Single-phase 50-kW 16.7-Hz PI-controlled four-quadrant line-side converter lab model fed by rotary converter

Four-quadrant line-side converters supplying PWM-inverter-fed induction machines are a standard application in railway traction vehicles. In scope of an extensive project aiming at an advanced overall control scheme for traction vehicles taking amongst others grid interaction and stability into account, the steady-state and transient operation of a single-phase 50-kW, 16.7-Hz four-quadrant line-side converter are analysed in detail. This topology is hereby fed by a slip-ring induction generator (IG) with DC excitation, operating as railway-grid rotary-converter representation. In this paper the structure of the 50-kW test bench representing a railway grid and a traction vehicle and the used PC-based real-time control hardware are introduced. Despite the highly disturbed rotary converter output voltage measurement results verifying excellent operation are given for the line-side converter, whose PI-control scheme is described in detail. Hereby two different loads are used: resistor and motor inverter.

[1]  V. Staudt,et al.  Approximation of transient torque response of a traction drive controlled by Indirect Stator-Quantities Control (ISC) , 2009, 2009 Compatibility and Power Electronics.

[2]  V. Staudt,et al.  Single-phase 50-kW, 16.7-Hz railway-grid representation featuring variable grid parameters , 2008, 2008 IEEE Power Electronics Specialists Conference.

[3]  V. Staudt,et al.  Implications of resonant circuit adjustment errors to the DC-link voltage in single-phase 16.7-Hz-railway applications , 2009, 2009 Compatibility and Power Electronics.

[4]  V. Staudt,et al.  LQ-optimized multivariable control for a single-phase 50-kW, 16.7-Hz railway-grid representation featuring variable grid parameters , 2009, 2009 Compatibility and Power Electronics.

[5]  V. Staudt,et al.  Single-phase 50-kW, 16.7-Hz railway-grid Lab Representation using a DC-excited slip-ring induction generator , 2009, 2009 Compatibility and Power Electronics.

[6]  V. Staudt,et al.  PLL and DFT feed-forward control for railway single-phase line-converter synchronisation , 2009, 2009 Compatibility and Power Electronics.

[7]  V. Staudt,et al.  Multivariable pole-placement control design for a single-phase 50-kW, 16.7-Hz railway traction line-side converter , 2009, 2009 International Conference on Power Engineering, Energy and Electrical Drives.

[8]  V. Staudt,et al.  Dead-beat control for a single-phase 50-kW, 16.7-Hz railway-grid representation inverter featuring variable grid parameters , 2009, 2009 International Conference on Power Engineering, Energy and Electrical Drives.

[9]  V. Staudt,et al.  Single-phase 50-kW 16.7-Hz four-quadrant line-side converter for railway traction application , 2008, 2008 13th International Power Electronics and Motion Control Conference.