An opposite view data replacement approach for reducing artifacts due to metallic dental objects.

PURPOSE To present a conceptually new method for metal artifact reduction (MAR) that can be used on patients with multiple objects within the scan plane that are also of small sized along the longitudinal (scanning) direction, such as dental fillings. METHODS The proposed algorithm, named opposite view replacement, achieves MAR by first detecting the projection data affected by metal objects and then replacing the affected projections by the corresponding opposite view projections, which are not affected by metal objects. The authors also applied a fading process to avoid producing any discontinuities in the boundary of the affected projection areas in the sinogram. A skull phantom with and without a variety of dental metal inserts was made to extract the performance metric of the algorithm. A head and neck case, typical of IMRT planning, was also tested. RESULTS The reconstructed CT images based on this new replacement scheme show a significant improvement in image quality for patients with metallic dental objects compared to the MAR algorithms based on the interpolation scheme. For the phantom, the authors showed that the artifact reduction algorithm can efficiently recover the CT numbers in the area next to the metallic objects. CONCLUSIONS The authors presented a new and efficient method for artifact reduction due to multiple small metallic objects. The obtained results from phantoms and clinical cases fully validate the proposed approach.

[1]  W. Kalender,et al.  Reduction of CT artifacts caused by metallic implants. , 1987 .

[2]  S. Zhao,et al.  X-ray CT metal artifact reduction using wavelets: an application for imaging total hip prostheses , 2000, IEEE Transactions on Medical Imaging.

[3]  Mehran Yazdi,et al.  An adaptive approach to metal artifact reduction in helical computed tomography for radiation therapy treatment planning: experimental and clinical studies. , 2005, International journal of radiation oncology, biology, physics.

[4]  Rainer Raupach,et al.  A new algorithm for metal artifact reduction in computed tomography: in vitro and in vivo evaluation after total hip replacement. , 2003, Investigative radiology.

[5]  M. Defrise,et al.  Iterative reconstruction for helical CT: a simulation study. , 1998, Physics in medicine and biology.

[6]  D. Robertson,et al.  Total hip prosthesis metal-artifact suppression using iterative deblurring reconstruction. , 1997, Journal of computer assisted tomography.

[7]  Willi A. Kalender,et al.  Algorithms for the reduction of CT artifacts caused by metallic implants , 1990, Medical Imaging.

[8]  Luc Beaulieu,et al.  Correction of CT artifacts and its influence on Monte Carlo dose calculations. , 2007, Medical physics.

[9]  Peter Aundal Toft,et al.  A very fast implementation of 2D iterative reconstruction algorithms , 1996, 1996 IEEE Nuclear Science Symposium. Conference Record.

[10]  Wang,et al.  Iterative X-ray Cone-Beam Tomography for Metal Artifact Reduction and Local Region Reconstruction , 1999, Microscopy and Microanalysis.

[11]  Joseph A. O'Sullivan,et al.  Iterative deblurring for CT metal artifact reduction , 1996, IEEE Trans. Medical Imaging.

[12]  Mohammed Ghanbari,et al.  Scope of validity of PSNR in image/video quality assessment , 2008 .

[13]  David Faul,et al.  Suppression of Metal Artifacts in CT Using a Reconstruction Procedure That Combines MAP and Projection Completion , 2009, IEEE Transactions on Medical Imaging.