Basic considerations on the impact of the coil array on the performance of Transmit SENSE

Abstract“Transmit SENSE” adapts the idea of parallel imaging to RF transmission. Using multiple independent transmit coils, the duration of a spatially selective RF pulse can be reduced. It is known from parallel imaging that a suboptimal coil-array geometry might lead to an ill-conditioned sensitivity matrix and, thus, to a non-homogenous noise amplification in the resulting image. The current paper investigates the consequences of suboptimal coil arrays for Transmit SENSE. Two possible consequences of a suboptimal coil array are studied in the framework of numerical simulations: the incorrect excitation of the desired spatial pattern and the increase of the specific energy absorption rate (SAR), i.e. the RF power required to excite the desired pattern. Incorrect pattern excitation occurs only in pathologic coil-array scenarios. The increase of the SAR is very moderate for a large range of coil-array geometries. Using spiral excitation k-space trajectories leads to superior results compared to Cartesian trajectories. The problem of an ill-conditioned matrix inversion does not seem to play a major role in Transmit SENSE. Consequently, the freedom in designing coil arrays seems to be much larger in Transmit SENSE than in SENSE in the receive mode.

[1]  Jennifer Keegan,et al.  Three‐dimensional coronary MR angiography using zonal echo planar imaging , 1998, Magnetic resonance in medicine.

[2]  Todd S. Sachs,et al.  Real‐time motion detection in spiral MRI using navigators , 1994, Magnetic resonance in medicine.

[3]  Bob S. Hu,et al.  A three‐dimensional spin‐echo or inversion pulse , 1993, Magnetic resonance in medicine.

[4]  Peter Börnert,et al.  Theoretical and numerical aspects of transmit SENSE , 2004, IEEE Transactions on Medical Imaging.

[5]  Christopher J. Hardy,et al.  Broadband nuclear magnetic resonance pulses with two‐dimensional spatial selectivity , 1989 .

[6]  P Börnert,et al.  Curved slice imaging , 1996, Magnetic resonance in medicine.

[7]  Christopher J. Hardy,et al.  Spatial localization in two dimensions using NMR designer pulses , 1989 .

[8]  P. Börnert,et al.  Transmit SENSE , 2003, Magnetic resonance in medicine.

[9]  Albert Macovski,et al.  A linear class of large-tip-angle selective excitation pulses , 1989 .

[10]  F. Liu,et al.  Electromagnetic fields inside a lossy, multilayered spherical head phantom excited by MRI coils: models and methods. , 2004, Physics in medicine and biology.

[11]  Ray F. Lee,et al.  Coupling and decoupling theory and its application to the MRI phased array , 2002, Magnetic resonance in medicine.

[12]  Yudong Zhu,et al.  Parallel excitation with an array of transmit coils , 2004, Magnetic resonance in medicine.

[13]  P. Boesiger,et al.  SENSE: Sensitivity encoding for fast MRI , 1999, Magnetic resonance in medicine.

[14]  D. Hoult,et al.  The NMR multi-transmit phased array: a Cartesian feedback approach. , 2004, Journal of magnetic resonance.

[15]  M. T. Vlaardingerbroek,et al.  Magnetic Resonance Imaging: Theory and Practice , 1996 .

[16]  A Macovski,et al.  A reduced power selective adiabatic spin‐echo pulse sequence , 1991, Magnetic resonance in medicine.