A Novel Electroosmotic Micromixer with Asymmetric Lateral Structures and DC Electrode Arrays

We present a novel electroosmotic micromixer that consists of arrays of direct current (DC) asymmetric electrode and asymmetric lateral structures. By embedding asymmetric electrode arrays on the top and bottom walls of a rectangular microchannel appropriately, the flow perturbations and vortexes can be induced when a DC electric field is imposed. An efficient lateral structure is then sequentially combined with the rectangular microchannel, which enhances the mixing effect significantly. The effects of operational parameters such as the Reynolds number, the applied potential, and the Peclet number on the mixing performance are analyzed in detail by numerical simulations. The results indicate that an enhanced mixing performance can be achieved with low applied potential. The novel method proposed in this paper provides a simple solution for mixing in the field of micro-total-analysis systems.

[1]  Shizhi Qian,et al.  Theoretical investigation of electro-osmotic flows and chaotic stirring in rectangular cavities , 2005 .

[2]  D. Erickson,et al.  Influence of Surface Heterogeneity on Electrokinetically Driven Microfluidic Mixing , 2002 .

[3]  Shizhi Qian,et al.  A stirrer for magnetohydrodynamically controlled minute fluidic networks , 2002 .

[4]  B. Han,et al.  Numerical study on the mixing performance of a ring-type electroosmotic micromixer with different obstacle configurations. , 2012, Journal of nanoscience and nanotechnology.

[5]  Shizhi Qian,et al.  Design of microfluidic channel networks with specified output flow rates using the CFD-based optimization method , 2017 .

[6]  Zhenyu Liu,et al.  Optimization of micro Venturi diode in steady flow at low Reynolds number , 2012 .

[7]  Teng Zhou,et al.  Deformability-Based Electrokinetic Particle Separation , 2016, Micromachines.

[8]  Ziliang Cai,et al.  Chaotic mixing in microchannels via low frequency switching transverse electroosmotic flow generated on integrated microelectrodes. , 2010, Lab on a chip.

[9]  J. Petersson,et al.  Topology optimization of fluids in Stokes flow , 2003 .

[10]  O. Sigmund,et al.  Topology optimization of channel flow problems , 2005 .

[11]  J. Santiago,et al.  Electrokinetic instability micromixing. , 2001, Analytical chemistry.

[12]  Nam-Trung Nguyen,et al.  Micromixers?a review , 2005 .

[13]  Teng Zhou,et al.  An Enhanced Electroosmotic Micromixer with an Efficient Asymmetric Lateral Structure , 2016, Micromachines.

[14]  Yi-Cheng Huang,et al.  Passive mixing in micro-channels with geometric variations through µPIV and µLIF measurements , 2008 .

[15]  Sangmo Kang,et al.  A Review on Mixing in Microfluidics , 2010, Micromachines.

[16]  Shizhi Qian,et al.  Optimal Control-Based Inverse Determination of Electrode Distribution for Electroosmotic Micromixer , 2016, Micromachines.

[17]  Ping Zhang,et al.  Optimization of unsteady incompressible Navier–Stokes flows using variational level set method , 2013 .

[18]  Shizhi Qian,et al.  A chaotic electroosmotic stirrer. , 2002, Analytical chemistry.

[19]  Liandong Yu,et al.  Electric field-induced instabilities in ferrofluid microflows , 2015 .

[20]  Lung-Ming Fu,et al.  Passive mixers in microfluidic systems: A review , 2016 .

[21]  Zhenyu Liu,et al.  Topology optimization of steady and unsteady incompressible Navier–Stokes flows driven by body forces , 2013 .

[22]  Shizhi Qian,et al.  Magnetohydrodynamic flow of RedOx electrolyte , 2005 .

[23]  Sungyoung Choi,et al.  Rapid laminating mixer using a contraction-expansion array microchannel , 2009 .

[24]  Nadine Aubry,et al.  Enhancement of microfluidic mixing using time pulsing. , 2003, Lab on a chip.

[25]  Zhenyu Liu,et al.  An Enhanced One-Layer Passive Microfluidic Mixer With an Optimized Lateral Structure With the Dean Effect , 2015 .

[26]  A. Nejat,et al.  Numerical study of mixing and heat transfer in mixed electroosmotic/pressure driven flow through T-shaped microchannels , 2014 .

[27]  Zhenyu Liu,et al.  Topology optimization of steady Navier–Stokes flow with body force , 2013 .

[28]  Xueye Chen,et al.  A novel design for passive misscromixers based on topology optimization method , 2016, Biomedical microdevices.

[29]  L. Fu,et al.  Microfluidic Mixing: A Review , 2011, International journal of molecular sciences.

[30]  Carl D. Meinhart,et al.  Numerical Simulation of an Electroosmotic Micromixer , 2003 .

[31]  T. Johnson,et al.  Rapid microfluidic mixing. , 2002, Analytical chemistry.

[32]  Dongqing Li,et al.  Analysis of electrokinetic flow in microfluidic networks , 2004 .

[33]  Chun Yang,et al.  Mixing enhancement in microfluidic channel with a constriction under periodic electro-osmotic flow. , 2010, Biomicrofluidics.

[34]  Ping Zhang,et al.  A flexible layout design method for passive micromixers , 2012, Biomedical Microdevices.

[35]  Kevin Ward,et al.  Mixing in microfluidic devices and enhancement methods , 2015, Journal of micromechanics and microengineering : structures, devices, and systems.

[36]  Shizhi Qian,et al.  Magneto-Hydrodynamics Based Microfluidics. , 2009, Mechanics research communications.

[37]  S. Jacobson,et al.  Microfluidic devices for electrokinetically driven parallel and serial mixing , 1999 .

[38]  Hyung Jin Sung,et al.  Pumping and mixing in a microchannel using AC asymmetric electrode arrays , 2008 .

[39]  M. Bendsøe,et al.  Generating optimal topologies in structural design using a homogenization method , 1988 .

[40]  H. Mao,et al.  A microfluidic device with a linear temperature gradient for parallel and combinatorial measurements. , 2002, Journal of the American Chemical Society.

[41]  Z. Yang,et al.  Ultrasonic micromixer for microfluidic systems , 2000, Proceedings IEEE Thirteenth Annual International Conference on Micro Electro Mechanical Systems (Cat. No.00CH36308).

[42]  Robin H. Liu,et al.  Passive mixing in a three-dimensional serpentine microchannel , 2000, Journal of Microelectromechanical Systems.

[43]  Dongqing Li,et al.  Micromixing using induced-charge electrokinetic flow , 2008 .

[44]  I. Mezić,et al.  Chaotic Mixer for Microchannels , 2002, Science.

[45]  Dongqing Li,et al.  Numerical study of a novel induced-charge electrokinetic micro-mixer. , 2013, Analytica chimica acta.

[46]  David Erickson,et al.  Heterogeneous surface charge enhanced micromixing for electrokinetic flows. , 2004, Analytical chemistry.

[47]  Zhenyu Liu,et al.  Hydrodynamic particle focusing design using fluid-particle interaction. , 2013, Biomicrofluidics.

[48]  L. H. Olesen,et al.  A high‐level programming‐language implementation of topology optimization applied to steady‐state Navier–Stokes flow , 2004, physics/0410086.

[49]  A. West,et al.  Electrokinetic flow control for composition modulation in a microchannel , 2002 .

[50]  Ping Zhang,et al.  Topology optimization of fluid channels with flow rate equality constraints , 2011 .

[51]  Ping Zhang,et al.  Topology optimization of unsteady incompressible Navier-Stokes flows , 2011, J. Comput. Phys..

[52]  O. Velev,et al.  Remotely powered distributed microfluidic pumps and mixers based on miniature diodes. , 2008, Lab on a chip.