Arterial and central venous pressure monitoring.

Pressure monitoring systems influence the contour of the displayed wave-forms and, on occasion, can introduce significant artifact in the pressure traces. It is important to understand the technical details of invasive pressure monitoring to interpret better the information presented. Careful observation of the arterial pressure waveform can provide information about ventricular function, the arterial system, and ventricular preload. In particular, systolic pressure variation during the respiratory cycle in mechanically ventilated patients is a clinically useful indicator of volume status. CVP monitoring is also used to assess intravascular volume, but this measurement is significantly influenced by ventricular compliance and intrathoracic pressure. Under most clinical circumstances, a trend in CVP values or its change with therapeutic maneuvers is more reliable than a single measurement. Like arterial pressure waveforms, CVP waveform morphology can provide important information about clinical pathophysiology.

[1]  R G Wilkins,et al.  Radial artery cannulation and ishaemic damage: a review , 1985, Anaesthesia.

[2]  S. Chauhan,et al.  Femoral artery pressures are more reliable than radial artery pressures on initiation of cardiopulmonary bypass. , 2000, Journal of cardiothoracic and vascular anesthesia.

[3]  S. Laurent,et al.  Arterial alterations with aging and high blood pressure. A noninvasive study of carotid and femoral arteries. , 1993, Arteriosclerosis and thrombosis : a journal of vascular biology.

[4]  J. Marini,et al.  Pulmonary artery occlusion pressure: clinical physiology, measurement, and interpretation. , 2015, The American review of respiratory disease.

[5]  M. O'Rourke,et al.  Wave reflections and the arterial pulse. , 1984, Archives of internal medicine.

[6]  P. Hunziker Accuracy and dynamic response of disposable pressure transducertubing systems , 1987, Canadian journal of anaesthesia = Journal canadien d'anesthesie.

[7]  A. Perel,et al.  Positive end-expiratory pressure-induced hemodynamic changes are reflected in the arterial pressure waveform. , 1996, Critical care medicine.

[8]  J. Timsit,et al.  Central vein catheter-related thrombosis in intensive care patients: incidence, risks factors, and relationship with catheter-related sepsis. , 1998, Chest.

[9]  G. London,et al.  Influence of arterial pulse and reflected waves on blood pressure and cardiac function. , 1999, American heart journal.

[10]  J. Teboul,et al.  Predicting fluid responsiveness in ICU patients: a critical analysis of the evidence. , 2002, Chest.

[11]  M. Haller,et al.  Beat-to-beat measurement of cardiac output by intravascular pulse contour analysis: a prospective criterion standard study in patients after cardiac surgery. , 2000, Journal of cardiothoracic and vascular anesthesia.

[12]  R. Gardner,et al.  Equivalence of fast flush and square wave testing of blood pressure monitoring systems , 1996, Journal of Clinical Monitoring.

[13]  Haim Bitterman,et al.  Central vein catheterization. Failure and complication rates by three percutaneous approaches. , 1986, Archives of internal medicine.

[14]  R M Gardner,et al.  Direct blood pressure measurement--dynamic response requirements. , 1981, Anesthesiology.

[15]  Bruno D. Fornage,et al.  Complications and failures of subclavian-vein catheterization. , 1994 .

[16]  E. Ingenito,et al.  Prevalence of deep venous thrombosis among patients in medical intensive care. , 1995, JAMA.

[17]  J. Brock‐Utne,et al.  Wrist Hyperextension Leads to Median Nerve Conduction Block: Implications for Intra-arterial Catheter Placement , 2004, Anesthesiology.

[18]  Michael K Gould,et al.  Preventing complications of central venous catheterization. , 2003, The New England journal of medicine.

[19]  N. Linton,et al.  Estimation of changes in cardiac output from the arterial blood pressure waveform in the upper limb. , 2001, British journal of anaesthesia.

[20]  J. Mark,et al.  Continuous cardiac output monitoring with pulse contour analysis: A comparison with lithium indicator dilution cardiac output measurement , 2005, Critical care medicine.

[21]  H A Schwid,et al.  The Effect of Graded Hemorrhage and Intravascular Volume Replacement on Systolic Pressure Variation in Humans During Mechanical and Spontaneous Ventilation , 1995, Anesthesia and analgesia.

[22]  S. Franklin,et al.  Measuring hypertensive cardiovascular risk: the vascular overload concept. , 1994, American heart journal.

[23]  M. Karamanoglu A system for analysis of arterial blood pressure waveforms in humans. , 1997, Computers and biomedical research, an international journal.

[24]  C. Vlachopoulos,et al.  Pressure-Altering Agents Affect Central Aortic Pressures More Than Is Apparent From Upper Limb Measurements in Hypertensive Patients: The Role of Arterial Wave Reflections , 2001, Hypertension.

[25]  T. Dorman,et al.  Radial artery pressure monitoring underestimates central arterial pressure during vasopressor therapy in critically ill surgical patients. , 1998, Critical care medicine.

[26]  Jean-Yves Lefrant,et al.  Complications of Femoral and Subclavian Venous Catheterization in Critically Ill Patients: A Randomized Controlled Trial , 2001 .

[27]  Mangano Dt,et al.  Ischemic injury following uncomplicated radial artery catheterization. , 1979 .

[28]  B. Reichart,et al.  Continuous cardiac output by femoral arterial thermodilution calibrated pulse contour analysis: comparison with pulmonary arterial thermodilution. , 1999, Critical care medicine.

[29]  R. Gardner,et al.  The fast flush test measures the dynamic response of the entire blood pressure monitoring system. , 1992, Anesthesiology.

[30]  A. Perel,et al.  Systolic Blood Pressure Variation is a Sensitive Indicator of Hypovolemia in Ventilated Dogs Subjected to Graded Hemorrhage , 1986, Anesthesiology.

[31]  L. Mermel,et al.  Prevention of Central Venous Catheter-Related Bloodstream Infection by Use of an Antiseptic-Impregnated Catheter , 1997, Annals of Internal Medicine.

[32]  A. Keats,et al.  On the Safety of Radial Artery Cannulation , 1983 .

[33]  B. Kleinman Understanding natural frequency and damping and how they relate to the measurement of blood pressure , 1989, Journal of Clinical Monitoring.

[34]  A G Randolph,et al.  Ultrasound guidance for placement of central venous catheters: a meta-analysis of the literature. , 1996, Critical care medicine.

[35]  W. Runciman,et al.  Experimental analysis of catheter-manometer systems in vitro and in vivo. , 1989, Anesthesiology.

[36]  P. Ludbrook,et al.  Anatomically and physiologically based reference level for measurement of intracardiac pressures. , 1995, Circulation.

[37]  M. Mandel,et al.  Radial artery cannulation and complications in 1,000 patients: Precautions , 1977 .

[38]  Jonathan B. Mark,et al.  Atlas of Cardiovascular Monitoring , 1997 .

[39]  D. Amar,et al.  Correlation of peripheral venous pressure and central venous pressure in surgical patients. , 2001, Journal of cardiothoracic and vascular anesthesia.

[40]  J. Vincent,et al.  Expert Panel: The use of the pulmonary artery catheter , 1991, Intensive Care Medicine.

[41]  Didier Pittet,et al.  Nosocomial bloodstream infection in critically ill patients. Excess length of stay, extra costs, and attributable mortality. , 1994, JAMA.

[42]  R. K. Webb,et al.  Problems Associated with Vascular Access: An Analysis of 2000 Incident Reports , 1993, Anaesthesia and intensive care.

[43]  Howard A. Schwid,et al.  Frequency response evaluation of radial artery catheter-manometer systems: Sinusoidal frequency analysis versus flush method , 1988, Journal of Clinical Monitoring.

[44]  R. Deane,et al.  The dynamic responses of liquid-filled catheter systems for direct measurements of blood pressure. , 1980, Anesthesiology.