Integrated protection scheme for power line

This paper presents an integrated relay and its associated protection scheme for power transmission lines. The concept of integrated protection is firstly introduced, in which a centralized protection system or relay provides the protection for multiple power plants or a substation. A novel integrated protection relay based on the combination of a number of protection principles is described. In the proposed scheme, the specially designed protection relays are installed at each substation of a network and are responsible for the protection of every line section connected to the substation busbar. The combined algorithms with multiple settings are implemented into the relay to cover all the protected line sections. Simulation studies show that the proposed protection scheme is able to produce desirable performance and may offer many advantages over the existing one and great potential for future applications.

[1]  Yang Qi-xun Technical Development and Analysis on Modern Microprocessor-based Protection , 2003 .

[2]  Xinzhou Dong,et al.  Non-communication protection for radial connected distribution systems , 2004 .

[3]  X.Z. Dong,et al.  Application of percentage cross differential relay in EHV double lines , 2005, 2005 IEEE Russia Power Tech.

[4]  Z.Q. Bo,et al.  Application of Transient Polarity Comparison Technique to Power System Protection , 2005, 2005 IEEE/PES Transmission & Distribution Conference & Exposition: Asia and Pacific.

[5]  M. S. Sachdev,et al.  Generator Differential Protection Using a Hybrid Computer , 1973 .

[6]  A.M. Ranjbar,et al.  An improved method for the digital protection of high voltage transmission lines , 1975, IEEE Transactions on Power Apparatus and Systems.

[7]  M C Meyer,et al.  The application of an artificial neural network and pharmacokinetic simulations in the design of controlled-release dosage forms. , 1999, Journal of controlled release : official journal of the Controlled Release Society.

[8]  Zhiqian Bo,et al.  Development of non-communication relays for transmission and distribution systems , 2004 .

[9]  Armando Guzmán,et al.  Integrated Transformer, Feeder, and Breaker Protection: An Economic and Reliable Solution for Distribution Substations , 2000 .

[10]  P. McLaren,et al.  Fourier-series techniques applied to distance protection , 1975 .

[11]  I. F. Morrison,et al.  Digital Calculation of Impedance for Transmission Line Protection , 1971 .

[12]  Zhao Yang Dong,et al.  Non-communication protection of distribution feeders with tapped-off-loads , 2002, Proceedings. International Conference on Power System Technology.

[13]  He Ben-teng TRANSMISSION LINE AGGREGATE PROTECTION AND ITS IMPLEMENTATION , 2005 .

[14]  G. D. Rockefeller,et al.  Fault Protection with a Digital Computer , 1969 .

[15]  Xinzhou Dong,et al.  Evaluation of an Accelerated Overcurrent Protection for Single Circuit Breaker Distribution Feeder , 2005, 2005 IEEE/PES Transmission & Distribution Conference & Exposition: Asia and Pacific.

[16]  Xinzhou Dong,et al.  An New Directional Comparison Scheme for Distribution Line Protection , 2006, Proceedings of the 41st International Universities Power Engineering Conference.

[17]  G. Weller,et al.  Positional protection of transmission systems using Global Positioning System , 2000 .