Computation of HORRAT values.

The formula for the Horwitz ratio (HORRAT) as presented in the Study Director's Manual of AOAC INTERNATIONAL is applicable only when the concentration is in the unit/unit form (e.g., microg/microg, g/g, etc.). When the analyte concentration is a trace or mass fraction amount (e.g., microg/g), the formula generates incorrect HORRAT values. Alternative calculation procedures are presented to circumvent such problems.