Automatical Intima-Media Border Segmentation on Ultrasound Image Sequences Using a Kalman Filter Snake

Segmentation of carotid intima-media (IM) borders from ultrasound images is of great importance for predicting cardiovascular risks. In this paper, we have developed a fully automatic approach to sequentially segment the carotid IM borders in each image throughout ultrasound sequences. First, the first frame of an ultrasound sequence is automatically segmented using edge detectors and dynamic programming, and then the rest frames are segmented successively under the state-space framework. Under this framework, we developed a variant of the snake method for a precise measurement. The evaluation of our segmentation result is done by comparison with average manual delineations of three physicians on a total of 65 sequences. The accuracy of our method is high. (Segmentation error is <inline-formula> <tex-math notation="LaTeX">$32.1~\pm ~37.5~\mu \text{m}$ </tex-math></inline-formula> for LI and <inline-formula> <tex-math notation="LaTeX">$35.0~\pm ~41.5~{\mu }\text{m}$ </tex-math></inline-formula> for MA.) The BA plot and the linear regression also demonstrate that our method is in agreement with the ground truth. This paper strengthens the potential of the state-space and snake-based approach in segmenting IM borders for clinical diagnosis by demonstrating a fully automatic scheme.

[1]  Cheng Wang,et al.  New method of vessel centerline extraction from 3D CT coronary angiography based on open-snake , 2015 .

[2]  Dong Liang,et al.  Motion Tracking of the Carotid Artery Wall From Ultrasound Image Sequences: a Nonlinear State-Space Approach , 2018, IEEE Transactions on Medical Imaging.

[3]  K. Seung,et al.  Visualization of coronary atherosclerotic plaques in patients using optical coherence tomography: comparison with intravascular ultrasound. , 2002, Journal of the American College of Cardiology.

[4]  IngerWendelhag,et al.  A New Automated Computerized Analyzing System Simplifies Readings and Reduces the Variability in Ultrasound Measurement of Intima-Media Thickness , 1997 .

[5]  N. David Yanez,et al.  Changes in Carotid Intima-Media Thickness During the Cardiac Cycle: The Multi-Ethnic Study of Atherosclerosis , 2012, Journal of the American Heart Association.

[6]  Huafeng Liu,et al.  SIMULTANEOUS RECOVERY OF LEFT VENTRICULAR MOTION AND INPUT FORCES FROM MEDICAL IMAGE SEQUENCES , 2007, 2007 4th IEEE International Symposium on Biomedical Imaging: From Nano to Macro.

[7]  Jianwen Luo,et al.  Robust Segmentation of Intima–Media Borders With Different Morphologies and Dynamics During the Cardiac Cycle , 2018, IEEE Journal of Biomedical and Health Informatics.

[8]  Heye Zhang,et al.  Robust estimation of carotid artery wall motion using the elasticity‐based state‐space approach , 2017, Medical Image Anal..

[9]  Tomas Gustavsson,et al.  A new method based on dynamic programming for boundary detection in ultrasound image sequences , 2008, 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[10]  R. Malik,et al.  Carotid intima–media thickness: ultrasound measurement, prognostic value and role in clinical practice , 2012, Postgraduate Medical Journal.

[11]  Hans Burkhardt,et al.  Automatic detection of the intimal and the adventitial layers of the common carotid artery wall in ultrasound B-mode images using snakes , 1999, Proceedings 10th International Conference on Image Analysis and Processing.

[12]  Dan Simon,et al.  Optimal State Estimation: Kalman, H∞, and Nonlinear Approaches , 2006 .

[13]  João Manuel R. S. Tavares,et al.  A novel automatic algorithm for the segmentation of the lumen of the carotid artery in ultrasound B-mode images , 2013, Expert Syst. Appl..

[14]  Carlos Manterola,et al.  Grosor de la Íntima-media Carotídea como Predictor de Evento Cardiovascular: Revisión Sistemática de la Literatura , 2013 .

[15]  Jiankang Wang,et al.  Guiding ziplock snakes with a priori information , 2003, IEEE Trans. Image Process..

[16]  Yuan Zhou,et al.  Ultrasound intima-media segmentation using Hough transform and dual snake model , 2012, Comput. Medical Imaging Graph..

[17]  M. Szklo,et al.  Associations of Coronary Heart Disease with Common Carotid Artery Near and Far Wall Intima-Media Thickness: The Multi-Ethnic Study of Atherosclerosis. , 2015, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[18]  Jasjit S. Suri,et al.  A state of the art review on intima-media thickness (IMT) measurement and wall segmentation techniques for carotid ultrasound , 2010, Comput. Methods Programs Biomed..

[19]  Y. Duan,et al.  Evaluation of carotid artery elasticity changes in patients with type 2 diabetes , 2014, Cardiovascular Diabetology.

[20]  Yuan Zhou,et al.  Dynamic programming in parallel boundary detection with application to ultrasound intima-media segmentation , 2013, Medical Image Anal..

[21]  Juan Morales-Sánchez,et al.  Automatic detection of the intima-media thickness in ultrasound images of the common carotid artery using neural networks , 2013, Medical & Biological Engineering & Computing.

[22]  F. Faita,et al.  Real‐time Measurement System for Evaluation of the Carotid Intima‐Media Thickness With a Robust Edge Operator , 2008, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[23]  Milan Sonka,et al.  Image Processing, Analysis and Machine Vision , 1993, Springer US.

[24]  U. Rajendra Acharya,et al.  Completely Automated Multiresolution Edge Snapper—A New Technique for an Accurate Carotid Ultrasound IMT Measurement: Clinical Validation and Benchmarking on a Multi-Institutional Database , 2012, IEEE Transactions on Image Processing.

[25]  B. Balkau,et al.  Noninvasive measurement of carotid extra-media thickness: associations with cardiovascular risk factors and intima-media thickness. , 2009, JACC. Cardiovascular imaging.

[26]  Aurélio J. C. Campilho,et al.  Automatic detection of the carotid lumen axis in B-mode ultrasound images , 2014, Comput. Methods Programs Biomed..

[27]  U. Rajendra Acharya,et al.  Constrained snake vs. conventional snake for carotid ultrasound automated IMT measurements on multi-center data sets. , 2012, Ultrasonics.

[28]  Guillaume Zahnd,et al.  A Fully-Automatic Method to Segment the Carotid Artery Layers in Ultrasound Imaging: Application to Quantify the Compression-Decompression Pattern of the Intima-Media Complex During the Cardiac Cycle. , 2017, Ultrasound in medicine & biology.

[29]  J. Stein,et al.  Carotid intima-media thickness, plaques, and cardiovascular disease risk: implications for preventive cardiology guidelines. , 2010, Journal of the American College of Cardiology.

[30]  Demetri Terzopoulos,et al.  Snakes: Active contour models , 2004, International Journal of Computer Vision.