Performances of heated humidifiers in mechanical ventilation: A preliminary intra-breath analysis

A correct humidification of gases delivered to mechanically ventilated patients is essential to avoid some complications. Heated Humidifiers (HHs) are widely used in long lasting ventilation to treat gases delivered to patients. Their performances depend on some parameters, such as environmental conditions and ventilatory settings. The aim of this work is to experimentally assess the influence of minute volume (MV), respiratory frequency (f) and the ratio between duration of inspiration and expiration (I:E) on HHs performances in terms of relative humidity (RH) at the humidification chamber outlet. The main novelty of this work is the assessment of RH oscillations during artificial ventilation. Results show marked oscillations of RH during a single breath (ripple of 20% in the worst case); oscillations decrease if f and I:E increase, on the other hand they increase with MV. Since the variation of gas temperature during a respiratory act can be neglected, the RH oscillations are related to the vapour content in the delivered gases. These results further support the hypothesis which asserts that HHs performances could be improved by using a control strategy taking into account ventilatory settings.

[1]  Sergio Silvestri,et al.  Gas pre-warming for improving performances of heated humidifiers in neonatal ventilation , 2011, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[2]  P. Pelosi,et al.  Performance of heated wire humidifiers: an in vitro study. , 2007, Journal of critical care.

[3]  E Schena,et al.  A novel control strategy to improve the performances of heated wire humidifiers in artificial neonatal ventilation. , 2012, Physiological measurement.

[4]  Arden L. Buck,et al.  New Equations for Computing Vapor Pressure and Enhancement Factor , 1981 .

[5]  T Mashimo,et al.  Performance of heated humidifiers with a heated wire according to ventilatory settings. , 2001, Journal of aerosol medicine : the official journal of the International Society for Aerosols in Medicine.

[6]  J. Ward,et al.  Airway humidification during high-frequency percussive ventilation. , 2009, Respiratory care.

[7]  Nigel Rankin,et al.  Energy balance in the intubated human airway is an indicator of optimal gas conditioning , 2002, Critical care medicine.

[8]  Sergio Silvestri,et al.  A transistor based air flow transducer for thermohygrometric control of neonatal ventilatory applications. , 2008, The Review of scientific instruments.

[9]  R. Branson The effects of inadequate humidity. , 1998, Respiratory care clinics of North America.

[10]  Sergio Silvestri,et al.  Mathematical model and minimal measurement system for optimal control of heated humidifiers in neonatal ventilation. , 2010, Medical engineering & physics.

[11]  D. Galler,et al.  Relationship between the humidity and temperature of inspired gas and the function of the airway mucosa. , 1996, Critical care medicine.

[12]  François Lellouche,et al.  Influence of ambient and ventilator output temperatures on performance of heated-wire humidifiers. , 2004, American journal of respiratory and critical care medicine.