Small animal radiotherapy research platforms

Advances in conformal radiation therapy and advancements in pre-clinical radiotherapy research have recently stimulated the development of precise micro-irradiators for small animals such as mice and rats. These devices are often kilovolt x-ray radiation sources combined with high-resolution CT imaging equipment for image guidance, as the latter allows precise and accurate beam positioning. This is similar to modern human radiotherapy practice. These devices are considered a major step forward compared to the current standard of animal experimentation in cancer radiobiology research. The availability of this novel equipment enables a wide variety of pre-clinical experiments on the synergy of radiation with other therapies, complex radiation schemes, sub-target boost studies, hypofractionated radiotherapy, contrast-enhanced radiotherapy and studies of relative biological effectiveness, to name just a few examples. In this review we discuss the required irradiation and imaging capabilities of small animal radiation research platforms. We describe the need for improved small animal radiotherapy research and highlight pioneering efforts, some of which led recently to commercially available prototypes. From this, it will be clear that much further development is still needed, on both the irradiation side and imaging side. We discuss at length the need for improved treatment planning tools for small animal platforms, and the current lack of a standard therein. Finally, we mention some recent experimental work using the early animal radiation research platforms, and the potential they offer for advancing radiobiology research.

[1]  Boyd McCurdy,et al.  Cone beam computerized tomography: the effect of calibration of the Hounsfield unit number to electron density on dose calculation accuracy for adaptive radiation therapy , 2009, Physics in medicine and biology.

[2]  David A Jaffray,et al.  Dosimetric variation due to the photon beam energy in the small-animal irradiation: a Monte Carlo study. , 2010, Medical physics.

[3]  Lei Xing,et al.  Evaluation of on-board kV cone beam CT (CBCT)-based dose calculation , 2007, Physics in medicine and biology.

[4]  T D Solberg,et al.  Dosimetric characterization of an image-guided stereotactic small animal irradiator , 2011, Physics in medicine and biology.

[5]  James C L Chow,et al.  Treatment planning for a small animal using Monte Carlo simulation. , 2007, Medical physics.

[6]  Joseph O Deasy,et al.  Feasibility of small animal cranial irradiation with the microRT system. , 2008, Medical physics.

[7]  T D Solberg,et al.  An x-ray image guidance system for small animal stereotactic irradiation , 2010, Physics in medicine and biology.

[8]  Clemencia Pinilla,et al.  Targeting the apoptotic machinery in pancreatic cancers using small-molecule antagonists of the X-linked inhibitor of apoptosis protein , 2007, Molecular Cancer Therapeutics.

[9]  F Verhaegen,et al.  A comprehensive system for dosimetric commissioning and Monte Carlo validation for the small animal radiation research platform , 2009, Physics in medicine and biology.

[10]  J. Wong,et al.  Flat-panel cone-beam computed tomography for image-guided radiation therapy. , 2002, International journal of radiation oncology, biology, physics.

[11]  Andries G Visser,et al.  Bath and shower effect in spinal cord: the effect of time interval. , 2009, International journal of radiation oncology, biology, physics.

[12]  Carmel Mothersill,et al.  Radiation-Induced Bystander Effects: Past History and Future Directions , 2001, Radiation research.

[13]  C. Ma,et al.  BEAM: a Monte Carlo code to simulate radiotherapy treatment units. , 1995, Medical physics.

[14]  Marc S. Mendonca,et al.  Use of the Leksell Gamma Knife for Localized Small Field Lens Irradiation in Rodents , 2003, Technology in cancer research & treatment.

[15]  Frank Verhaegen,et al.  Dosimetric consequences of misalignment and realignment in prostate 3DCRT using intramodality ultrasound image guidance. , 2010, Medical physics.

[16]  Joseph M Kaminski,et al.  The controversial abscopal effect. , 2005, Cancer treatment reviews.

[17]  Peter Kazanzides,et al.  High-resolution, small animal radiation research platform with x-ray tomographic guidance capabilities. , 2008, International journal of radiation oncology, biology, physics.

[18]  R. Sievert,et al.  Book Reviews : Recommendations of the International Commission on Radiological Protection (as amended 1959 and revised 1962). I.C.R.P. Publication 6. 70 pp. PERGAMON PRESS. Oxford, London and New York, 1964. £1 5s. 0d. [TB/54] , 1964 .

[19]  Timothy D Solberg,et al.  An Orthotopic Lung Tumor Model for Image-Guided Microirradiation in Rats , 2010, Radiation research.

[20]  R Peng,et al.  A dynamic micro-CT scanner based on a carbon nanotube field emission x-ray source , 2009, Physics in medicine and biology.

[21]  I. Kawrakow Accurate condensed history Monte Carlo simulation of electron transport. I. EGSnrc, the new EGS4 version. , 2000, Medical physics.

[22]  Peter Kazanzides,et al.  Image-guided small animal radiation research platform: calibration of treatment beam alignment , 2009, Physics in medicine and biology.

[23]  Salomeh Jelveh,et al.  Gold Nanoparticles as Radiation Sensitizers in Cancer Therapy , 2010, Radiation research.

[24]  James C. L. Chow,et al.  Depth dose dependence of the mouse bone using kilovoltage photon beams: A Monte Carlo study for small-animal irradiation , 2010 .

[25]  Parag J. Parikh,et al.  TU‐C‐BRD‐06: Preclinical Image Guided Microirradiators: Concepts, Design and Implementation , 2009 .

[26]  Steven K Boyd,et al.  Radiation effects on bone architecture in mice and rats resulting from in vivo micro-computed tomography scanning. , 2008, Medical engineering & physics.

[27]  B. G. Szabó,et al.  Comparison of three rat strains for development of radiation-induced lung injury after hemithoracic irradiation. , 2001, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[28]  P Keall,et al.  An analytical model of a kilovoltage beam phase space. , 1999, Medical physics.

[29]  A. Balmain,et al.  Guidelines for the welfare and use of animals in cancer research , 2010, British Journal of Cancer.

[30]  Joseph O Deasy,et al.  CERR: a computational environment for radiotherapy research. , 2003, Medical physics.

[31]  R Fahrig,et al.  Three-dimensional computed tomographic reconstruction using a C-arm mounted XRII: correction of image intensifier distortion. , 1997, Medical physics.

[32]  Paul J Keall,et al.  Investigation of the effects of treatment planning variables in small animal radiotherapy dose distributions. , 2010, Medical physics.

[33]  Sasa Mutic,et al.  Progress toward a microradiation therapy small animal conformal irradiator. , 2006, Medical physics.

[34]  Imants Svalbe,et al.  Tumor cell response to synchrotron microbeam radiation therapy differs markedly from cells in normal tissues. , 2010, International journal of radiation oncology, biology, physics.

[35]  W. Enghardt,et al.  Tumour bed irradiation of human tumour xenografts in a nude rat model using a common X-ray tube , 2010, Journal of Biosciences.

[36]  María-Ester Brandan,et al.  Use of an orthovoltage X-ray treatment unit as a radiation research system in a small-animal cancer model , 2008, Journal of experimental & clinical cancer research : CR.

[37]  Eduardo G Moros,et al.  Evaluation of spatially fractionated radiotherapy (GRID) and definitive chemoradiotherapy with curative intent for locally advanced squamous cell carcinoma of the head and neck: initial response rates and toxicity. , 2010, International journal of radiation oncology, biology, physics.

[38]  David A Jaffray,et al.  Cellular uptake and transport of gold nanoparticles incorporated in a liposomal carrier. , 2010, Nanomedicine : nanotechnology, biology, and medicine.

[39]  Søren M Bentzen,et al.  Randomized controlled trials in health technology assessment: overkill or overdue? , 2008, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[40]  Frank Verhaegen,et al.  Patient-specific dosimetry of conventional and intensity modulated radiation therapy using a novel full Monte Carlo phase space reconstruction method from electronic portal images , 2007, Physics in medicine and biology.

[41]  Vitali Moiseenko,et al.  In vitro study of cell survival following dynamic MLC intensity-modulated radiation therapy dose delivery. , 2007, Medical physics.

[42]  Robert Jeraj,et al.  Design of a radiation facility for very small specimens used in radiobiology studies , 2008, Physics in medicine and biology.

[43]  Erik Tryggestad,et al.  Differentiation between glioma and radiation necrosis using molecular magnetic resonance imaging of endogenous proteins and peptides , 2010, Nature Medicine.

[44]  Jaeho Cho,et al.  High dose-per-fraction irradiation of limited lung volumes using an image-guided, highly focused irradiator: simulating stereotactic body radiotherapy regimens in a small-animal model. , 2010, International journal of radiation oncology, biology, physics.

[45]  F. Verhaegen,et al.  Dual-energy CT-based material extraction for tissue segmentation in Monte Carlo dose calculations , 2008, Physics in medicine and biology.

[46]  D. Jaffray,et al.  A ghost story: spatio-temporal response characteristics of an indirect-detection flat-panel imager. , 1999, Medical physics.

[47]  S Mutic,et al.  MicroRT-small animal conformal irradiator. , 2007, Medical physics.

[48]  Paul J Keall,et al.  A bone composition model for Monte Carlo x-ray transport simulations. , 2009, Medical physics.

[49]  G. Johnson,et al.  In vivo small-animal imaging using micro-CT and digital subtraction angiography , 2008, Physics in medicine and biology.

[50]  Paul J Keall,et al.  Development of a micro-computed tomography-based image-guided conformal radiotherapy system for small animals. , 2010, International journal of radiation oncology, biology, physics.

[51]  Devika B Chithrani,et al.  Nanoparticles for improved therapeutics and imaging in cancer therapy. , 2010, Recent patents on nanotechnology.

[52]  J Law The influence of focal spot size on image resolution and test phantom scores in mammography. , 1993, The British journal of radiology.

[53]  Christopher H Contag,et al.  Design and evaluation of a variable aperture collimator for conformal radiotherapy of small animals using a microCT scanner. , 2007, Medical physics.

[54]  Otto Zhou,et al.  SU‐GG‐J‐130: Recent Development of a Carbon Nanotube Field Emission Based X‐Ray Micro‐Radiotherapy System for Small Animal Radiotherapy , 2010 .

[55]  A. Rehemtulla,et al.  Combined radiation and enzyme/prodrug treatment for head and neck cancer in an orthotopic animal model. , 1999, Radiation research.

[56]  Frank Verhaegen,et al.  Dosimetric and microdosimetric study of contrast-enhanced radiotherapy with kilovolt x-rays , 2005, Physics in medicine and biology.

[57]  H P Beck-Bornholdt,et al.  Impact of pulmonary metastases of the R1H-tumour on radiation tolerance of rat lung , 2001, International journal of radiation biology.

[58]  R. Cloutier Tissue Substitutes in Radiation Dosimetry and Measurement. , 1989 .

[59]  Frank Verhaegen,et al.  Sensitivity of low energy brachytherapy Monte Carlo dose calculations to uncertainties in human tissue composition. , 2010, Medical physics.

[60]  R. Mole,et al.  Quantitative observations on recovery from whole body irradiation in mice. II. Recovery during and after daily irradiation. , 1957, The British journal of radiology.

[61]  Frank Verhaegen,et al.  A CT-based analytical dose calculation method for HDR 192Ir brachytherapy. , 2009, Medical physics.

[62]  Julia F. Barrett,et al.  Artifacts in CT: recognition and avoidance. , 2004, Radiographics : a review publication of the Radiological Society of North America, Inc.

[63]  C. H. Clement,et al.  The Impact of the 2007 Recommendations of the International Commission on Radiological Protection (ICRP) in Medical Applications , 2009 .

[64]  Robert Jeraj,et al.  Characterization of a novel micro-irradiator using Monte Carlo radiation transport simulations , 2008, Physics in medicine and biology.

[65]  James C.L. Chow,et al.  A graphical user interface for calculation of 3D dose distribution using Monte Carlo simulations , 2008 .

[66]  C Field,et al.  Relative biological damage and electron fluence in and out of a 6 MV photon field , 2009, Physics in medicine and biology.

[67]  D A Jaffray,et al.  Characterization of image quality and image-guidance performance of a preclinical microirradiator. , 2011, Medical physics.

[68]  John M. Boone,et al.  Optimizing the x-ray photon energy for digital radiographic imaging systems , 2002, SPIE Medical Imaging.

[69]  Paul Keall,et al.  Commissioning of a novel microCT/RT system for small animal conformal radiotherapy , 2009, Physics in medicine and biology.

[70]  R. Mohan,et al.  Converting absorbed dose to medium to absorbed dose to water for Monte Carlo based photon beam dose calculations. , 2000, Physics in medicine and biology.

[71]  E. Ritman,et al.  Molecular imaging in small animals—roles for micro‐CT , 2002, Journal of cellular biochemistry. Supplement.

[72]  Katsumi Kobayashi,et al.  Bystander Cell Death is Modified by Sites of Energy Deposition within Cells Irradiated with a Synchrotron X-Ray Microbeam , 2010, Radiation research.

[73]  Mark V. Hendricks,et al.  Radiation-induced lung injury , 1999 .

[74]  Paul J Keall,et al.  Kilovoltage beam Monte Carlo dose calculations in submillimeter voxels for small animal radiotherapy. , 2009, Medical physics.

[75]  Andries G Visser,et al.  Dose-volume effects in rat thoracolumbar spinal cord: the effects of nonuniform dose distribution. , 2007, International journal of radiation oncology, biology, physics.

[76]  William R. Brody,et al.  Digital Subtraction Angiography , 1982, IEEE Transactions on Nuclear Science.

[77]  J J Battista,et al.  Generation of photon energy deposition kernels using the EGS Monte Carlo code. , 1988, Physics in medicine and biology.

[78]  John A Kalef-Ezra,et al.  Gold nanoparticles enhance the radiation therapy of a murine squamous cell carcinoma , 2010, Physics in medicine and biology.

[79]  Russell H. Taylor,et al.  Towards real-time radiation therapy: GPU accelerated superposition/convolution , 2010, Comput. Methods Programs Biomed..

[80]  Guohua Cao,et al.  Prospective-gated cardiac micro-CT imaging of free-breathing mice using carbon nanotube field emission x-ray. , 2010, Medical physics.

[81]  C Field,et al.  A Monte Carlo study of the variation of electron fluence in water from a 6 MV photon beam outside of the field , 2007, Physics in medicine and biology.

[82]  M E Easterly,et al.  A review of high-resolution X-ray computed tomography and other imaging modalities for small animal research. , 2001, Lab animal.

[83]  Rudi Deklerck,et al.  Evaluation of the radiation dose in micro-CT with optimization of the scan protocol. , 2010, Contrast media & molecular imaging.

[84]  Andre Obenaus,et al.  Radiation dose in rodent tissues during micro-CT imaging , 2004 .

[85]  Willi A. Kalender,et al.  Computed tomography : fundamentals, system technology, image quality, applications , 2000 .

[86]  D W Holdsworth,et al.  Fundamental image quality limits for microcomputed tomography in small animals. , 2003, Medical physics.

[87]  Frank Verhaegen,et al.  Monte Carlo modelling of external radiotherapy photon beams. , 2003, Physics in medicine and biology.

[88]  Daniel A. Low,et al.  TH‐C‐204B‐10: Implementation of a Small Animal Image Guided Microirradiator: The MicroIGRT , 2010 .

[89]  M. Al-Ghazi,et al.  Experimental evaluation of interface doses in the presence of air cavities compared with treatment planning algorithms , 1999 .

[90]  F Verhaegen,et al.  Monte Carlo modelling of radiotherapy kV x-ray units. , 1999, Physics in medicine and biology.

[91]  G. Nikiforidis,et al.  In vivo small animal imaging: current status and future prospects. , 2010, Medical physics.

[92]  H Meertens,et al.  Loco-regional differences in pulmonary function and density after partial rat lung irradiation. , 2003, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[93]  Sang Hyun Cho,et al.  Estimation of microscopic dose enhancement factor around gold nanoparticles by Monte Carlo calculations. , 2010, Medical physics.

[94]  F. H. Attix Introduction to Radiological Physics and Radiation Dosimetry , 1991 .

[95]  Joseph O. Deasy,et al.  TH‐C‐230A‐08: A Prototype Rotational Immobilization System for a Proposed Static‐Gantry MicroRT Device with Tomographic Capabilities , 2006 .

[96]  Erik Tryggestad,et al.  Sertraline slows disease progression and increases neurogenesis in N171-82Q mouse model of Huntington's disease , 2008, Neurobiology of Disease.

[97]  James C L Chow,et al.  Treatment planning for a small animal using Monte Carlo simulation. , 2007, Medical physics.

[98]  Frank Verhaegen,et al.  Tissue segmentation in Monte Carlo treatment planning: a simulation study using dual-energy CT images. , 2008, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[99]  F. Khan The physics of radiation therapy , 1985 .

[100]  F Verhaegen,et al.  The effects of compensator and imaging geometry on the distribution of x-ray scatter in CBCT. , 2011, Medical physics.

[101]  T Aakhus,et al.  [Digital subtraction angiography]. , 1983, Tidsskrift for den Norske laegeforening : tidsskrift for praktisk medicin, ny raekke.

[102]  Lennart Lindborg,et al.  RBE of low energy electrons and photons , 2010, Physics in medicine and biology.

[103]  P. Lambin,et al.  A literature review of electronic portal imaging for radiotherapy dosimetry. , 2008, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[104]  Jonathan S. Maltz,et al.  Algorithm for X-ray Scatter, Beam-Hardening, and Beam Profile Correction in Diagnostic (Kilovoltage) and Treatment (Megavoltage) Cone Beam CT , 2008, IEEE Transactions on Medical Imaging.

[105]  P. Lambin,et al.  The ESTRO Breur Lecture 2009. From population to voxel-based radiotherapy: exploiting intra-tumour and intra-organ heterogeneity for advanced treatment of non-small cell lung cancer. , 2010, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[106]  Daniela Thorwarth,et al.  Physical radiotherapy treatment planning based on functional PET/CT data. , 2010, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[107]  Devika B. Chithrani,et al.  Intracellular uptake, transport, and processing of gold nanostructures , 2010, Molecular membrane biology.