Robust automatic segmentation of multiple implanted cylindrical gold fiducial markers in cone-beam CT projections.

PURPOSE Implanted fiducial markers, which are used to correct for day-to-day variations, may potentially also be used to correct for intrafraction motion measurements. However, before any treatment can make use of, and react to, the position of the inserted markers they have to be segmented, either manually through expert user intervention or automatically from an imaging system. In the current study, we aimed to establish a robust and autonomous segmentation method for implanted cylindrical gold markers in a single set of projections from a cone-beam computed tomography (CBCT). METHODS Multiple cylindrical gold markers were segmented in the projection images of CBCT scans by five sequential steps. Initially, marker candidates were identified in all projections with a blob detection routine, and then traced in subsequent projections. Traces inconsistent with a 3D marker position were rejected, and the best remaining traces were identified and used for the construction of a 3D marker constellation model, consisting of the size, position and orientation of the markers. Finally, projections of the model were used to generate templates for the final template-based marker segmentation. Hereby, challenging situations such as overlap of markers and low contrast regions were taken into account. The segmentation method was tested in 63 CBCT scans from 11 patients with 2-4 cylindrical gold markers implanted in the prostate and for 62 CBCT scans from six patients each with 2-3 cylindrical gold markers implanted in the liver and up to two cylindrical markers placed externally on the abdomen. After segmentation all projections of the 125 scans were manually inspected, and a successful segmentation was registered if the segmented position was within the projection of the marker. RESULTS For prostate markers, the segmentation was successful in 99.8% of the projections. For the liver patients, liver markers and external markers were segmented successfully in 99.9 and 99.8% of the projections, respectively. All markers were identified in the 3D marker constellation model. The most common source of segmentation error was low contrast and motion of markers relative to each other, which resulted in a discrepancy between the template and actual projection appearance during marker overlap. Markers were overlapping in 20, 2.7, and 0.1% of the projections for prostate, liver, and external, respectively. CONCLUSIONS We have successfully implemented a new method that, without prior knowledge on marker size, position, orientation, and number, autonomously segments cylindrical gold markers from CBCT projections with a high success rate, despite overlap, motion, and low contrast.

[1]  K. Langen,et al.  Organ motion and its management. , 2001, International journal of radiation oncology, biology, physics.

[2]  W Mao,et al.  Fast internal marker tracking algorithm for onboard MV and kV imaging systems. , 2008, Medical physics.

[3]  Paul J Keall,et al.  Implementation of a new method for dynamic multileaf collimator tracking of prostate motion in arc radiotherapy using a single kV imager. , 2010, International journal of radiation oncology, biology, physics.

[4]  Steve B. Jiang,et al.  Fluoroscopic tracking of multiple implanted fiducial markers using multiple object tracking , 2007, Physics in medicine and biology.

[5]  Emma J Harris,et al.  Feasibility of fully automated detection of fiducial markers implanted into the prostate using electronic portal imaging: a comparison of methods. , 2006, International journal of radiation oncology, biology, physics.

[6]  Paul J Keall,et al.  A method to estimate mean position, motion magnitude, motion correlation, and trajectory of a tumor from cone-beam CT projections for image-guided radiotherapy. , 2008, International journal of radiation oncology, biology, physics.

[7]  Lei Xing,et al.  A fiducial detection algorithm for real-time image guided IMRT based on simultaneous MV and kV imaging. , 2008, Medical physics.

[8]  Jerry L Prince,et al.  Automatic segmentation of radiographic fiducial and seeds from X-ray images in prostate brachytherapy. , 2012, Medical engineering & physics.

[9]  Ziv Yaniv Localizing spherical fiducials in C-arm based cone-beam CT. , 2009, Medical physics.

[10]  Jan J W Lagendijk,et al.  Measurements and clinical consequences of prostate motion during a radiotherapy fraction. , 2002, International journal of radiation oncology, biology, physics.

[11]  Qiuwen Wu,et al.  Prostate intrafraction motion evaluation using kV fluoroscopy during treatment delivery: a feasibility and accuracy study. , 2008, Medical physics.

[12]  Jeroen Hermans,et al.  Fast, accurate, and robust automatic marker detection for motion correction based on oblique kV or MV projection image pairs. , 2010, Medical physics.

[13]  Paul J Keall,et al.  A method for robust segmentation of arbitrarily shaped radiopaque structures in cone-beam CT projections. , 2011, Medical physics.

[14]  Marco van Vulpen,et al.  Analysis of fiducial marker-based position verification in the external beam radiotherapy of patients with prostate cancer. , 2007, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[15]  Ross Berbeco,et al.  Automatic marker detection and 3D position reconstruction using cine EPID images for SBRT verification. , 2009, Medical physics.

[16]  R. Mohan,et al.  On the use of EPID-based implanted marker tracking for 4D radiotherapy. , 2004, Medical physics.