimation. , 1991, Journal of biomechanics.

[12]  M W Whittle Calibration and performance of a 3-dimensional television system for kinematic analysis. , 1982, Journal of biomechanics.

[13]  J. Mcelhaney,et al.  A system to measure the forces and moments at the knee and hip during level walking , 1984, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[14]  G. Street Biomechanics IX-B , 1985 .