Experimental investigation into the performance of large-scale earthing electrodes

Analytical and numerical simulation techniques have been developed for the calculation of earth resistance/impedance and to estimate the potential distribution in the vicinity of earth electrodes. However, very little literature is available on experimental validation of these calculation techniques. To address this, a programme of experimental tests on various earth electrodes has been carried out at the lower water reservoir of a hydro pumped-storage power station in North Wales. In this paper, the earthing test facility at Dinorwig power station is described including the details of the experimental set up. The results from experimental tests on a 5mx5m earth grid, immersed in water and energised are under ac, dc and impulse, are presented. The values of measured earth resistance/impedance and water surface potential distributions are compared with those obtained from analytical calculations and detailed numerical computer simulations.

[1]  N.M. Nor,et al.  Characterization of ionization phenomena in soils under fast impulses , 2006, IEEE Transactions on Power Delivery.

[2]  Fermín Navarrina,et al.  A boundary element numerical approach for grounding grid computation , 1999 .

[3]  H. Griffiths,et al.  Determination of threshold electric field E/sub C/ of soil under high impulse currents , 2005, IEEE Transactions on Power Delivery.

[4]  Wallace do Couto Boaventura,et al.  Testing and evaluating grounding systems of high voltage energized substations: alternative approaches , 1999 .

[5]  Dinkar Mukhedkar,et al.  Substation Ground Impedance: Comparative Field Measurements with High and Low Current Injection Methods , 1984, IEEE Power Engineering Review.

[6]  D. Mukhedkar,et al.  Substatiion Ground Impedance: Comparative Field Measurements with High and Low Current Injection Methods , 1984, IEEE Transactions on Power Apparatus and Systems.

[7]  E. Sunde Earth conduction effects in transmission systems , 1949 .

[8]  P. Lipavsky,et al.  Measurement of Ground Potential Difference at Power Substations , 1991, IEEE Power Engineering Review.

[9]  Noureddine Harid,et al.  Characterisation of tower base earthing systems under impulse conditions , 2004 .

[10]  Leonid Grcev,et al.  An electromagnetic model for transients in grounding systems , 1990 .

[11]  J. Sverak,et al.  Simplified Analysis of Electrical Gradients Above a Ground Grid-I How Good Is The Present IEEE Method? (A Special Report For WG 78.1) , 1984, IEEE Transactions on Power Apparatus and Systems.

[12]  A. Haddad,et al.  Large-scale earthing test facilities at Dinorwig power station , 2008, 2008 International Conference on Condition Monitoring and Diagnosis.

[13]  Donald Kasten,et al.  Scale Model Studies of Station Grounding Grids , 1983, IEEE Transactions on Power Apparatus and Systems.

[14]  H. Griffiths,et al.  Performance of earthing systems of low resistivity soils , 2006, IEEE Transactions on Power Delivery.