Magnetoacoustic imaging of human liver tumor with magnetic induction.

Magnetoacoustic tomography with magnetic induction (MAT-MI) is an imaging technique under development to achieve imaging of electrical impedance contrast in biological tissues with spatial resolution close to ultrasound imaging. However, previously reported MAT-MI experimental results are obtained either from low salinity gel phantoms, or from normal animal tissue samples. In this study, we report the experimental study on the performance of the MAT-MI imaging method for imaging in vitro human liver tumor tissue. The present promising experimental results suggest the feasibility of MAT-MI to image electrical impedance contrast between the cancerous tissue and its surrounding normal tissues.

[1]  Qingyu Ma,et al.  Magnetoacoustic Tomography With Magnetic Induction: A Rigorous Theory , 2008, IEEE Transactions on Biomedical Engineering.

[2]  M.R. Islam,et al.  A magneto-acoustic method for the noninvasive measurement of bioelectric currents , 1988, IEEE Transactions on Biomedical Engineering.

[3]  M. Joy,et al.  In vivo detection of applied electric currents by magnetic resonance imaging. , 1989, Magnetic resonance imaging.

[4]  Xu Li,et al.  Multi-excitation Magnetoacoustic Tomography With Magnetic Induction for Bioimpedance Imaging , 2010, IEEE Transactions on Medical Imaging.

[5]  Bin He,et al.  Magnetoacoustic tomography with magnetic induction (MAT-MI) , 2005, Physics in medicine and biology.

[6]  Lihong V. Wang,et al.  Time reversal and its application to tomography with diffracting sources. , 2004, Physical review letters.

[7]  Hong Cao,et al.  In-vivo measurement of swine myocardial resistivity , 2002, IEEE Transactions on Biomedical Engineering.

[8]  Bin He,et al.  Imaging biological tissues with electrical conductivity contrast below 1 S m by means of magnetoacoustic tomography with magnetic induction. , 2010, Applied physics letters.

[9]  Ohin Kwon,et al.  Magnetic resonance electrical impedance tomography (MREIT): simulation study of J-substitution algorithm , 2002, IEEE Transactions on Biomedical Engineering.

[10]  Bin He,et al.  Magnetoacoustic tomography with magnetic induction for imaging electrical impedance of biological tissue , 2006 .

[11]  Bin He,et al.  Magnetoacoustic tomographic imaging of electrical impedance with magnetic induction. , 2007, Applied physics letters.

[12]  Joaquim Ferreira,et al.  An overview of electromagnetic inductance tomography: Description of three different systems , 1996 .

[13]  B.A. Baertlein,et al.  Authors' reply [to comments on "Theoretical model for an MRI radio frequency resonator"] , 1994, IEEE Transactions on Biomedical Engineering.

[14]  Kevin Paulson,et al.  Optimal experiments in electrical impedance tomography , 1993, IEEE Trans. Medical Imaging.

[15]  Xu Li,et al.  Imaging Electrical Impedance From Acoustic Measurements by Means of Magnetoacoustic Tomography With Magnetic Induction (MAT-MI) , 2007, IEEE Transactions on Biomedical Engineering.

[16]  J. Shah,et al.  Hall effect imaging , 1998, IEEE Transactions on Biomedical Engineering.