Distal radius volar rim plate: Technical and radiographic considerations

AIM To determine technical considerations and radiographic outcomes of the Synthes volar rim distal radius plate to treat complex intra-articular fractures. METHODS This review highlights technical considerations learnt using this implant since it was introduced in a major trauma unit in November 2011, including anatomical reduction and whether this was maintained radiographically. RESULTS Twenty-six of the 382 internally fixed distal radial fractures at our unit (6.8%) were deemed to require this plate in order to achieve optimal fracture fixation between November 2011 and May 2014. A further dorsal and/or radial plate was necessary in 35% and variable angle screws were used in 54% of cases. Post-operatively, mean radial height, inclination, volar tilt and ulnar variance restored were 11.7 mm, 21º, 4.3º and -1.2 mm respectively. There were no cases of non-union or flexor/extensor tendon rupture; one case of loss of fracture reduction. Overall incidence of plate removal was 15% with one plate removed for flexor and one for extensor tendon irritation CONCLUSION The use of a rim plate enables control of challenging far distal fracture patterns. However, additional plates were required to improve and maintain reduction. Variable angle screws were necessary in half the cases to avoid intra-articular screw penetration. If used judiciously, this implant can achieve stable fixation despite the complexity of the fracture pattern.

[1]  M. Guzzini,et al.  Is it really necessary to restore radial anatomic parameters after distal radius fractures , 2014 .

[2]  D. Power,et al.  Response to: Beware the volar ulnar fragment in a comminuted Bartons fracture. , 2014, Hand surgery : an international journal devoted to hand and upper limb surgery and related research : journal of the Asia-Pacific Federation of Societies for Surgery of the Hand.

[3]  G. Marco,et al.  Is it really necessary to restore radial anatomic parameters after distal radius fractures? , 2014, Injury.

[4]  W. Chew,et al.  Beware! The volar ulnar fragment in a comminuted Bartons fracture. , 2013, Hand surgery : an international journal devoted to hand and upper limb surgery and related research : journal of the Asia-Pacific Federation of Societies for Surgery of the Hand.

[5]  A. Weiland,et al.  Volar plate position and flexor tendon rupture following distal radius fracture fixation. , 2013, The Journal of hand surgery.

[6]  C. Charalambous,et al.  Reoperation for metalwork complications following the use of volar locking plates for distal radius fractures: a United Kingdom experience. , 2011, Hand surgery : an international journal devoted to hand and upper limb surgery and related research : journal of the Asia-Pacific Federation of Societies for Surgery of the Hand.

[7]  P. Blazar,et al.  Volar locking plate implant prominence and flexor tendon rupture. , 2011, The Journal of bone and joint surgery. American volume.

[8]  P. Rommens,et al.  Number and locations of screw fixation for volar fixed-angle plating of distal radius fractures: biomechanical study. , 2010, The Journal of hand surgery.

[9]  D. Hanel,et al.  Complications associated with distraction plate fixation of wrist fractures. , 2010, Hand clinics.

[10]  Rohit Arora,et al.  Complications Following Internal Fixation of Unstable Distal Radius Fracture With a Palmar Locking-Plate , 2007, Journal of orthopaedic trauma.

[11]  D. Hanel,et al.  Bridge Plating of Distal Radius Fractures: The Harborview Method , 2006, Clinical orthopaedics and related research.

[12]  A. Touhami,et al.  Current concepts in volar fixed-angle fixation of unstable distal radius fractures. , 2006, Clinical orthopaedics and related research.

[13]  R. Idler,et al.  Volar fixation of dorsally displaced distal radius fractures using the 2.4-mm locking compression plates. , 2005, The Journal of hand surgery.

[14]  D. Ring,et al.  Prospective multicenter trial of a plate for dorsal fixation of distal radius fractures. , 1997, The Journal of hand surgery.