Modes of wear after semiconstrained total elbow arthroplasty.

BACKGROUND Osteolysis and aseptic loosening are increasingly recognized complications of total elbow arthroplasty. However, unlike the literature on total hip and knee arthroplasty, studies describing the mechanisms of these processes after total elbow arthroplasty are sparse. METHODS Semiconstrained total elbow arthroplasty components were retrieved from sixteen elbows (fourteen patients) at either revision surgery (at a mean of five years after implantation) for mechanical failure (fifteen elbows) or postmortem examination (one elbow). In all cases, the retrieved implant was the primary implant. The patterns of damage on these components were investigated with stereomicroscopy in correlation with clinical findings, serial radiographs, and histopathological observations. RESULTS All of the retrieved devices exhibited multiple modes of wear. Damage to the humeral and ulnar polyethylene bushings was nearly universal; twenty-seven of twenty-eight humeral bushings demonstrated asymmetrical thinning, while fifteen of sixteen ulnar bushings demonstrated elliptical plastic deformation. In addition, unintended metal-on-metal wear between bearing and nonbearing surfaces or between two nonbearing surfaces was commonly observed, typically in association with wear and deformation of the polyethylene bushings. Wear between the stem and the cement mantle was observed in most of the ulnar components. The histopathology of the periprosthetic tissues was similar in character to that observed in association with osteolysis and loosening of total hip and knee replacements, while analysis of the particulate debris revealed a preponderance of titanium alloy and polyethylene debris. Barium sulfate particles were also observed to a lesser extent. CONCLUSIONS Multimodal wear in total elbow replacements can lead to osteolysis, aseptic loosening, and prosthetic and periprosthetic fracture necessitating revision surgery. Polyethylene wear and damage, as well as unintended metal-on-metal wear, contribute to the periprosthetic particulate burden, which is likely pathogenic in these processes.

[1]  Gandikota Girish,et al.  The adult hip , 2008 .

[2]  B. Morrey,et al.  Revision total elbow arthroplasty for prosthetic fractures. , 2006, The Journal of bone and joint surgery. American volume.

[3]  W. Mallon,et al.  Total elbow arthroplasty with the Coonrad/Coonrad-Morrey prosthesis. A 10- to 31-year survival analysis. , 2006, The Journal of bone and joint surgery. British volume.

[4]  J. Lipman,et al.  Locking mechanism failure in semiconstrained total elbow arthroplasty. , 2006, Journal of shoulder and elbow surgery.

[5]  H. Rubash,et al.  Joint Replacement and Bone Resorption: Pathology, Biomaterials and Clinical Practice , 2005 .

[6]  A. Carr,et al.  Outcomes of total elbow arthroplasty for rheumatoid arthritis: comparative study of three implants. , 2005, The Journal of bone and joint surgery. American volume.

[7]  Joshua J. Jacobs,et al.  The UHMWPE Handbook. Ultra-High Molecular Weight Polyethylene in Total Joint Replacement , 2005 .

[8]  B. Morrey,et al.  Polyethylene wear after total elbow arthroplasty. , 2005, The Journal of bone and joint surgery. American volume.

[9]  Ronald B Geskus,et al.  Limited influence of prosthetic position on aseptic loosening of elbow replacements , 2005, Acta orthopaedica.

[10]  J. Fisher Wear of Joint Replacements , 2005 .

[11]  T. Wright,et al.  Total elbow arthroplasty failure due to overuse, C-ring failure, and/or bushing wear. , 2005, Journal of shoulder and elbow surgery.

[12]  Joshua J Jacobs,et al.  Accumulation in liver and spleen of metal particles generated at nonbearing surfaces in hip arthroplasty. , 2004, The Journal of arthroplasty.

[13]  H. Hastings Minimally Constrained Elbow Implant Arthroplasty: The Discovery Elbow System , 2004, Techniques in hand & upper extremity surgery.

[14]  H. Hastings,et al.  Total elbow replacement for distal humerus fractures and traumatic deformity: results and complications of semiconstrained implants and design rationale for the Discovery Elbow System. , 2003, American journal of orthopedics.

[15]  M. Steinberg,et al.  Early Failure of Precoated Femoral Components in Primary Total Hip Arthroplasty , 2002, The Journal of bone and joint surgery. American volume.

[16]  R. Coutts,et al.  Early failure of a roughened surface, precoated femoral component in total hip arthroplasty. , 2001, The Journal of arthroplasty.

[17]  J. Stanley,et al.  The effect of epidemiologic and intraoperative factors on survival of the standard Souter-Strathclyde total elbow arthroplasty. , 2000, The Journal of arthroplasty.

[18]  T. Wright,et al.  Functional outcome comparison of semiconstrained and unconstrained total elbow arthroplasties. , 2000, Journal of shoulder and elbow surgery.

[19]  J. Macdermid,et al.  Functional Outcome of Semiconstrained Total Elbow Arthroplasty* , 2000, The Journal of bone and joint surgery. American volume.

[20]  P Mansat,et al.  Semiconstrained Total Elbow Arthroplasty for Ankylosed and Stiff Elbows* , 2000, The Journal of bone and joint surgery. American volume.

[21]  B. Moretti,et al.  Hydroxyapatite coated with hepatocyte growth factor (HGF) stimulates human osteoblasts in vitro , 2000 .

[22]  M. Péoc'h,et al.  Dissemination of Wear Particles to the Liver, Spleen, and Abdominal Lymph Nodes of Patients with Hip or Knee Replacement* , 2000, The Journal of bone and joint surgery. American volume.

[23]  D. Ferlic Total elbow arthroplasty for treatment of elbow arthritis. , 1999, Journal of shoulder and elbow surgery.

[24]  T. Bauer,et al.  Relationship between wear debris particles and polyethylene surface damage in primary total knee arthroplasty. , 1999, The Journal of arthroplasty.

[25]  B F Morrey,et al.  Total elbow arthroplasty in primary osteoarthritis of the elbow. , 1998, The Journal of arthroplasty.

[26]  B F Morrey,et al.  The Coonrad-Morrey Total Elbow Arthroplasty in Patients Who Have Rheumatoid Arthritis. A Ten to Fifteen-Year Follow-up Study* , 1998, The Journal of bone and joint surgery. American volume.

[27]  B. Morrey,et al.  Semiconstrained Total Elbow Replacement for the Treatment of Post-Traumatic Osteoarthrosis* , 1997, The Journal of bone and joint surgery. American volume.

[28]  B. Morrey,et al.  Total Elbow Arthroplasty as Primary Treatment for Distal Humeral Fractures in Elderly Patients* , 1997, The Journal of bone and joint surgery. American volume.

[29]  F. Risung The Norway Elbow Replacement: Design, Technique And Results After Nine Years , 1997 .

[30]  B. Morrey,et al.  Total Elbow Arthroplasty: Revision with Use of a Non-Custom Semiconstrained Prosthesis* , 1997, The Journal of bone and joint surgery. American volume.

[31]  A. Inglis,et al.  Total elbow arthroplasty for flail and unstable elbows. , 1996, Journal of shoulder and elbow surgery.

[32]  B F Morrey,et al.  Loose-hinge total elbow arthroplasty. An experimental study of the effects of implant alignment on three-dimensional elbow kinematics. , 1995, The Journal of arthroplasty.

[33]  J. Galante,et al.  Human monocyte response to particulate biomaterials generated in vivo and in vitro , 1995, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[34]  M. McKee,et al.  Semiconstrained elbow replacement for distal humeral nonunion. , 1995, The Journal of bone and joint surgery. British volume.

[35]  C. Ranawat,et al.  Primary semiconstrained total elbow arthroplasty. Survival analysis of 113 consecutive cases. , 1994, The Journal of bone and joint surgery. British volume.

[36]  B. Morrey,et al.  Semiconstrained arthroplasty for the treatment of rheumatoid arthritis of the elbow. , 1992, The Journal of bone and joint surgery. American volume.

[37]  B. Morrey,et al.  Total replacement for post-traumatic arthritis of the elbow. , 1991, The Journal of bone and joint surgery. British volume.

[38]  C. Laurencin,et al.  Sciatic-nerve palsy associated with a retained plastic shot container in a shotgun injury. A case report. , 1991, The Journal of bone and joint surgery. American volume.

[39]  A. Inglis,et al.  Total elbow arthroplasty for complete ankylosis of the elbow. , 1989, The Journal of bone and joint surgery. American volume.

[40]  A. Inglis,et al.  A critical analysis of alignment factors affecting functional outcome in total elbow arthroplasty. , 1986, The Journal of arthroplasty.

[41]  R. L. Linscheid,et al.  Total elbow arthroplasty. A five-year experience at the Mayo Clinic. , 1981, The Journal of bone and joint surgery. American volume.

[42]  H. Amstutz,et al.  "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening. , 1979, Clinical orthopaedics and related research.