On the estimation of backscatter coefficients using single-element focused transducers.

The ultimate goal of quantitative ultrasound (QUS) imaging methods based on backscatter coefficient (BSC) estimates is to obtain system-independent structural information about samples. In the current study, three BSC estimation methods were compared and evaluated using the same backscattered pressure datasets in order to assess their consistency. BSC estimates were obtained from two phantoms with embedded glass spheres and compared to theoretical BSCs calculated using size distributions estimated using optical microscopy. Effective scatterer diameter and concentration estimates of the glass spheres were also obtained from the estimated BSCs. One estimation method needed to be compensated by more than an order of magnitude in amplitude in order to produce BSCs comparable to the other two methods. All calibration methods introduced different frequency-dependent effects, which could have noticeable effects on the bias of QUS estimates derived from experimental BSCs. Although in most cases the experimental QUS estimates obtained with all three methods were observed to differ by less than 10%, larger differences are expected depending on both the pressure focusing gain of the transducer (proportional to the ratio of the square of the aperture radius to the product of the wavelength and focal length) and ka range used in the estimation.

[1]  R C Waag,et al.  Compensation for receiver bandpass effects on ultrasonic backscatter power spectra using a random medium reference. , 1988, The Journal of the Acoustical Society of America.

[2]  E J Feleppa,et al.  Diagnostic spectrum analysis in ophthalmology: a physical perspective. , 1986, Ultrasound in medicine & biology.

[3]  E. Feleppa,et al.  Theoretical framework for spectrum analysis in ultrasonic tissue characterization. , 1983, The Journal of the Acoustical Society of America.

[4]  F. Lizzi,et al.  Ultrasonic spectrum analysis for tissue assays and therapy evaluation , 1997 .

[5]  H. O'neil Theory of Focusing Radiators , 1949 .

[6]  K. Parker,et al.  Acoustic coupling from a focused transducer to a flat plate and back to the transducer. , 1993, The Journal of the Acoustical Society of America.

[7]  Michael L. Oelze,et al.  Erratum: “Frequency-dependent attenuation-compensation functions for ultrasonic signals backscattered from random media” [J. Acoust. Soc. Am. 111, 2308–2319 (2002)] , 2003 .

[8]  J. Faran Sound Scattering by Solid Cylinders and Spheres , 1951 .

[9]  K J Parker,et al.  Radiation pattern of a focused transducer: a numerically convergent solution. , 1993, The Journal of the Acoustical Society of America.

[10]  Yasuhiko Ozawa,et al.  Spectral analysis of echoes for backscattering coefficient measurement , 1985 .

[11]  William D O'Brien,et al.  Frequency-dependent attenuation-compensation functions for ultrasonic signals backscattered from random media. , 2002, The Journal of the Acoustical Society of America.

[12]  M.F. Insana,et al.  Backscatter coefficient estimation using array transducers , 1994, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[13]  Bernard G. Lucas,et al.  The field of a focusing source , 1982 .

[14]  John M. Reid,et al.  Analysis and measurement of ultrasound backscattering from an ensemble of scatterers excited by sine‐wave bursts , 1973 .

[15]  T. Varghese,et al.  Correlation of ultrasonic scatterer size estimates for the statistical analysis and optimization of angular compounding. , 2004, The Journal of the Acoustical Society of America.

[16]  William D O'Brien,et al.  Characterization of tissue microstructure using ultrasonic backscatter: theory and technique for optimization using a Gaussian form factor. , 2002, The Journal of the Acoustical Society of America.

[17]  M. Insana,et al.  Error bounds on ultrasonic scatterer size estimates. , 1996, The Journal of the Acoustical Society of America.

[18]  R C Waag,et al.  Ultrasonic scattering properties of three random media with implications for tissue characterization. , 1984, The Journal of the Acoustical Society of America.

[19]  E. Madsen,et al.  Interlaboratory Comparison of Ultrasonic Backscatter Coefficient Measurements From 2 to 9 MHz , 2005, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[20]  R. F. Wagner,et al.  Describing small-scale structure in random media using pulse-echo ultrasound. , 1990, The Journal of the Acoustical Society of America.

[21]  Ronald H. Silverman,et al.  Ultrasonic spectrum analysis for tissue assays and therapy evaluation , 1997, Int. J. Imaging Syst. Technol..

[22]  E L Madsen,et al.  Estimating the spatial autocorrelation function for ultrasound scatterers in isotropic media. , 1998, Medical physics.

[23]  J. G. Miller,et al.  Interlaboratory comparison of ultrasonic backscatter, attenuation, and speed measurements. , 1999, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[24]  E. Madsen,et al.  Interlaboratory Comparison of Backscatter Coefficient Estimates for Tissue-Mimicking Phantoms: , 2010 .

[25]  Guy Cloutier,et al.  Ultrasound characterization of red blood cell aggregation with intervening attenuating tissue-mimicking phantoms. , 2010, The Journal of the Acoustical Society of America.

[26]  G Kossoff,et al.  Analysis of focusing action of spherically curved transducers. , 1979, Ultrasound in medicine & biology.

[27]  Michael F. Insana,et al.  High speed quantitative imaging over extended fields of view (medical ultrasound) , 1989, Proceedings., IEEE Ultrasonics Symposium,.

[28]  E. Feleppa,et al.  Relationship of Ultrasonic Spectral Parameters to Features of Tissue Microstructure , 1987, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[29]  E. Madsen,et al.  Method of data reduction for accurate determination of acoustic backscatter coefficients. , 1984, The Journal of the Acoustical Society of America.

[30]  T J Hall,et al.  Parametric Ultrasound Imaging from Backscatter Coefficient Measurements: Image Formation and Interpretation , 1990, Ultrasonic imaging.

[31]  Robert Hickling,et al.  Analysis of Echoes from a Solid Elastic Sphere in Water , 1962 .

[32]  M. O’Donnell,et al.  Quantitative broadband ultrasonic backscatter: An approach to nondestructive evaluation in acoustically inhomogeneous materials , 1981 .

[33]  J. G. Mottley,et al.  The measurement of backscatter coefficient from a broadband pulse-echo system: a new formulation , 1997, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[34]  F. Foster,et al.  Frequency dependence of ultrasound attenuation and backscatter in breast tissue. , 1986, Ultrasound in medicine & biology.

[35]  T. Varghese,et al.  Statistics of ultrasonic scatterer size estimation with a reference phantom. , 2003, The Journal of the Acoustical Society of America.