Inertial and frictional influences of instrumented wheelchair wheels

Background Instrumented wheelchair wheels can be used to study the kinematics and kinetics of manual wheelchair propulsion. The objective of this study was to evaluate the impact of instrumented wheels on the inertial and frictional parameters of a wheelchair system. Methods This study compared mechanical parameters of an ultralightweight rigid frame wheelchair configured with pairs of SMARTwheels and spoke pneumatic wheels and loaded with an ISO 75 kg wheelchair dummy. Rectilinear and turning inertia of the occupied wheelchair and the rotational inertia of drive wheels were measured. A coast-down test measured frictional energy loss during straight and turning trajectories. Findings The addition of instrumented wheels increased occupied system mass by about 6% and turning inertia by about 16%. Frictional energy loss increased by over 40% in a straight trajectory and over 30% during turning. Interpretation Addition of instrumented increased the inertia and frictional energy loss of the wheelchair system. These relative effects will impact the wheelchair operator and increase the instantaneous propulsion torque during wheelchair maneuvers. The impacts will be less under conditions involving little or no change in velocity. Researchers should be encouraged to report changes in mass and weight distribution induced by addition of instrumented wheelchair wheels.

[1]  W M Richter The effect of seat position on manual wheelchair propulsion biomechanics: a quasi-static model-based approach. , 2001, Medical engineering & physics.

[2]  Stephen Sprigle,et al.  Evaluation of wheelchair resistive forces during straight and turning trajectories across different wheelchair configurations using free-wheeling coast-down test. , 2015, Journal of rehabilitation research and development.

[3]  Megan K. MacGillivray,et al.  Relationships between wheeling parameters and wheelchair skills in adults and children with SCI , 2015, Spinal Cord.

[4]  Fausto O. Medola,et al.  Partitioning Kinetic Energy During Freewheeling Wheelchair Maneuvers , 2014, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[5]  R.A. Cooper,et al.  SMART/sup Wheels/: development and testing of a system for measuring manual wheelchair propulsion dynamics , 1993, IEEE Transactions on Biomedical Engineering.

[6]  Stephen Sprigle,et al.  Test method for empirically determining inertial properties of manual wheelchairs. , 2012, Journal of rehabilitation research and development.

[7]  Danian Liu,et al.  A new trifilar pendulum approach to identify all inertia parameters of a rigid body or assembly , 2009 .

[8]  B. Sawatzky,et al.  Test-retest reliability and minimal detectable change of the SmartWheel clinical protocol. , 2012, Archives of physical medicine and rehabilitation.

[9]  Joseph Bascou,et al.  A method for the field assessment of rolling resistance properties of manual wheelchairs , 2013, Computer methods in biomechanics and biomedical engineering.

[10]  Jeffrey T. Turner,et al.  Comparing handrim biomechanics for treadmill and overground wheelchair propulsion , 2010, Spinal Cord.

[11]  Stephen Sprigle,et al.  Changes in inertia and effect on turning effort across different wheelchair configurations. , 2013, Journal of rehabilitation research and development.

[12]  Weerawat Limroongreungrat,et al.  An Instrumented Wheel System for Measuring 3-D Pushrim Kinetics During Racing Wheelchair Propulsion , 2009, Research in sports medicine.