A Wireless Handheld Pressure Measurement System for In Vivo Monitoring of Intraocular Pressure in Rabbits

Intraocular pressure (IOP) is the leading modifiable risk factor for preventing vision loss in glaucoma patients. Direct and frequent IOP measurements are highly desirable to assess adequacy of treatment and prevent further vision loss. In this study, we report on successful in vivo measurements of intraocular pressure in rabbits using an optical IOP measurement system. The sensor was implanted during cataract surgery in two New Zealand white (NZW) rabbits and tested in vivo for ten weeks. Prior to implantation, the sensors were characterized in vitro in the physiologically relevant pressure range of 0–60 mmHg. A portable wireless handheld reader consisting of an internal beam splitter, a monochromatic light source, and a digital single-lens reflex (DSLR) camera was also designed and implemented to capture interference patterns from the sensor. The sensitivity and accuracy of the sensor was 30 nm/mmHg and ±0.2 mmHg, respectively. Ten weeks post-implantation, the two NZW rabbits continued to respond well to the implant with no observable inflammation, signs of infection, or biofouling. All IOP measurements were obtained using the portable DSLR handheld reader. Successful in vivo studies demonstrate biocompatibility of the IOP sensor and prove feasibility of the IOP measurement system. The system has the potential to be used in both clinical and patient point-of-care (home) settings to frequently and accurately measure pressure.

[1]  W M Bourne,et al.  Increased corneal thickness in patients with ocular hypertension. , 2001, Archives of ophthalmology.

[2]  T. Wong,et al.  Global prevalence of glaucoma and projections of glaucoma burden through 2040: a systematic review and meta-analysis. , 2014, Ophthalmology.

[3]  Robert Edward Ang,et al.  The Small-Aperture IC-8 Intraocular Lens: A New Concept for Added Depth of Focus in Cataract Patients. , 2015, American journal of ophthalmology.

[4]  S. Quake,et al.  An implantable microfluidic device for self-monitoring of intraocular pressure , 2014, Nature Medicine.

[5]  Eberhard Spoerl,et al.  Age-dependent correction factors for goldmann tonometry. , 2012, Journal of glaucoma.

[6]  A. Aref,et al.  The Sensimed Triggerfish contact lens sensor: efficacy, safety, and patient perspectives , 2017, Clinical ophthalmology.

[7]  Jeong Oen Lee In vivo intraocular pressure measurements using a miniaturized nanophotonics-enhanced sensor implant , 2016, 2016 Progress in Electromagnetic Research Symposium (PIERS).

[8]  Yi-Chun Shih,et al.  Packaging for a wireless intraocular pressure sensor with a solder-filled microchannel antenna , 2012, 2012 IEEE 25th International Conference on Micro Electro Mechanical Systems (MEMS).

[9]  Janet Leasher,et al.  Number of People Blind or Visually Impaired by Glaucoma Worldwide and in World Regions 1990 – 2010: A Meta-Analysis , 2016, PloS one.

[10]  Robert N. Weinreb,et al.  Optical intraocular pressure measurement system for glaucoma management , 2017, 2017 IEEE Healthcare Innovations and Point of Care Technologies (HI-POCT).

[11]  Rohit Varma,et al.  Implantable micromechanical parylene-based pressure sensors for unpowered intraocular pressure sensing , 2007 .

[12]  Frank E. Talke,et al.  Optimization of an Interferometric Pressure Sensor for Intraocular Pressure Measurements , 2018, ASME-JSME 2018 Joint International Conference on Information Storage and Processing Systems and Micromechatronics for Information and Precision Equipment.

[13]  J. Giaconi,et al.  Glaucomas: Glaucoma and the Cornea , 2010 .

[14]  Arthur L. Chlebowski,et al.  A Miniature-Implantable RF-Wireless Active Glaucoma Intraocular Pressure Monitor , 2010, IEEE Transactions on Biomedical Circuits and Systems.

[15]  Benjamin Mottet,et al.  Effect of overnight wear of the Triggerfish® sensor on corneal thickness measured by Visante® anterior segment optical coherence tomography , 2014, Acta ophthalmologica.

[16]  Frank E. Talke,et al.  Design of an Optical Pressure Measurement System for Intraocular Pressure Monitoring , 2018, IEEE Sensors Journal.

[17]  N. Chronis,et al.  A Near-Infrared Optomechanical Intracranial Pressure Microsensor , 2012, Journal of Microelectromechanical Systems.

[18]  J. Diamond,et al.  24-Hour Monitoring of Intraocular Pressure in Glaucoma Management: A Retrospective Review , 2003, Journal of glaucoma.

[19]  Leonard K. Seibold,et al.  The diurnal and nocturnal effects of travoprost in normal-tension glaucoma , 2014, Clinical ophthalmology.

[20]  J. Morrison,et al.  Glaucoma: Science and Practice , 2002 .

[21]  Chaker Ben Salem,et al.  Glaucoma , 2018, The Lancet.

[22]  M. Kass,et al.  Normal-pressure glaucoma. , 1998, American journal of ophthalmology.

[23]  B.J. Hosticka,et al.  A programmable intraocular CMOS pressure sensor system implant , 2001, Proceedings of the 26th European Solid-State Circuits Conference.

[24]  Iqbal Ike K Ahmed,et al.  Malignant glaucoma after cataract surgery , 2014, Journal of cataract and refractive surgery.

[25]  H Goldmann,et al.  Open-angle glaucoma. , 1972, The British journal of ophthalmology.

[26]  M.S. Humayun,et al.  Microfabricated Implantable Parylene-Based Wireless Passive Intraocular Pressure Sensors , 2008, Journal of Microelectromechanical Systems.

[27]  Katrin Sternberg,et al.  Suitability and calibration of a rebound tonometer to measure IOP in rabbit and pig eyes. , 2011, Veterinary ophthalmology.

[28]  Haoyu Chen,et al.  Repeatability, reproducibility and agreement of intraocular pressure measurement in rabbits by the TonoVet and Tono-Pen , 2016, Scientific Reports.

[29]  Albert Hofman,et al.  Lifestyle and risk of developing open-angle glaucoma: the Rotterdam study. , 2011, Archives of ophthalmology.

[30]  M. C. Leske,et al.  Fluctuation of intraocular pressure and glaucoma progression in the early manifest glaucoma trial. , 2007, Ophthalmology.

[31]  M. Erdurmuş,et al.  Dynamic contour tonometer versus goldmann applanation tonometer. , 2006, Journal of glaucoma.

[32]  N. Chronis,et al.  A powerless optical microsensor for monitoring intraocular pressure with keratoprostheses , 2013, 2013 Transducers & Eurosensors XXVII: The 17th International Conference on Solid-State Sensors, Actuators and Microsystems (TRANSDUCERS & EUROSENSORS XXVII).

[33]  Ellis Meng,et al.  Chronically Implanted Pressure Sensors: Challenges and State of the Field , 2014, Sensors.

[34]  R. Weinreb,et al.  Continuous 24-hour intraocular pressure monitoring for glaucoma--time for a paradigm change. , 2012, Swiss medical weekly.

[35]  Wilfried Mokwa,et al.  Medical implants based on microsystems , 2007 .

[36]  Jeong-Bong (JB) Lee,et al.  A SU-8-Based Microfabricated Implantable Inductively Coupled Passive RF Wireless Intraocular Pressure Sensor , 2012, Journal of Microelectromechanical Systems.

[37]  Shunsuke Nakakura,et al.  Icare® rebound tonometers: review of their characteristics and ease of use , 2018, Clinical ophthalmology.

[38]  Farzana Jahan,et al.  Twenty-four hour intraocular pressure monitoring with the SENSIMED Triggerfish contact lens: effect of body posture during sleep , 2017, British Journal of Ophthalmology.

[39]  Hyuck Choo,et al.  Intraocular Sensors: Biocompatible Multifunctional Black-Silicon for Implantable Intraocular Sensor (Adv. Healthcare Mater. 4/2017) , 2017 .

[40]  A. Bleau,et al.  Managing Intraocular Pressure: Innovation in Glaucoma Management , 2016 .

[41]  D. Hodge,et al.  Long-term trends in glaucoma-related blindness in Olmsted County, Minnesota. , 2014, Ophthalmology.

[42]  Yu-Chong Tai,et al.  Spiral-tube parylene intraocular pressure sensor , 2005, 18th IEEE International Conference on Micro Electro Mechanical Systems, 2005. MEMS 2005..

[43]  R Chaudhary,et al.  First postoperative day intraocular pressure rise in resident-performed cataract surgery , 2012, Eye.

[44]  Wilfried Mokwa,et al.  Micro-transponder systems for medical applications , 2001, IEEE Trans. Instrum. Meas..

[45]  W PATTERSON,et al.  What Is Glaucoma? , 2015, Perspectives in biology and medicine.

[46]  David C. Herman,et al.  Blindness and glaucoma: Comparison of patient conditions progressing to blindness from glaucoma with patients maintaining vision , 2003 .

[47]  H A Quigley,et al.  Glaucoma in China (and worldwide): changes in established thinking will decrease preventable blindness , 2001, The British journal of ophthalmology.

[48]  Guangqiang Jiang,et al.  Design Challenges of Implantable Pressure Monitoring System , 2010, Front. Neuropro..

[49]  H-S Philip Wong,et al.  Continuous wireless pressure monitoring and mapping with ultra-small passive sensors for health monitoring and critical care , 2014, Nature Communications.

[50]  J. Crowston,et al.  Validation of rebound tonometry for intraocular pressure measurement in the rabbit. , 2014, Experimental eye research.