Fabrication of a thin-film capacitive force sensor array for tactile feedback in robotic surgery

Although surgical robotic systems provide several advantages over conventional minimally invasive techniques, they are limited by a lack of tactile feedback. Recent research efforts have successfully integrated tactile feedback components onto surgical robotic systems, and have shown significant improvement to surgical control during in vitro experiments. The primary barrier to the adoption of tactile feedback in clinical use is the unavailability of suitable force sensing technologies. This paper describes the design and fabrication of a thin-film capacitive force sensor array that is intended for integration with tactile feedback systems. This capacitive force sensing technology could provide precise, high-sensitivity, real-time responses to both static and dynamic loads. Capacitive force sensors were designed to operate with optimal sensitivity and dynamic range in the range of forces typical in minimally invasive surgery (0 - 40 N). Initial results validate the fabrication of these capacitive force-sensing arrays. We report 16.3 pF and 146 pF for 1-mm2 and 9-mm2 capacitive areas, respectively, whose values are within 3% of theoretical predictions.

[1]  U. Voges,et al.  Robotics and allied technologies in endoscopic surgery. , 1998, Surgical technology international.

[2]  Warren S. Grundfest,et al.  A tactile feedback system for robotic surgery , 2008, 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[3]  Miguel L Franco,et al.  An integrated pneumatic tactile feedback actuator array for robotic surgery , 2009, The international journal of medical robotics + computer assisted surgery : MRCAS.

[4]  Marc O Schurr,et al.  Artificial tactile sensing in minimally invasive surgery – a new technical approach , 2006, Minimally invasive therapy & allied technologies : MITAT : official journal of the Society for Minimally Invasive Therapy.

[5]  Marc O Schurr,et al.  Review on aspects of artificial tactile feedback in laparoscopic surgery. , 2009, Medical engineering & physics.

[6]  V. Maheshwari,et al.  Tactile devices to sense touch on a par with a human finger. , 2008, Angewandte Chemie.

[7]  Catherine E. Lewis,et al.  Tactile Feedback Induces Reduced Grasping Force in Robot-Assisted Surgery , 2009, IEEE Transactions on Haptics.

[8]  R. Ramadoss,et al.  MEMS capacitive pressure sensor array fabricated using printed circuit processing techniques , 2005, 31st Annual Conference of IEEE Industrial Electronics Society, 2005. IECON 2005..

[9]  Mark H. Lee,et al.  A Survey of Robot Tactile Sensing Technology , 1989, Int. J. Robotics Res..

[10]  Veronica J. Santos,et al.  Biomimetic Tactile Sensor Array , 2008, Adv. Robotics.

[11]  Javad Dargahi,et al.  Artificial Tactile Sensing in Biomedical Engineering , 2009 .

[12]  Blake Hannaford,et al.  Quantifying surgeon grasping mechanics in laparoscopy using the Blue DRAGON system. , 2004, Studies in health technology and informatics.