Photon-counting Detector CT: System Design and Clinical Applications of an Emerging Technology.

Photon-counting detector (PCD) CT is an emerging technology that has shown tremendous progress in the last decade. Various types of PCD CT systems have been developed to investigate the benefits of this technology, which include reduced electronic noise, increased contrast-to-noise ratio with iodinated contrast material and radiation dose efficiency, reduced beam-hardening and metal artifacts, extremely high spatial resolution (33 line pairs per centimeter), simultaneous multienergy data acquisition, and the ability to image with and differentiate among multiple CT contrast agents. PCD technology is described and compared with conventional CT detector technology. With the use of a whole-body research PCD CT system as an example, PCD technology and its use for in vivo high-spatial-resolution multienergy CT imaging is discussed. The potential clinical applications, diagnostic benefits, and challenges associated with this technology are then discussed, and examples with phantom, animal, and patient studies are provided. ©RSNA, 2019.

[1]  Armando Manduca,et al.  An effective noise reduction method for multi‐energy CT images that exploit spatio‐spectral features , 2017, Medical physics.

[2]  Franz Pfeiffer,et al.  Experimental feasibility of spectral photon-counting computed tomography with two contrast agents for the detection of endoleaks following endovascular aortic repair , 2018, European Radiology.

[3]  A. Mohammad-Djafari,et al.  A full-spectral Bayesian reconstruction approach based on the material decomposition model applied in dual-energy computed tomography. , 2013, Medical physics.

[4]  A. Butler,et al.  Spectroscopic (multi-energy) CT distinguishes iodine and barium contrast material in MICE , 2010, European Radiology.

[5]  Michael Campbell,et al.  Characterisation of an epitaxial GaAs/Medipix2 detector using fluorescence photons , 2008 .

[6]  Jeffrey A. Fessler,et al.  Multi-Material Decomposition Using Statistical Image Reconstruction for Spectral CT , 2014, IEEE Transactions on Medical Imaging.

[7]  J. Schlomka,et al.  Experimental feasibility of multi-energy photon-counting K-edge imaging in pre-clinical computed tomography , 2008, Physics in medicine and biology.

[8]  Felix K. Kopp,et al.  Simultaneous dual-contrast multi-phase liver imaging using spectral photon-counting computed tomography: a proof-of-concept study , 2017, European Radiology Experimental.

[9]  Polad M Shikhaliev Photon counting spectral CT: improved material decomposition with K-edge-filtered x-rays. , 2012, Physics in medicine and biology.

[10]  M. Danielsson,et al.  Photon-counting spectral computed tomography using silicon strip detectors: a feasibility study , 2010, Physics in medicine and biology.

[11]  K. Taguchi,et al.  Vision 20/20: Single photon counting x-ray detectors in medical imaging. , 2013, Medical physics.

[12]  Franz Pfeiffer,et al.  Spectral Photon-counting CT: Initial Experience with Dual-Contrast Agent K-Edge Colonography. , 2017, Radiology.

[13]  P. Shikhaliev,et al.  Photon counting spectral breast CT: effect of adaptive filtration on CT numbers, noise, and contrast to noise ratio. , 2013, Medical physics.

[14]  Xiaochuan Pan,et al.  An algorithm for constrained one-step inversion of spectral CT data , 2015, Physics in medicine and biology.

[15]  Shuai Leng,et al.  Spectral performance of a whole-body research photon counting detector CT: quantitative accuracy in derived image sets , 2017, Physics in medicine and biology.

[16]  D. P. Clark,et al.  Spectral imaging of iodine and gadolinium nanoparticles using dual-energy CT , 2018, Medical Imaging.

[17]  E. Ritman,et al.  Human Imaging With Photon Counting–Based Computed Tomography at Clinical Dose Levels: Contrast-to-Noise Ratio and Cadaver Studies , 2016, Investigative radiology.

[18]  Rafidah Zainon,et al.  Toward quantifying the composition of soft tissues by spectral CT with Medipix3. , 2012, Medical physics.

[19]  Michael Campbell,et al.  How spectroscopic x-ray imaging benefits from inter-pixel communication. , 2014, Physics in medicine and biology.

[20]  K. Ghaghada,et al.  Computed Tomography Imaging of Solid Tumors Using a Liposomal-Iodine Contrast Agent in Companion Dogs with Naturally Occurring Cancer , 2016, PloS one.

[21]  Anthony P. H. Butler,et al.  Image Reconstruction for Hybrid True-Color Micro-CT , 2012, IEEE Transactions on Biomedical Engineering.

[22]  Gary J. Hooper,et al.  Quantitative imaging of excised osteoarthritic cartilage using spectral CT , 2016, European Radiology.

[23]  Ewald Roessl,et al.  Multicolor spectral photon-counting computed tomography: in vivo dual contrast imaging with a high count rate scanner , 2017, Scientific Reports.

[24]  Franz Pfeiffer,et al.  Joint Statistical Iterative Material Image Reconstruction for Spectral Computed Tomography Using a Semi-Empirical Forward Model , 2018, IEEE Transactions on Medical Imaging.

[25]  E. Roessl,et al.  K-edge imaging in x-ray computed tomography using multi-bin photon counting detectors , 2007, Physics in medicine and biology.

[26]  Katharina Hahn,et al.  Dose-efficient ultrahigh-resolution scan mode using a photon counting detector computed tomography system , 2016, Journal of medical imaging.

[27]  Yoad Yagil,et al.  State of the Art of CT Detectors and Sources: A Literature Review , 2013, Current Radiology Reports.

[28]  Taly Gilat Schmidt,et al.  Optimal "image-based" weighting for energy-resolved CT. , 2009, Medical physics.

[29]  Axel Thran,et al.  An early investigation of ytterbium nanocolloids for selective and quantitative "multicolor" spectral CT imaging. , 2012, ACS nano.

[30]  Thorsten M. Buzug,et al.  Polychromatic Iterative Statistical Material Image Reconstruction for Photon-Counting Computed Tomography , 2016, Int. J. Biomed. Imaging.

[31]  T. Johnson,et al.  Dual-energy CT: general principles. , 2012, AJR. American journal of roentgenology.

[32]  Polad M Shikhaliev Soft tissue imaging with photon counting spectroscopic CT. , 2015, Physics in medicine and biology.

[33]  Edgar Kraft,et al.  A research prototype system for quantum-counting clinical CT , 2010, Medical Imaging.

[34]  M. Reiser,et al.  Material differentiation by dual energy CT: initial experience , 2007, European Radiology.

[35]  P. Shikhaliev,et al.  Photon counting spectral CT versus conventional CT: comparative evaluation for breast imaging application , 2011, Physics in medicine and biology.

[36]  David P. Cormode,et al.  Review of an initial experience with an experimental spectral photon-counting computed tomography system , 2017 .

[37]  Darin P Clark,et al.  A neural network-based method for spectral distortion correction in photon counting x-ray CT , 2016, Physics in medicine and biology.

[38]  Shuai Leng,et al.  Maximizing Iodine Contrast-to-Noise Ratios in Abdominal CT Imaging through Use of Energy Domain Noise Reduction and Virtual Monoenergetic Dual-Energy CT. , 2015, Radiology.

[39]  Shuai Leng,et al.  Electronic noise in CT detectors: Impact on image noise and artifacts. , 2013, AJR. American journal of roentgenology.

[40]  J. Iwanczyk,et al.  Photon Counting Energy Dispersive Detector Arrays for X-ray Imaging , 2007, IEEE Transactions on Nuclear Science.

[41]  C. McCollough,et al.  Dual- and Multi-Energy CT: Principles, Technical Approaches, and Clinical Applications. , 2015, Radiology.

[42]  Cheng Xu,et al.  Energy resolution of a segmented silicon strip detector for photon-counting spectral CT , 2013 .

[43]  Shuai Leng,et al.  Reducing Image Noise in Computed Tomography (CT) Colonography: Effect of an Integrated Circuit CT Detector , 2014, Journal of computer assisted tomography.

[44]  G. Anton,et al.  The influence of energy weighting on X-ray imaging quality , 2004 .

[45]  Baiyu Chen,et al.  Evaluation of conventional imaging performance in a research whole-body CT system with a photon-counting detector array , 2016, Physics in medicine and biology.

[46]  Feng Zhang,et al.  Charge sharing in common-grid pixelated CdZnTe detectors , 2011 .

[47]  Anthony P. H. Butler,et al.  Hybrid Spectral Micro-CT: System Design, Implementation, and Preliminary Results , 2014, IEEE Transactions on Biomedical Engineering.

[48]  Amir Pourmorteza,et al.  Abdominal Imaging with Contrast-enhanced Photon-counting CT: First Human Experience. , 2016, Radiology.

[49]  D. Cooper,et al.  Three dimensional mapping of strontium in bone by dual energy K-edge subtraction imaging , 2012, Physics in medicine and biology.

[50]  C H McCollough,et al.  Novel ultrahigh resolution data acquisition and image reconstruction for multi-detector row CT. , 2007, Medical physics.

[51]  Ge Wang,et al.  Spectral CT Reconstruction With Image Sparsity and Spectral Mean , 2016, IEEE Transactions on Computational Imaging.

[52]  Polad M Shikhaliev,et al.  Photon counting multienergy x-ray imaging: effect of the characteristic x rays on detector performance. , 2009, Medical physics.

[53]  P. Shikhaliev Computed tomography with energy-resolved detection: a feasibility study , 2008, Physics in medicine and biology.

[54]  Wei Zhou,et al.  150-&mgr;m Spatial Resolution Using Photon-Counting Detector Computed Tomography Technology: Technical Performance and First Patient Images , 2018, Investigative radiology.

[55]  Xuejin Liu,et al.  Count rate performance of a silicon-strip detector for photon-counting spectral CT , 2016 .

[56]  Zhicong Yu,et al.  Spectral prior image constrained compressed sensing (spectral PICCS) for photon-counting computed tomography , 2016, Physics in medicine and biology.

[57]  Thomas Koenig,et al.  Performance of a Medipix3RX Spectroscopic Pixel Detector With a High Resistivity Gallium Arsenide Sensor , 2015, IEEE Transactions on Medical Imaging.

[58]  Axel Thran,et al.  Atherosclerotic Plaque Composition : Analysis with Multicolor CT and Targeted Gold Nanoparticles 1 , 2010 .

[59]  P. Shikhaliev Energy-resolved computed tomography: first experimental results , 2008, Physics in medicine and biology.

[60]  Stefan Ulzheimer,et al.  Dual-contrast agent photon-counting computed tomography of the heart: initial experience , 2017, The International Journal of Cardiovascular Imaging.

[61]  Xiaoqun Zhang,et al.  TICMR: Total Image Constrained Material Reconstruction via Nonlocal Total Variation Regularization for Spectral CT , 2016, IEEE Transactions on Medical Imaging.

[62]  Efstathios Karathanasis,et al.  High-resolution CT vascular imaging using blood pool contrast agents. , 2012, Methodist DeBakey cardiovascular journal.

[63]  C. Svensson,et al.  Preliminary evaluation of a silicon strip detector for photon-counting spectral CT , 2012 .

[64]  Cheng Xu,et al.  Energy-resolved CT imaging with a photon-counting silicon-strip detector. , 2014, Physics in medicine and biology.

[65]  R. Doesburg,et al.  Spectral CT of carotid atherosclerotic plaque: comparison with histology , 2012, European Radiology.

[66]  Katharina Hahn,et al.  Noise performance of low-dose CT: comparison between an energy integrating detector and a photon counting detector using a whole-body research photon counting CT scanner , 2016, Journal of medical imaging.

[67]  Steffen Kappler,et al.  Low-dose lung cancer screening with photon-counting CT: a feasibility study , 2017, Physics in medicine and biology.

[68]  C. Mistretta,et al.  Noise reduction in spectral CT: reducing dose and breaking the trade-off between image noise and energy bin selection. , 2011, Medical physics.

[69]  M. F. Reiser,et al.  Dual energy CT in clinical practice , 2011 .